When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopy

Abstract

Registering a segmented CT to fluoroscopy can locate every fracture fragment but can guide surgery only when trusted. After each shot, our closed loop registers all fragments, bounds their errors with a calibrated sandwich covariance, flags implausible or ambiguous ones, and stops or plans the next view. On simulated fluoroscopy of 60 held-out fracture CTs with realistic image uncertainty, 95% bounds covered 83% of unflagged fragments and 91% of those within 5mm, but from the second view on 14% failed by over 5mm, a third with bounds of at most 2mm. A fragment's shift when a view was added separated tightly bounded failures best (exploratory; AUC 0.94, bound 0.81). Requiring that the newest view moved no fragment beyond its bound, preferred post hoc, lowered false stops at 2mm from 23% to 6% overall, with 345 instead of 362 correct ones but more trajectories uncertified; delaying the stop did not, and other signals at equal acceptance left 10-15% false. With a segmentation error shared by all views (median Dice 0.89), 21% of this rule's stops were false against 10% without it (15 cases; exploratory). Minimax planning certified sooner than the clinical protocol without the check (4.20 versus 4.72 shots, Holm p <0.001), but no criterion reached the pre-specified endpoint, a true 2mm error, significantly sooner, even in the true basin. On real fluoroscopy of five intact pelves no 2mm certificate was false. Trust takes evidence across views, not only a calibrated local bound.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bowen Xiang. 2026-11-12. When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopy. https://searcharxiv.com/abs/2611.05618

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Searcharxiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Physics-Aware Zero-Shot Learning for Low-Dose CT from a Single Sinogram

Low-dose computed tomography (CT) imaging remains a persistent challenge, especially under heterogeneous acquisition conditions. Zero-shot learning, which enables models to learn directly from individual images without external supervision, represents a compelling approach to mitigate distribution mismatches arising from variations in scanner hardware, imaging protocols, and patient demographics. However, most existing zero-shot approaches employ down-sampling operations that reduce spatial resolution and cause domain shifts, which become particularly evident when applied to raw sinogram data. Here, we propose a physics-aware zero-shot CT denoising framework to exploit the conjugate symmetry property intrinsic to CT sinograms. Conjugate X-ray pencil beams traverse identical anatomical paths and ideally yield the same expected attenuation values but with independent noise realizations. By randomly mapping sinogram values between conjugate-ray pairs, we synthesize structurally consistent yet noise-diverse sinogram pairs, enabling self-supervised network training without external data. The resulting lightweight denoising network demonstrates strong generalization across low-dose simulation, clinical helical CT, and preclinical photon-counting CT datasets. Quantitative and qualitative results demonstrate competitive denoising performance, with favorable noise suppression and structural preservation across diverse acquisition settings. This work establishes a generalizable and data-efficient paradigm for CT denoising that integrates physical redundancy into learning-based image reconstruction. The code for the proposed method is openly available at: https://github.com/shiyongyi/Physics-Aware-Zero-Shot-CT-Sinogram-Denoising

eess.IV↗

QUTCC: Quantile Uncertainty Training and Conformal Calibration for Imaging Inverse Problems

While deep learning offers tremendous promise for scientific and medical imaging, any failures and hallucinations (predictions that do not coincide with reality) are hard to pinpoint and can have serious downstream consequences. Uncertainty estimation techniques, such as conformal prediction, can help by predicting statistically valid error bars for a model's prediction. However, popular conformal prediction methods were not designed for high-dimensional image-valued problems and do not take into account spatial correlations within an image during conformal calibration, resulting in larger-than-necessary uncertainty intervals. We propose a practical simultaneous quantile regression method that enables non-linear, spatially-adaptive scaling during conformal calibration. Our method, QUTCC uses a U-Net architecture with a quantile embedding to learn a full conditional quantile distribution during training, and then leverages this non-linear, learned function for spatially-adaptive conformal calibration. At test time, our method can efficiently estimate uncertainty intervals with pixel-marginal coverage guarantees. In addition, QUTCC can also predict pixel-wise conditional probability density estimates without any built-in distributional assumptions. We evaluate our method on several denoising problems, accelerated magnetic resonance imaging, and quantitative phase microscopy. Our method consistently produces tighter uncertainty intervals than prior conformal methods at the same coverage level, can predict plausible conditional distributions for different tasks, and in some cases, high-uncertainty regions can help us locate hallucinations in a model's prediction.

eess.IV↗

GroundGazer: An optical reference system for planar localization with millimeter accuracy at low cost

Highly accurate indoor localization systems with absolute mm positioning accuracy are currently expensive. They include laser trackers, total stations, and motion capture systems relying on multiple high-end cameras. In this work, we introduce a high-accuracy, planar indoor localization system named GroundGazer (GG) for autonomous mobile robots (AMRs). GG estimates the AMR's planar position with mm and its heading with sub-degree accuracy. The system requires only a monocular (fisheye) camera, a chessboard floor, and an optional laser diode. Our system is simple and low-cost due to the chessboard floor, robust, scalable to multiple robots, and extendable to 3D position and orientation estimation.

eess.IV↗