arXiv · physics/0105088
Sensitive Absolute Gravity Gradiometry Using Atom Interferometry
Abstract
We report the demonstration of a sensitive absolute gravity gradiometer based on light-pulse atom interference techniques. The gradiometer consists of two absolute accelerometers operated in a differential mode. We report a differential acceleration sensitivity of 4e-9 g/Hz^(1/2) and an inferred differential acceleration accuracy of less than 1e-9 g. This corresponds to a gravity gradient sensitivity of 4 E/Hz^(1/2) [1 E = 1e-9 s^(-2)] and an accuracy of better than 1 E for a 10 m separation between accelerometers. We demonstrate that the instrument can be used to detect nearby masses in a vibrationally noisy environment and characterize instrument sensitivity to spurious acceleration and rotation noise.
Explore related subjects
Keep this discovery
J. M. McGuirk, G. T. Foster, J. B. Fixler, M. J. Snadden, M. A. Kasevich. 2001-05-25. Sensitive Absolute Gravity Gradiometry Using Atom Interferometry. https://doi.org/10.1103/physreva.65.033608