Cylindrical Symmetry Discrimination of Magnetoelectric Optical Systematic Effects in a Pump-probe Atomic Parity Violation Experiment

Abstract

A pump-probe atomic parity violation (APV) experiment performed in a longitudinal electric field, provides a signal breaking mirror symmetry while preserving the cylindrical symmetry of the set-up. The excited vapor acts on the probe beam as a linear dichroic amplifier, imprinting a very specific signature on the detected signal. Our differential polarimeter is oriented to yield a null result unless the excited atoms are endowed with a chirality of some kind. Ideally, only the APV (E-odd) and the calibration (E-even) signals contribute to a chiral atomic response, a situation highly favourable to the detection of a tiny effect. In the present work we give a thorough analysis of possible unwanted defects like stray transverse fields or misalignments which would spoil the ideal set-up and lead to chiral systematics. A possible way to suppress such effects is to perform global rotations of the experiment by incremental steps of 45 degrees, leaving both stray fields and misalignments unaltered. The conspiration of at least two defects is necessary to affect the E-odd polarimeter signal. The transverse nature of the defects manifests itself by an azimuthal cosine square modulation. The harmful systematics are those which survive the averaging over four successive configurations. They require the presence of a stray transverse electric field, which can be determined and eventually minimized by auxiliary measurements of the systematic effects, amplified by applying a known external magnetic field. Transverse stray magnetic fields must be compensated by a similar procedure. We also propose statistical correlation tests as diagnoses of the aforementioned systematic effects.

Explore related subjects

Keep this discovery

BibTeXRIS

M-A. Bouchiat, J. Guéna, M. Lintz. 2003-11-20. Cylindrical Symmetry Discrimination of Magnetoelectric Optical Systematic Effects in a Pump-probe Atomic Parity Violation Experiment. https://doi.org/10.1140/epjd%2Fe2004-00021-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Delay-engineered dynamical phases in a programmable non-Markovian spin oscillator

Non-Markovian dynamics offer a new route towards engineering non-equilibrium matter, where memory and feedback act as programmable resources for controlling order in time. Here we report the realization of a non-Markovian spin oscillator in a hot vapour $^{129}$Xe-Cs co-magnetometer with programmable feedback delay and gain. By tuning these parameters, we observe a hierarchy of dynamical phases, including time-crystalline response, nonlinear bifurcations, and frequency-comb formation. The measured spectra and phase boundaries are captured by linear stability analysis of delayed Bloch equations, revealing these phenomena as different manifestations of the same memory-induced instability structure. These results establish time-delayed feedback as a powerful strategy for controlling non-equilibrium phases, enabling quantum sensing, frequency referencing, and synchronization within a single spin-based platform.

physics.atom-ph

Non-stick vacuum wall collisions with a laser-coolable molecule

Molecular species that are suitable for direct laser cooling are typically considered lost or destroyed if they collide with an ambient temperature vacuum wall. Here, we study surface collisions with aluminum monofluoride (AlF), a laser-coolable molecule that survives this process with unusually high probability. We detect the outgoing AlF molecules from a single wall collision via Doppler-sensitive laser-induced fluorescence spectroscopy, using incoming supersonic (pulsed) and thermochemical (continuous) molecular beams. The angular, velocity and rovibrational level distributions of the outgoing molecules show near-complete thermalisation to the wall in a single collision event. We determine an upper limit to the surface residence time of about 5$~\mu$s, and by monitoring the decay in density of pulses of molecules loaded into a small storage volume, we deduce the surface sticking probability for different materials. For a siloxane-coated metallic surface, the sticking probability of AlF is about 0.015, allowing us to accumulate molecules from the thermochemical source into an ambient temperature storage vessel at densities near $10^{8}~$cm$^{-3}$. This provides a route to compact, portable traps for neutral molecules.

physics.atom-ph

Kinetic modeling of molecular beam formation in a cryogenic buffer-gas cell

Cryogenic buffer-gas cells are widely used to produce cold molecular beams, but the microscopic dynamics governing beam formation remain challenging to model. Here we present fully kinetic simulations of a cryogenic buffer-gas cell using the Direct Simulation Monte Carlo method implemented in the PICLas framework, treating the buffer gas and ablated molecules within a single unified model. We capture characteristic features of cryogenic buffer-gas sources, including plume cooling, directed transport toward the aperture, and the formation of a slow molecular beam, while also resolving energy transfer from the hot ablation plume to the helium buffer gas that is inaccessible to existing approaches relying on the background-gas approximation. Our results demonstrate that fully kinetic simulations can provide detailed insights into buffer-gas cell dynamics and open a route toward a systematic optimization of such sources.

physics.atom-ph