SearcharxivSearch

arXiv · astro-ph/0207263

XMM-Newton observes flaring in the polar UZ For during a low state

Abstract

During an XMM-Newton observation, the eclipsing polar UZ For was found in a peculiar state with an extremely low X-ray luminosity and occasional X-ray and UV flaring. For most of the observation, UZ For was only barely detected in X-rays and about 800 times fainter than during a high state previously observed with ROSAT. A transient event, which lasted about 900 s, was detected simultaneously by the X-ray instruments and, in the UV, by the Optical Monitor. The transient was likely caused by the impact of 10^17-10^18 g of gas on the main accretion region of the white dwarf. The X-ray spectrum of the transient is consistent with 7 keV thermal bremsstrahlung from the shock-heated gas in the accretion column. A soft blackbody component due to reprocessing of X-rays in the white dwarf atmosphere is not seen. The likely origin of the UV emission during the transient is cyclotron radiation from the accretion column. We conclude from our analysis that the unusual flaring during the low state of UZ For was caused by intermittent increases of the mass transfer rate due to stellar activity on the secondary.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dirk Pandel, France A. Cordova. 2002-07-12. XMM-Newton observes flaring in the polar UZ For during a low state. https://doi.org/10.1046/j.1365-8711.2002.05846.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Cosmic Variance and Its Effect on the Luminosity Function Determination in Deep High z Surveys

We study cosmic variance in deep high redshift surveys and its influence on the determination of the luminosity function for high redshift galaxies. For several survey geometries relevant for HST and JWST instruments, we characterize the distribution of the galaxy number counts. This is obtained by means of analytic estimates via the two point correlation function in extended Press-Schechter theory as well as by using synthetic catalogs extracted from N-body cosmological simulations of structure formation. We adopt a simple luminosity - dark halo mass relation to investigate the environment effects on the fitting of the luminosity function. We show that in addition to variations of the normalization of the luminosity function, a steepening of its slope is also expected in underdense fields, similarly to what is observed within voids in the local universe. Therefore, to avoid introducing artificial biases, caution must be taken when attempting to correct for field underdensity, such as in the case of HST UDF i-dropout sample, which exhibits a deficit of bright counts with respect to the average counts in GOODS. A public version of the cosmic variance calculator based on the two point correlation function integration is made available on the web.

astro-ph

Receiver control for the Submillimeter Array

Efficient operation of a submillimeter interferometer requires remote (preferably automated) control of mechanically tuned local oscillators, phase-lock loops, mixers, optics, calibration vanes and cryostats. The present control system for these aspects of the Submillimeter Array (SMA) will be described. Distributed processing forms the underlying architecture and the software is split between hardware platforms in a leader/follower arrangement. In each antenna cabin, a serial network of up to ten independent 80C196 microcontroller boards attaches to the real-time PowerPC computer (running LynxOS). A multi-threaded, gcc-compiled leader program on the PowerPC accepts top-level requests via remote procedure calls (RPC), subsequently dispatches tuning commands to the relevant follower microcontrollers, and regularly reports the system status to optical-fiber-based reflective memory for common access by the telescope monitor and error reporting system. All serial communication occurs asynchronously via encoded, variable-length packets. The microcontrollers respond to the requested commands and queries by accessing non-volatile, rewriteable lookup-tables (when appropriate) and executing embedded software that operates additional electronic devices (DACs, ADCs, etc.). Since various receiver hardware components require linear or rotary motion, each microcontroller also implements a position servo via a one-millisecond interrupt service routine which drives a DC-motor/encoder combination that remains standard across each subsystem.

astro-ph

Classical analysis of the rotational dynamic of spiral galaxies: Quo Vadis Dark Matter?

In this paper we study a stellar dynamic model for the stars' rotational-dynamics, with a distribution of its own mass, rotating around its center with a higher density, like spiral galaxies happen, by means of a classical calculus of the rotation velocities of a particle around its rotational axis, inside a smoothed distribution of matter. The stars are supposed to be particles and their distribution in the galaxy is modelled as a matter distribution inversely proportional to its distance from its center. Two kinds of matter distribution are supposed: one with constant density, and other with radial distribution. Two types of galaxy symmetry are also considered: spherical and oblate ellipsoidal. Using only classical mechanics arguments it is shown that the calculated velocity distribution inside the galaxy is similar to that obtained from astronomical observations, without the necessity of suppose the existence of dark matter or other phenomena.

astro-ph