SearcharxivSearch

arXiv subjects

A Taylor

Publications and source records attributed to A Taylor.

3 recordsLinked to original sources

Three-Dimensional Bubbly Flow Measurement Using Event-based Vision Sensor Cameras

A three-camera Event-Based Vision Sensor (EVS) system is employed to perform three-dimensional measurements of bubble motion, morphology, and bubble{\DH}bubble interactions. The multi-EVS configuration mitigates the absence of direct depth information inherent to binary event-based imaging while preserving key advantages, including high temporal resolution, low latency, and reduced data throughput. The experimental configuration consisted of an octagonal tank equipped with a controlled particle release mechanism and an air diffuser. Camera synchronization and pulsed LED illumination were achieved using a dedicated signal generator and driver circuitry, while calibration was performed using pulsed-illumination recordings of a target acquired at multiple depths. A comprehensive, inhouse computational framework was developed to process the event data for three-dimensional motion trajectory reconstruction. The validation of the developed tracking framework followed a rigorous multi-stage pipeline to ensure reconstruction fidelity. The framework was initially benchmarked against synthetic rendering cases of increasing kinematic complexity to evaluate 3D trajectory reconstruction accuracy under controlled conditions, achieving sub-millimeter global accuracy with root-mean-square error (RMSE) values ranging from 0.015 to 0.36 mm. Following numerical validation, physical baseline experiments were conducted using precisely manufactured particle releases through both a gated chamber and a single-particle claw opening mechanism. Subsequently, dynamic bubble plumes generated via multiple inlets across various compressed air flow rates were evaluated. The EVS framework successfully resolved dense bubble-bubble interactions, producing smooth, physically consistent three-dimensional trajectories across all tested conditions. Quantitative results showed strong agreement, yielding an overall velocity consistency exceeding 97% between conventional centroid tracking and independent velocity estimates derived from continuous-illumination event streaks. Overall, this methodology demonstrates a robust framework for high-speed volumetric tracking and bubble flow measurement. However, event oversaturation remains a key hardware limitation in ultra-dense regimes, as oversaturation in a single camera can cause system desynchronization.

physics.class-ph

State space modelling and data analysis exercises in LISA Pathfinder

LISA Pathfinder is a mission planned by the European Space Agency to test the key technologies that will allow the detection of gravitational waves in space. The instrument on-board, the LISA Technology package, will undergo an exhaustive campaign of calibrations and noise characterisation campaigns in order to fully describe the noise model. Data analysis plays an important role in the mission and for that reason the data analysis team has been developing a toolbox which contains all the functionalities required during operations. In this contribution we give an overview of recent activities, focusing on the improvements in the modelling of the instrument and in the data analysis campaigns performed both with real and simulated data.

gr-qc

From laboratory experiments to LISA Pathfinder: achieving LISA geodesic motion

This paper presents a quantitative assessment of the performance of the upcoming LISA Pathfinder geodesic explorer mission. The findings are based on the results of extensive ground testing and simulation campaigns using flight hardware and flight control and operations algorithms. The results show that, for the central experiment of measuring the stray differential acceleration between the LISA test masses, LISA Pathfinder will be able to verify the overall acceleration noise to within a factor two of the LISA requirement at 1 mHz and within a factor 6 at 0.1 mHz. We also discuss the key elements of the physical model of disturbances, coming from LISA Pathfinder and ground measurement, that will guarantee the LISA performance.

gr-qc