Searcharxiv⌕ Search

arXiv subjects

A. A. Aguilar-Arevalo

Publications and source records attributed to A. A. Aguilar-Arevalo.

At least 19 recordsLinked to original sources

Axion-Like Particle Search with a Hybrid Cherenkov-Scintillation Detector

This analysis presents the first proof-of-concept search for axion-like particles (ALPs) using a hybrid Cherenkov-scintillation detector at a beam-dump facility. The work is based on the Coherent CAPTAIN-Mills (CCM) experiment, a 10-ton liquid argon light collection detector located at Los Alamos National Laboratory. The CCM200 detector is instrumented with 200 photomultiplier tubes (PMTs), providing approximately 50% photocathode coverage. To enable optical discrimination, 80% of the PMTs are coated with a wavelength-shifting material while the remaining 20% are left uncoated. This configuration, combined with nanosecond-scale timing resolution, provides sensitivity to prompt Cherenkov radiation while maintaining efficient detection of liquid argon scintillation light [1, 2]. This analysis constructs four observables that exploit the Cherenkov emission and event topology expected from ALP-induced electromagnetic interactions. These observables are combined into a likelihood-ratio classifier that provides powerful rejection of steady-state backgrounds. No statistically significant excess above the expected background prediction is observed for $10^{-3}~\mathrm{MeV} < m_a < 10~\mathrm{MeV}$. Nevertheless, the improved background rejection enabled by hybrid Cherenkov-scintillation detection allows this analysis to surpass the sensitivity of the previous CCM120 search [3] despite less exposure and demonstrate the physics potential for hybrid Cherenkov-scintillation detectors.

hep-ex↗

First Event-by-Event Identification of Cherenkov Radiation from Sub-MeV Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon (LAr) detector by the Coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments 7 tons (fiducial volume) of LAr with 200 8-inch photomultiplier tubes (PMTs), 80% of which are coated in a wavelength shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as $-6 \leq t < 0$ ns relative to the event start time $t=0$, the uncoated PMTs are primarily sensitive to visible Cherenkov photons. Using gamma-rays from a $^{22}$Na source for production of sub-MeV electrons, we isolated prompt Cherenkov light with $>5σ$ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector, and represents a milestone in low-energy particle detector development.

physics.ins-det↗

Measurement of the Liquid Argon Scintillation Pulse Shape Using Differentiable Simulation in the Coherent CAPTAIN-Mills Experiment

The Coherent CAPTAIN-Mills (CCM) experiment is a liquid argon (LAr) light collection detector searching for MeV-scale neutrino and Beyond Standard Model physics signatures. Two hundred 8-inch photomultiplier tubes (PMTs) instrument the 7 ton fiducial volume with 50% photocathode coverage to detect light produced by charged particles. CCM's light-based approach reduces requirements of LAr purity, compared to other detection technologies, such that sub-MeV particles can be reliably detected without additional LAr filtration and with O(1) parts-per-million of common contaminants. We present a measurement of LAr light production and propagation parameters, with uncertainties, obtained from a sample of MeV-scale electromagnetic events. The optimization of this high-dimensional parameter space was facilitated by a differentiable optical photon Monte-Carlo simulation, and detailed PMT response characterization. This result accurately predicts the timing and spatial distribution of light due to scintillation and Cherenkov emission in the detector. This is the first description of photon propagation in LAr to include several effects, including: anomalous dispersion of the index of refraction near the ultraviolet resonance, Mie scattering from impurities, and Cherenkov light production.

physics.ins-det↗

Testing Meson Portal Dark Sector Solutions to the MiniBooNE Anomaly at CCM

A solution to the MiniBooNE excess invoking rare three-body decays of the charged pions and kaons to new states in the MeV mass scale was recently proposed as a dark-sector explanation. This class of solution illuminates the fact that, while the charged pions were focused in the target-mode run, their decay products were isotropically suppressed in the beam-dump-mode run in which no excess was observed. This suggests a new physics solution correlated to the mesonic sector. We investigate an extended set of phenomenological models that can explain the MiniBooNE excess as a dark sector solution, utilizing long-lived particles that might be produced in the three-body decays of the charged mesons and the two-body anomalous decays of the neutral mesons. Over a broad set of interactions with the long-lived particles, we show that these scenarios can be compatible with constraints from LSND, KARMEN, and MicroBooNE, and evaluate the sensitivity of the ongoing and future data taken by the Coherent CAPTAIN Mills experiment (CCM) to a potential discovery in this parameter space. See addendum for updated predictions for future MicroBooNE sensitivity.

