Searcharxiv⌕ Search

arXiv · physics/9912034

Kalman Filter Track Fits and Track Breakpoint Analysis

Abstract

We give an overview of track fitting using the Kalman filter method in the NOMAD detector at CERN, and emphasize how the wealth of by-product information can be used to analyze track breakpoints (discontinuities in track parameters caused by scattering, decay, etc.). After reviewing how this information has been previously exploited by others, we describe extensions which add power to breakpoint detection and characterization. We show how complete fits to the entire track, with breakpoint parameters added, can be easily obtained from the information from unbroken fits. Tests inspired by the Fisher F-test can then be used to judge breakpoints. Signed quantities (such as change in momentum at the breakpoint) can supplement unsigned quantities such as the various chisquares. We illustrate the method with electrons from real data, and with Monte Carlo simulations of pion decays.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Pierre Astier, Alessandro Cardini, Robert D. Cousins, Antoine Letessier-Selvon, Boris A. Popov, Tatiana Vinogradova. 1999-12-16. Kalman Filter Track Fits and Track Breakpoint Analysis. https://doi.org/10.1016/s0168-9002(00)00154-6. https://searcharxiv.com/abs/physics/9912034

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Searcharxiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

A Paired Monte Carlo Intensity-Ratio Method for Incorporating Detector Resolution in Amplitude Analysis

Finite detector resolution can bias resonance parameters and fit fractions extracted from amplitude analyses. We present the paired Monte Carlo intensity-ratio method for incorporating resolution effects into amplitude analysis. The method uses ratios of reference intensities evaluated at paired truth-level and reconstructed kinematics to reweight the Monte Carlo normalization and approximately account for detector resolution. A resampling study of simulated $D^+\to K^+π^+π^-π^0$ decays shows that the method substantially reduces resolution-induced shifts in fitted resonance widths. Likelihood evaluation uses intensity calculations and normalization sums, avoiding a response convolution at each data event.

physics.data-an↗

Distinguishing thyroid nodule malignancy using digital palpation

Accurate pre-operative diagnosis of thyroid nodules remains a major clinical challenge. Current diagnostic techniques rely on fine-needle aspiration and demonstrate high rates of inconclusive results, often leading to avoidable thyroidectomies with lifelong implications. Here, we introduce a mechanics-based diagnostic method that leverages Digital Palpation to determine malignancy and identify tissue subtypes in human thyroid nodules. From a cohort of patients undergoing thyroidectomies, we evaluated ex vivo thyroid specimens and processed the resulting mechanical data from 36 tests in 10 thyroid nodules. Principal Component Analysis reveals that these experimental results are distributed within a three-dimensional space of interpretable scalar features reflecting tissue grittiness, strength, and toughness, which map closely to descriptions of malignant and benign nodules given by clinicians. Our results further demonstrate that malignant nodules exhibit distinct mechanical signatures compared to their benign counterparts. This revealed a statistically significant difference (p = 9 x 10^-4) and separability (95% lower-bound Hedges' g = 1.08) between benign and malignant nodules along a direction in principal component space representing effective stiffness. Preliminary clustering patterns were also observed among malignant subtypes, including follicular, oncocytic, and papillary thyroid carcinomas. Together, these results highlight the potential of Digital Palpation as a novel mechanics-based method for tissue characterization and motivate its further development toward diagnostic applications.

physics.data-an↗

Numerical Integration Instabilities in Likelihood Fits: Mechanisms and Remedies

Numerical instabilities in the normalization of probability density functions can produce artificially lower negative log-likelihood (NLL) values than the true minimum of a likelihood fit, even when the resulting fit provides a poorer description of the data. Motivated by anomalously low NLL values found in non-converged fits associated with a recent CMS search for fully charmed tetraquark candidates, we use a pseudo-dataset generated from a likelihood model based on that analysis to investigate how numerical integration can yield unreliable normalization results, how these errors affect likelihood minimization, and how they can be addressed. We find that, even at fixed integration tolerance, the stopping decision of a numerical integrator can change with the fit parameters, introducing discontinuities in the normalization integrals that propagate to the likelihood surface. Such discontinuities can trap the minimizer at a numerical step and yield an artificially lower NLL. Tightening the integration tolerance mitigates these numerical discontinuities, while adaptive integration methods, such as Gauss--Kronrod quadrature, can also improve the numerical stability. A more severe failure occurs when the integration grid cannot adequately resolve a sharply localized contribution. In this case, the integrator may satisfy its estimated-error criterion despite substantially underestimating the normalization, allowing the minimizer to enter a region with an artificially low NLL. Tightening integration tolerances or using alternative adaptive integration methods does not necessarily resolve sharply localized contributions. We demonstrate that a suitable variable transformation can improve their numerical resolution, yielding more accurate normalization integrals and restoring fit convergence.