Physics Design Considerations of Diagnostic X Beam Transport System
Abstract
Diagnostic X (D-X) transport system would extract the beam from the downstream transport line of the second- axis of the Dual Axis Radiographic Hydrodynamic Test facility (DARHT-II) and transport this beam to the D-X firing point via four branches of the beamline in order to provide four lines of sight for x-ray radiography. The design goal is to generate four DARHT-II-like x-ray pulses on each line of sight. In this paper, we discuss several potential beam quality degradation processes in the passive magnet lattice beamline and indicate how they constrain the D-X beamline design parameters, such as the background pressure, the pipe size, and the pipe material