Searcharxiv⌕ Search

arXiv subjects

Éamonn J. Harvey

Publications and source records attributed to Éamonn J. Harvey.

2 recordsLinked to original sources

ANDES, the high-resolution spectrograph for the ELT: design and performance analysis of the YJH spectrograph

The ArmazoNes high Dispersion Echelle Spectrograph (ANDES) is a powerful second-generation high-resolution spectroscopic instrument for the Extremely Large Telescope (ELT). The UBV, RIZ, and YJH modules comprise fibre-fed spectrographs of the ANDES baseline design and will offer continuous wavelength coverage of 0.35-1.8 $μ$m, with the addition of a K-band channel providing coverage up to 2.4 $μ$m. Coupled with a spectral resolution of $\sim$100,000, ANDES must deliver the required wavelength calibration stability of 1 m/s over 24 hours, with a goal of 0.02 m/s across 10 years. These requirements establish the framework for the infrared module of ANDES, the YJH Spectrograph, leading to what will likely be the largest cryogenic, ultra-stable, high-resolution spectrograph ever built, and will offer the unique ability to observe in both seeing- and diffraction-limited modes interchangeably. We present the current design and performance analysis of the ANDES YJH Spectrograph, outlining the engineering challenges encountered alongside the corresponding strategies adopted to navigate them. In particular, we detail the technology development of the primary dispersing element, an echelle grating mosaic that will span over a metre in length.

astro-ph.IM↗

HARMONI at ELT: line spread functions in a diffraction limited spectrometer

HARMONI is the first light, adaptive optics assisted, near-IR integral field spectrograph for the ELT. It covers a spectral range from 800~nm to 2450~nm with resolving powers from 3000 to 7000 and spatial sampling of 25~mas and 6~mas. It can operate in two adaptive optics modes - SCAO (including a high contrast capability) and MCAO. The project is resuming its final design phase after a rescope design phase in 2025. Diffraction of the pupil becomes significant in a spectrograph where the slit width is comparable to the diffraction limited PSF. When the spatial coherence due to the narrow slit is considered, the resulting line spread function can be narrower than the geometric width of the input slit, with a non-linear dependence on the size of the pupil aperture after the slit. We outline the impact of these diffraction and spatial filtering effects on the line spread function of HARMONI and identify parameters that should be considered when designing a diffraction limited spectrograph.

astro-ph.IM↗