Searcharxiv⌕ Search

arXiv subjects

A. Aguilar-Arevalo

Publications and source records attributed to A. Aguilar-Arevalo.

30 records · Page 2Linked to original sources

Search for low-mass WIMPs in a 0.6 kg day exposure of the DAMIC experiment at SNOLAB

We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices down to a signal of 60 eV electron equivalent. The data are consistent with radiogenic backgrounds, and constraints on the spin-independent WIMP-nucleon elastic-scattering cross section are accordingly placed. A region of parameter space relevant to the potential signal from the CDMS-II Si experiment is excluded using the same target for the first time. This result obtained with a limited exposure demonstrates the potential to explore the low-mass WIMP region (<10 GeV/$c^{2}$) of the upcoming DAMIC100, a 100 g detector currently being installed in SNOLAB.

astro-ph.CO↗

The CONNIE experiment

The CONNIE experiment uses fully depleted, high resistivity CCDs as particle detectors in an attempt to measure for the first time the Coherent Neutrino-Nucleus Elastic Scattering of antineutrinos from a nuclear reactor with silicon nuclei.This talk, given at the XV Mexican Workshop on Particles and Fields (MWPF), discussed the potential of CONNIE to perform this measurement, the installation progress at the Angra dos Reis nuclear power plant, as well as the plans for future upgrades.

physics.ins-det↗

Results of the engineering run of the Coherent Neutrino Nucleus Interaction Experiment (CONNIE)

The CONNIE detector prototype is operating at a distance of 30 m from the core of a 3.8 GW$_{\rm th}$ nuclear reactor with the goal of establishing Charge-Coupled Devices (CCD) as a new technology for the detection of coherent elastic neutrino-nucleus scattering. We report on the results of the engineering run with an active mass of 4 g of silicon. The CCD array is described, and the performance observed during the first year is discussed. A compact passive shield was deployed for the detector, producing an order of magnitude reduction in the background rate. The remaining background observed during the run was stable, and dominated by internal contamination in the detector packaging materials. The {\it in-situ} calibration of the detector using X-ray lines from fluorescence demonstrates good stability of the readout system. The event rates with the reactor on and off are compared, and no excess is observed coming from nuclear fission at the power plant. The upper limit for the neutrino event rate is set two orders of magnitude above the expectations for the standard model. The results demonstrate the cryogenic CCD-based detector can be remotely operated at the reactor site with stable noise below 2 e$^-$ RMS and stable background rates. The success of the engineering test provides a clear path for the upgraded 100 g detector to be deployed during 2016.

physics.ins-det↗

Status of the DAMIC direct dark matter search experiment

The DAMIC experiment uses fully depleted, high resistivity CCDs to search for dark matter particles. With an energy threshold $\sim$50 eV$_{ee}$, and excellent energy and spatial resolutions, the DAMIC CCDs are well-suited to identify and suppress radioactive backgrounds, having an unrivaled sensitivity to WIMPs with masses $<$6 GeV/$c^2$. Early results motivated the construction of a 100 g detector, DAMIC100, currently being installed at SNOLAB. This contribution discusses the installation progress, new calibration efforts near the threshold, a preliminary result with 2014 data, and the prospects for physics results after one year of data taking.

physics.ins-det↗

The DAMIC dark matter experiment

The DAMIC (Dark Matter in CCDs) experiment uses high resistivity, scientific grade CCDs to search for dark matter. The CCD's low electronic noise allows an unprecedently low energy threshold of a few tens of eV that make it possible to detect silicon recoils resulting from interactions of low mass WIMPs. In addition the CCD's high spatial resolution and the excellent energy response results in very effective background identification techniques. The experiment has a unique sensitivity to dark matter particles with masses below 10 GeV/c$^2$. Previous results have demonstrated the potential of this technology, motivating the construction of DAMIC100, a 100 grams silicon target detector currently being installed at SNOLAB. In this contribution, the mode of operation and unique imaging capabilities of the CCDs, and how they may be exploited to characterize and suppress backgrounds will be discussed, as well as physics results after one year of data taking.

physics.ins-det↗

Status of the TRIUMF PIENU Experiment

The PIENU experiment at TRIUMF aims to measure the pion decay branching ratio $R=Γ(π^+{\rightarrow}e^+ν_e(γ))/Γ(π^+{\rightarrow}μ^+ν_μ(γ))$ with precision $<0.1$% to provide a sensitive test of electron-muon universality in weak interactions. The current status of the PIENU experiment is presented.

