Searcharxiv⌕ Search

arXiv · 2611.18773

Amortized conditional inference under changing parameter information in small-angle X-ray scattering

Abstract

Many scientific measurements do not uniquely determine the physical system that produced them. Different parameter configurations may explain the same observations, and additional measurements or physical assumptions can change which explanations remain plausible. We develop an amortized conditional inference method to examine these alternatives as the available information changes. Using masked flow matching, the method approximates joint conditional posteriors when different parameters are supplied exactly or with uncertainty. This allows repeated analysis of the same measurement without retraining, while reusing its encoded representation. We can also examine the consequences of assumed parameter distributions and separately assess whether supplied information is compatible with the observation-only posterior. We validate the learned conditionals against analytic posteriors and compare posterior accuracy and inference cost in a simulated scattering benchmark, where the compressed architecture performs better than joint attention on both measures. We apply the method to small-angle X-ray scattering (SAXS) of cellulose fibrils in paper, examining structural ambiguities in simulated measurements and the effects of physical assumptions on experimental measurements of a paper during hydration. At high humidity, the inferred effective fibril size distribution broadens. Assuming that this distribution remains unchanged instead shifts the posterior towards increased interfibrillar separation, although both interpretations reproduce the measured curves similarly. The compatibility analysis identifies conserved parameter values that are difficult to reconcile with the wettest measurements.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Maria Bånkestad, Sandra Barman, Erik Kaunisto, Eskil Andreasson, Smita Chakraborty, Shun Yu, Jerk Rönnols, Sepideh Pashami. 2026-11-12. Amortized conditional inference under changing parameter information in small-angle X-ray scattering. https://searcharxiv.com/abs/2611.18773

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Searcharxiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

A Paired Monte Carlo Intensity-Ratio Method for Incorporating Detector Resolution in Amplitude Analysis

Finite detector resolution can bias resonance parameters and fit fractions extracted from amplitude analyses. We present the paired Monte Carlo intensity-ratio method for incorporating resolution effects into amplitude analysis. The method uses ratios of reference intensities evaluated at paired truth-level and reconstructed kinematics to reweight the Monte Carlo normalization and approximately account for detector resolution. A resampling study of simulated $D^+\to K^+π^+π^-π^0$ decays shows that the method substantially reduces resolution-induced shifts in fitted resonance widths. Likelihood evaluation uses intensity calculations and normalization sums, avoiding a response convolution at each data event.

physics.data-an↗

Distinguishing thyroid nodule malignancy using digital palpation

Accurate pre-operative diagnosis of thyroid nodules remains a major clinical challenge. Current diagnostic techniques rely on fine-needle aspiration and demonstrate high rates of inconclusive results, often leading to avoidable thyroidectomies with lifelong implications. Here, we introduce a mechanics-based diagnostic method that leverages Digital Palpation to determine malignancy and identify tissue subtypes in human thyroid nodules. From a cohort of patients undergoing thyroidectomies, we evaluated ex vivo thyroid specimens and processed the resulting mechanical data from 36 tests in 10 thyroid nodules. Principal Component Analysis reveals that these experimental results are distributed within a three-dimensional space of interpretable scalar features reflecting tissue grittiness, strength, and toughness, which map closely to descriptions of malignant and benign nodules given by clinicians. Our results further demonstrate that malignant nodules exhibit distinct mechanical signatures compared to their benign counterparts. This revealed a statistically significant difference (p = 9 x 10^-4) and separability (95% lower-bound Hedges' g = 1.08) between benign and malignant nodules along a direction in principal component space representing effective stiffness. Preliminary clustering patterns were also observed among malignant subtypes, including follicular, oncocytic, and papillary thyroid carcinomas. Together, these results highlight the potential of Digital Palpation as a novel mechanics-based method for tissue characterization and motivate its further development toward diagnostic applications.

physics.data-an↗

Numerical Integration Instabilities in Likelihood Fits: Mechanisms and Remedies

Numerical instabilities in the normalization of probability density functions can produce artificially lower negative log-likelihood (NLL) values than the true minimum of a likelihood fit, even when the resulting fit provides a poorer description of the data. Motivated by anomalously low NLL values found in non-converged fits associated with a recent CMS search for fully charmed tetraquark candidates, we use a pseudo-dataset generated from a likelihood model based on that analysis to investigate how numerical integration can yield unreliable normalization results, how these errors affect likelihood minimization, and how they can be addressed. We find that, even at fixed integration tolerance, the stopping decision of a numerical integrator can change with the fit parameters, introducing discontinuities in the normalization integrals that propagate to the likelihood surface. Such discontinuities can trap the minimizer at a numerical step and yield an artificially lower NLL. Tightening the integration tolerance mitigates these numerical discontinuities, while adaptive integration methods, such as Gauss--Kronrod quadrature, can also improve the numerical stability. A more severe failure occurs when the integration grid cannot adequately resolve a sharply localized contribution. In this case, the integrator may satisfy its estimated-error criterion despite substantially underestimating the normalization, allowing the minimizer to enter a region with an artificially low NLL. Tightening integration tolerances or using alternative adaptive integration methods does not necessarily resolve sharply localized contributions. We demonstrate that a suitable variable transformation can improve their numerical resolution, yielding more accurate normalization integrals and restoring fit convergence.

physics.data-an↗