hep-ph↗

Physics Opportunities at a Beam Dump Facility at PIP-II at Fermilab and Beyond

The Fermilab Proton-Improvement-Plan-II (PIP-II) is being implemented in order to support the precision neutrino oscillation measurements at the Deep Underground Neutrino Experiment, the U.S. flagship neutrino experiment. The PIP-II LINAC is presently under construction and is expected to provide 800~MeV protons with 2~mA current. This white paper summarizes the outcome of the first workshop on May 10 through 13, 2023, to exploit this capability for new physics opportunities in the kinematic regime that are unavailable to other facilities, in particular a potential beam dump facility implemented at the end of the LINAC. Various new physics opportunities have been discussed in a wide range of kinematic regime, from eV scale to keV and MeV. We also emphasize that the timely establishment of the beam dump facility at Fermilab is essential to exploit these new physics opportunities.

hep-ex↗

Prospects for detecting axionlike particles at the Coherent CAPTAIN-Mills experiment

We show results from the Coherent CAPTAIN Mills (CCM) 2019 engineering run which begin to constrain regions of parameter space for axion-like particles (ALPs) produced in electromagnetic particle showers in an 800 MeV proton beam dump, and further investigate the sensitivity of ongoing data-taking campaigns for the CCM200 upgraded detector. Based on beam-on background estimates from the engineering run, we make realistic extrapolations for background reduction based on expected shielding improvements, reduced beam width, and analysis-based techniques for background rejection. We obtain reach projections for two classes of signatures; ALPs coupled primarily to photons can be produced in the tungsten target via the Primakoff process, and then produce a gamma-ray signal in the Liquid Argon (LAr) CCM detector either via inverse Primakoff scattering or decay to a photon pair. ALPs with significant electron couplings have several additional production mechanisms (Compton scattering, $e^+e^-$ annihilation, ALP-bremsstrahlung) and detection modes (inverse Compton scattering, external $e^+e^-$ pair conversion, and decay to $e^+e^-$). In some regions, the constraint is marginally better than both astrophysical and terrestrial constraints. With the beginning of a three year run, CCM will be more sensitive to this parameter space by up to an order of magnitude for both ALP-photon and ALP-electron couplings. The CCM experiment will also have sensitivity to well-motivated parameter space of QCD axion models. It is only a recent realization that accelerator-based large volume liquid argon detectors designed for low energy coherent neutrino and dark matter scattering searches are also ideal for probing ALPs in the unexplored $\sim$MeV mass scale.

hep-ph↗

MiniBooNE and MicroBooNE Combined Fit to a 3+1 Sterile Neutrino Scenario

This letter presents the results from the MiniBooNE experiment within a full "3+1" scenario where one sterile neutrino is introduced to the three-active-neutrino picture. In addition to electron-neutrino appearance at short-baselines, this scenario also allows for disappearance of the muon-neutrino and electron-neutrino fluxes in the Booster Neutrino Beam, which is shared by the MicroBooNE experiment. We present the 3+1 fit to the MiniBooNE electron-(anti)neutrino and muon-(anti)neutrino data alone, and in combination with MicroBooNE electron-neutrino data. The best-fit parameters of the combined fit with the exclusive CCQE analysis (inclusive analysis) are $Δm^2 = 0.29 eV^2 (0.33 eV^2)$, $|U_{e4}|^2 = 0.016 (0.500)$, $|U_{μ4}|^2 = 0.500 (0.500)$, and $\sin^2(2θ_{μe})=0.0316 (1.0)$. Comparing the no-oscillation scenario to the 3+1 model, the data prefer the 3+1 model with a $Δχ^2/\text{dof} = 24.7 / 3 (17.3 / 3)$, a $4.3σ(3.4σ)$ preference assuming the asymptotic approximation given by Wilks' theorem.

