arXiv · cond-mat/0212387
Measuring velocity of sound with nuclear resonant inelastic x-ray scattering
Abstract
Nuclear resonant inelastic x-ray scattering is used to measure the projected partial phonon density of states of materials. A relationship is derived between the low-energy part of this frequency distribution function and the sound velocity of materials. Our derivation is valid for harmonic solids with Debye-like low-frequency dynamics. This method of sound velocity determination is applied to elemental, composite, and impurity samples which are representative of a wide variety of both crystalline and noncrystalline materials. Advantages and limitations of this method are elucidated.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Michael Y. Hu, Wolfgang Sturhahn, Thomas S. Toellner, Philip D. Mannheim, Dennis E. Brown, Jiyong Zhao, E. Ercan Alp. 2003-01-18. Measuring velocity of sound with nuclear resonant inelastic x-ray scattering. https://doi.org/10.1103/physrevb.67.094304