Searcharxiv⌕ Search

arXiv · 2611.22232

MASQ: Measurement-Adaptive Sampling for Near-Clifford Quantum Error Correction Circuits

Abstract

Classical sampling of quantum error correction (QEC) circuits supports fault-tolerant protocol evaluation, but estimating rare logical failures requires many independent shots. Frame-active-state simulators isolate non-stabilizer information in a dense active-state vector, yet dense-state processing remains exponential in the active width. This paper presents MASQ, an exact measurement-adaptive sampler for near-Clifford QEC circuits based on selective materialization of non-Clifford rotations. At each measurement boundary, MASQ materializes only rotations in a measurement-relevant closure capturing direct and indirect non-commuting dependencies, deferring the rest to limit active-state expansion. Stabilizer-assisted elimination further removes rotations certified to be invisible to all future measurements. A circuit-dependent schedule is computed once and shared across shots, while adaptive caching of conditional Born probabilities and batched execution reduce repeated sampling work while preserving the measurement-record distribution. Across 19 QEC benchmarks, MASQ reduces peak active width by up to 40 active virtual qubits and achieves up to 8,098-fold CPU throughput speedup over Clifft on multi-round circuits.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Chaebin Jung, Sangmin Jeon, Kyeongwon Lee, Sechan Park, Woojoo Lee. 2026-11-17. MASQ: Measurement-Adaptive Sampling for Near-Clifford Quantum Error Correction Circuits. https://searcharxiv.com/abs/2611.22232

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Searcharxiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Automated-Truck Penetration Shapes Human Drivers' Car-Following Margins Near Motorway Ramps: A Driving-Simulator Study

Automated-vehicle dedicated lanes (AVDLs) are proposed as transitional infrastructure for mixed traffic, but their effect near ramps, and that of automated trucks, on the human drivers sharing the road has rarely been observed. In a mixed-design driving-simulator experiment, 63 drivers were assigned to one of four layouts (an AVDL extending beyond, coinciding with, or ending inside a 1.5-km ramp weaving section, or no AVDL) and drove at four automated-truck penetration levels from 20% to 80%. Linear mixed-effects models with participant random effects and multiplicity control were used. Higher penetration reduced the share of car-following time at gaps below 1.5 s from 28.5% to 18.1% (Holm-adjusted p = .006). This was explained by leader composition: drivers spent 8% of following time behind a truck at 20% penetration and 48% at 80%, kept longer gaps behind trucks, and did not change their gaps within leader type. AVDL layout had no detectable effect on safety margins, rear-end conflict rates, travel time or speed (differences bounded within plus or minus 5 s per section) and no significant effect on workload. Between-driver differences accounted for 52% to 77% of the variance in the main outcomes. Mixed-traffic models should therefore represent human car-following as leader-type-dependent and heterogeneous.

cs.ET↗

Countering Anion Inhibition of Laccase Electron Transfer: Electrostatic Design, Charge-Transfer Dynamics on a Superconducting Quantum Processor, and Its Limits

Hydroxide at neutral-to-alkaline pH and halides inhibit fungal laccases and limit their use in wastewater treatment. From GFN2-xTB cluster models of Trametes versicolor laccase (PDB 1GYC) we build a four-site Hubbard model of the His454-T3A-T3B-His452 junction of the trinuclear copper cluster and execute its charge-transfer dynamics on the Euro-Q-Exa quantum computer (IQM, 8 qubits, Trotterized circuits with Pauli twirling; 726 jobs). The charge-transfer frequency is measured to 3-5 meV, reproducibly over nine days and across changes of the device qubit map: hydroxide raises the charge-transfer energy of the crystal-geometry model by 92.0 +/- 2.2 meV (exact 87) and exceeds fluoride by 10.1 +/- 1.8 meV. A screen of charged probes in three dielectric models identifies Y116E; in the probe model the hardware resolves a reduction of the hydroxide penalty by 74 +/- 7 meV and of the halide penalty by 64 +/- 5 meV, acting on the site-energy gap rather than on the coupling. A real Glu116 (five conformers) with PROPKA protonation states and the coupled Asp456 gives a realistic reduction of 10-30 meV, with the same sign in 28 of 28 model combinations; the direction and ordering are the prediction, rate factors only an illustration. Scanning the on-site repulsion reverses the sign of the hydroxide effect, and a one-electron Hartree model reproduces the reversal: the measured dynamics is effectively single-particle. On a Fermi-Hubbard benchmark the hardware does not resolve electron correlation; it would need a contrast loss below 0.13 percent per CZ gate instead of the measured 0.34-0.54 percent.

cs.ET↗

A Copper-Inducible Yeast Biosensor with Bioluminescent Readout: Mathematical Modeling, Experimental Validation, and Photodetector Coupling for Molecular Communication in IoBNT

Engineered living biosensors constitute promising model organisms for bringing Molecular Communications (MC) closer to practical applications. However, challenges associated with their development and characterization have resulted in the relevant literature being limited in the MC domain, . In this paper, we contribute in this direction by leveraging engineered yeast as a basis to detect heavy metals such as copper. The biosensor's development is supported by a validated mathematical characterization and analysis for possible integration in an MC system. Different from the existing literature, mathematical representations of the major biological processes within the yeast copper detoxification pathway are integrated into a comprehensive framework that predicts the time evolution of the CUP1 gene, which is treated as the system output. In the engineered circuit, CUP1 was replaced with GFP, therefore making GFP fluorescence the final system output. Experimental analysis including mRNA transcript quantification and fluorometric measurements, validate the GFP reporting model to a satisfactory degree. This establishes the proposed model as a useful tool for virtual experimentation and the developed testbed as a suitable platform for further engineering of yeast-based copper sensors. The theoretical analysis is further extended by incorporating a self-sustained bioluminescent reporter for yeast, replacing GFP and enabling optical output without external light excitation. The optical response is coupled to a photodetector model, rendering the system suitable for integration into mobile monitoring devices such as Smart Pills. The presented characterization of the yeast receiver as a copper biosensor, constitutes the first step towards the development and characterization of a complete end-to-end MC based system for gut theranostics after coupling with suitable engineered probiotic senders.

cs.ET↗