hep-ex↗

First Dark Matter Search Results From Coherent CAPTAIN-Mills

This paper describes the operation of the Coherent CAPTAIN-Mills (CCM) detector located at the Lujan Neutron Science Center (LANSCE) at Los Alamos National Laboratory (LANL). CCM is a 10-ton liquid argon (LAr) detector located 20 meters from a high flux neutron/neutrino source and is designed to search for sterile neutrinos ($ν_s$) and light dark matter (LDM). An engineering run was performed in Fall 2019 to study the characteristics of the CCM120 detector by searching for coherent scattering signals consistent with $ν_s$'s and LDM resulting from $π^+$ and $π^0$ decays in the tungsten target. New parameter space in a leptophobic dark matter model was excluded for DM masses between $\sim2.0$ and 30 MeV. The lessons learned from this run have guided the development and construction of the new CCM200 detector that will begin operations in 2021 and significantly improve on these searches.

hep-ex↗

First Leptophobic Dark Matter Search from Coherent CAPTAIN-Mills

We report the first results of a search for leptophobic dark matter (DM) from the Coherent CAPTAIN-Mills (CCM) liquid argon (LAr) detector. An engineering run with 120 photomultiplier tubes (PMTs) and $17.9 \times 10^{20}$ protons-on-target (POT) was performed in Fall 2019 to study the characteristics of the CCM detector. The operation of this 10-ton detector was strictly light-based with a threshold of 50 keV and used coherent elastic scattering off argon nuclei to detect DM. Despite only 1.5 months of accumulated luminosity, contaminated LAr, and non-optimized shielding, CCM's first engineering run already achieved sensitivity to previously unexplored parameter space of light dark matter (LDM) models with a baryonic vector portal. With an expected background of 115,005 events, we observe 115,005+16.5 events which is compatible with background expectations. For a benchmark mediator-to-dark matter mass ratio of $m_{_{V_B}}/m_χ=2.1$, DM masses within the range $9\,\text{MeV} \lesssim m_χ\lesssim 50\,\text{MeV}$ have been excluded at 90% C.L. in the leptophobic model after applying the Feldman-Cousins test statistic. CCM's upgraded run with 200 PMTs, filtered LAr, improved shielding, and ten times more POT will be able to exclude the remaining thermal relic density parameter space of this model, as well as probe new parameter space of other leptophobic DM models.

hep-ex↗

MiniBooNE Data Releases

The MiniBooNE experiment has provided data releases for most publications. Occasionally it is necessary to move data release pages. This document provides a single point of reference that will be updated by the collaboration to point to the present location of the MiniBooNE data releases.

hep-ex↗

Updated MiniBooNE Neutrino Oscillation Results with Increased Data and New Background Studies

The MiniBooNE experiment at Fermilab reports a total excess of $638.0 \pm 132.8$ electron-like events ($4.8 σ$) from a data sample corresponding to $18.75 \times 10^{20}$ protons-on-target in neutrino mode, which is a 46\% increase in the data sample with respect to previously published results, and $11.27 \times 10^{20}$ protons-on-target in antineutrino mode. The additional statistics allow several studies to address questions on the source of the excess. First, we provide two-dimensional plots in visible energy and cosine of the angle of the outgoing lepton, which can provide valuable input to models for the event excess. Second, we test whether the excess may arise from photons that enter the detector from external events or photons exiting the detector from $π^0$ decays in two model independent ways. Beam timing information shows that almost all of the excess is in time with neutrinos that interact in the detector. The radius distribution shows that the excess is distributed throughout the volume, while tighter cuts on the fiducal volume increase the significance of the excess. We conclude that models of the event excess based on entering and exiting photons are disfavored.

hep-ex↗

Search for pair and single production of vectorlike quarks in final states with at least one $Z$ boson decaying into a pair of electrons or muons in $pp$ collision data collected with the ATLAS detector at $\sqrt{s} = 13$ TeV

