arXiv · astro-ph/0206093
1/f noise and other systematic effects in the Planck-LFI radiometers
Abstract
We use an analytic approach to study the susceptibility of the Planck Low Frequency Instrument radiometers to various systematic effects. We examine the effects of fluctuations in amplifier gain, in amplifier noise temperature and in the reference load temperature. We also study the effect of imperfect gain modulation, non-ideal matching of radiometer parameters, imperfect isolation in the two legs of the radiometer and back-end 1/f noise. We find that with proper gain modulation 1/f gain fluctuations are suppressed, leaving fluctuations in amplifier noise temperature as the main source of 1/f noise. We estimate that with a gain modulation factor within +- 1% of its ideal value the overall 1/f knee frequency will be relatively small (< 0.1 Hz).
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Michael Seiffert, Aniello Mennella, Carlo Burigana, Nazzareno Mandolesi, Marco Bersanelli, Peter Meinhold, Phil Lubin. 2002-06-06. 1/f noise and other systematic effects in the Planck-LFI radiometers. https://doi.org/10.1051/0004-6361%3A20020880
Cite the original work for its findings. Save a collection to share your selection of sources.