physics.ins-det↗

Improved measurement of the $π\rightarrow \mbox{e} ν$ branching ratio

A new measurement of the branching ratio, $R_{e/μ} =Γ(π^+ \rightarrow \mbox{e}^+ ν+ π^+ \rightarrow \mbox{e}^+ νγ)/ Γ(π^+ \rightarrow μ^+ ν+ π^+ \rightarrow μ^+ νγ)$, resulted in $R_{e/μ}^{exp} = (1.2344 \pm 0.0023 (stat) \pm 0.0019 (syst)) \times 10^{-4}$. This is in agreement with the standard model prediction and improves the test of electron-muon universality to the level of 0.1 %.

hep-ex↗

Measurement of radioactive contamination in the high-resistivity silicon CCDs of the DAMIC experiment

We present measurements of radioactive contamination in the high-resistivity silicon charge-coupled devices (CCDs) used by the DAMIC experiment to search for dark matter particles. Novel analysis methods, which exploit the unique spatial resolution of CCDs, were developed to identify $α$ and $β$ particles. Uranium and thorium contamination in the CCD bulk was measured through $α$ spectroscopy, with an upper limit on the $^{238}$U ($^{232}$Th) decay rate of 5 (15) kg$^{-1}$ d$^{-1}$ at 95% CL. We also searched for pairs of spatially correlated electron tracks separated in time by up to tens of days, as expected from $^{32}$Si-$^{32}$P or $^{210}$Pb-$^{210}$Bi sequences of $β$ decays. The decay rate of $^{32}$Si was found to be $80^{+110}_{-65}$ kg$^{-1}$ d$^{-1}$ (95% CI). An upper limit of $\sim$35 kg$^{-1}$ d$^{-1}$ (95% CL) on the $^{210}$Pb decay rate was obtained independently by $α$ spectroscopy and the $β$ decay sequence search. These levels of radioactive contamination are sufficiently low for the successful operation of CCDs in the forthcoming 100 g DAMIC detector.

astro-ph.IM↗

Study of a Large NaI(Tl) Crystal

Using a narrow band positron beam, the response of a large high-resolution NaI(Tl) crystal to an incident positron beam was measured. It was found that nuclear interactions cause the appearance of additional peaks in the low energy tail of the deposited energy spectrum.

physics.ins-det↗

High Purity Pion Beam at TRIUMF

An extension of the TRIUMF M13 low-energy pion channel designed to suppress positrons based on an energy-loss technique is described. A source of beam channel momentum calibration from the decay pi+ --> e+ nu is also described.

physics.acc-ph↗

Leptonic CP violation studies at MiniBooNE in the (3+2) sterile neutrino oscillation hypothesis

We investigate the extent to which leptonic CP-violation in (3+2) sterile neutrino models leads to different oscillation probabilities for $\barν_μ\to\barν_e$ and $ν_μ\toν_e$ oscillations at MiniBooNE. We are using a combined analysis of short-baseline (SBL) oscillation results, including the LSND and null SBL results, to which we impose additional constraints from atmospheric oscillation data. We obtain the favored regions in MiniBooNE oscillation probability space for both (3+2) CP-conserving and (3+2) CP-violating models. We further investigate the allowed CP-violation phase values and the MiniBooNE reach for such a CP violation measurement. The analysis shows that the oscillation probabilities in MiniBooNE neutrino and antineutrino running modes can differ significantly, with the latter possibly being as much as three times larger than the first. In addition, we also show that all possible values of the single CP-violation phase measurable at short baselines in (3+2) models are allowed within 99% CL by existing data.

hep-ph↗

Active neutrino Oscillations and the SNO neutral Current measurement

We discuss the relation between the observed CC, ES, and NC fluxes with the flavor fractional content of the solar neutrino flux seen by SNO. By using existing estimates of the cross sections for the charged and neutral current reactions which take into account the detector resolution, we show how the forthcoming SNO rates unconstrained by the standard $^8$B shape could test the oscillations into active states. We perform a model independent analysis for the Super-K and SNO data, assuming a non distorted spectrum.

hep-ph↗