A search for vectorlike quarks is presented, which targets their decay into a $Z$ boson and a third-generation Standard Model quark. In the case of a vectorlike quark $T$ ($B$) with charge $+2/3e$ ($-1/3e$), the decay searched for is $T \rightarrow Zt$ ($B \rightarrow Zb$). Data for this analysis were taken during 2015 and 2016 with the ATLAS detector at the Large Hadron Collider and correspond to an integrated luminosity of 36.1 fb$^{-1}$ of $pp$ collisions at $\sqrt{s} = 13$ TeV. The final state used is characterized by the presence of $b$-tagged jets, as well as a $Z$ boson with high transverse momentum, which is reconstructed from a pair of opposite-sign same-flavor leptons. Pair and single production of vectorlike quarks are both taken into account and are each searched for using optimized dileptonic exclusive and trileptonic inclusive event selections. In these selections, the high scalar sum of jet transverse momenta, the presence of high-transverse-momentum large-radius jets, as well as - in the case of the single-production selections - the presence of forward jets are used. No significant excess over the background-only hypothesis is found and exclusion limits at 95% confidence level allow masses of vectorlike quarks of $m_T > 1030$ GeV ($m_T > 1210$ GeV) and $m_B > 1010$ GeV ($m_B > 1140$ GeV) in the singlet (doublet) model. In the case of 100% branching ratio for $T\rightarrow Zt$ ($B\rightarrow Zb$), the limits are $m_T > 1340$ GeV ($m_B > 1220$ GeV). Limits at 95% confidence level are also set on the coupling to Standard Model quarks for given vectorlike quark masses.

hep-ex↗

Significant Excess of ElectronLike Events in the MiniBooNE Short-Baseline Neutrino Experiment

The MiniBooNE experiment at Fermilab reports results from an analysis of $ν_e$ appearance data from $12.84 \times 10^{20}$ protons on target in neutrino mode, an increase of approximately a factor of two over previously reported results. A $ν_e$ charged-current quasielastic event excess of $381.2 \pm 85.2$ events ($4.5 σ$) is observed in the energy range $200<E_ν^{QE}<1250$~MeV. Combining these data with the $\bar ν_e$ appearance data from $11.27 \times 10^{20}$ protons on target in antineutrino mode, a total $ν_e$ plus $\bar ν_e$ charged-current quasielastic event excess of $460.5 \pm 99.0$ events ($4.7 σ$) is observed. If interpreted in a two-neutrino oscillation model, $ν_μ \rightarrow ν_e$, the best oscillation fit to the excess has a probability of $21.1\%$, while the background-only fit has a $χ^2$ probability of $6 \times 10^{-7}$ relative to the best fit. The MiniBooNE data are consistent in energy and magnitude with the excess of events reported by the Liquid Scintillator Neutrino Detector (LSND), and the significance of the combined LSND and MiniBooNE excesses is $6.0 σ$. A two-neutrino oscillation interpretation of the data would require at least four neutrino types and indicate physics beyond the three neutrino paradigm.Although the data are fit with a two-neutrino oscillation model, other models may provide better fits to the data.

hep-ex↗

First Measurement of Monoenergetic Muon Neutrino Charged Current Interactions

We report the first measurement of monoenergetic muon neutrino charged current interactions. MiniBooNE has isolated 236 MeV muon neutrino events originating from charged kaon decay at rest ($K^+ \rightarrow μ^+ ν_μ$) at the NuMI beamline absorber. These signal $ν_μ$-carbon events are distinguished from primarily pion decay in flight $ν_μ$ and $\overlineν_μ$ backgrounds produced at the target station and decay pipe using their arrival time and reconstructed muon energy. The significance of the signal observation is at the 3.9$σ$ level. The muon kinetic energy, neutrino-nucleus energy transfer ($ω=E_ν-E_μ$), and total cross section for these events is extracted. This result is the first known-energy, weak-interaction-only probe of the nucleus to yield a measurement of $ω$ using neutrinos, a quantity thus far only accessible through electron scattering.

hep-ex↗

Dark Matter Search in a Proton Beam Dump with MiniBooNE

The MiniBooNE-DM collaboration searched for vector-boson mediated production of dark matter using the Fermilab 8 GeV Booster proton beam in a dedicated run with $1.86 \times 10^{20}$ protons delivered to a steel beam dump. The MiniBooNE detector, 490~m downstream, is sensitive to dark matter via elastic scattering with nucleons in the detector mineral oil. Analysis methods developed for previous MiniBooNE scattering results were employed, and several constraining data sets were simultaneously analyzed to minimize systematic errors from neutrino flux and interaction rates. No excess of events over background was observed, leading to a 90\% confidence limit on the dark-matter cross section parameter, $Y=ε^2α_D(m_χ/m_V)^4 \lesssim10^{-8}$, for $α_D=0.5$ and for dark-matter masses of $0.01<m_χ<0.3~\mathrm{GeV}$ in a vector portal model of dark matter. This is the best limit from a dedicated proton beam dump search in this mass and coupling range and extends below the mass range of direct dark matter searches. These results demonstrate a novel and powerful approach to dark matter searches with beam dump experiments.

hep-ex↗

Detector for measuring the $π^+\to e^+ν_e$ branching fraction

The PIENU experiment at TRIUMF is aimed at a measurement of the branching ratio $R^{e/μ}$ = ${Γ\big((π^{+} \rightarrow e^{+} ν_{e}) + (π^{+} \rightarrow e^{+} ν_{e}γ)\big)}/{Γ\big((π^{+} \rightarrow μ^{+} ν_μ)+(π^{+} \rightarrow μ^{+} ν_μγ)\big)}$ with precision $<$0.1\%. Incident pions, delivered at the rate of 60 kHz with momentum 75 MeV/c, were degraded and stopped in a plastic scintillator target. Pions and their decay product positrons were detected with plastic scintillators and tracked with multiwire proportional chambers and silicon strip detectors. The energies of the positrons were measured in a spectrometer consisting of a large NaI(T$\ell$) crystal surrounded by an array of pure CsI crystals. This paper provides a description of the PIENU experimental apparatus and its performance in pursuit of $R^{e/μ}$.

physics.ins-det↗

Using L/E Oscillation Probability Distributions

This paper explores the use of $L/E$ oscillation probability distributions to compare experimental measurements and to evaluate oscillation models. In this case, $L$ is the distance of neutrino travel and $E$ is a measure of the interacting neutrino's energy. While comparisons using allowed and excluded regions for oscillation model parameters are likely the only rigorous method for these comparisons, the $L/E$ distributions are shown to give qualitative information on the agreement of an experiment's data with a simple two-neutrino oscillation model. In more detail, this paper also outlines how the $L/E$ distributions can be best calculated and used for model comparisons. Specifically, the paper presents the $L/E$ data points for the final MiniBooNE data samples and, in the Appendix, explains and corrects the mistaken analysis published by the ICARUS collaboration.

hep-ex↗

A new investigation of electron neutrino appearance oscillations with improved sensitivity in the MiniBooNE+ experiment

We propose the addition of scintillator to the existing MiniBooNE detector to allow a test of the neutral-current/charged-current (NC/CC) nature of the MiniBooNE low-energy excess. Scintillator will enable the reconstruction of 2.2 MeV $γ$s from neutron-capture on protons following neutrino interactions. Low-energy CC interactions where the oscillation excess is observed should have associated neutrons with less than a 10% probability. This is in contrast to the NC backgrounds that should have associated neutrons in approximately 50% of events. We will measure these neutron fractions with $ν_μ$ CC and NC events to eliminate that systematic uncertainty. This neutron-fraction measurement requires $6.5\times10^{20}$ protons on target delivered to MiniBooNE with scintillator added in order to increase the significance of an oscillation excess to over $5σ$. This new phase of MiniBooNE will also enable additional important studies such as the spin structure of nucleon ($Δs$) via NC elastic scattering, a low-energy measurement of the neutrino flux via $\numu ^{12}C \rightarrow μ^{-} ^{12}N_\textrm{g.s.}$ scattering, and a test of the quasielastic assumption in neutrino energy reconstruction. These topics will yield important, highly-cited results over the next 5 years for a modest cost, and will help to train Ph.D. students and postdocs. This enterprise offers complementary information to that from the upcoming liquid Argon based MicroBooNE experiment. In addition, MicroBooNE is scheduled to receive neutrinos in early 2014, and there is minimal additional cost to also deliver beam to MiniBooNE.

hep-ex↗