Searcharxiv⌕ Search

arXiv subjects

A. Amorim

Publications and source records attributed to A. Amorim.

At least 91 records · Page 5Linked to original sources

GRAVITY: the VLTI 4-beam combiner for narrow-angle astrometry and interferometric imaging

GRAVITY is the second generation Very Large Telescope Interferometer instrument for precision narrow-angle astrometry and interferometric imaging in the Near Infra-Red (NIR). It shall provide precision astrometry of order 10 microarcseconds, and imaging capability at a few milliarcsecond resolution, and hence will revolutionise dynamical measurements of celestial objects. GRAVITY is currently in the last stages of its integration and tests in Garching at MPE, and will be delivered to the VLT Interferometer (VLTI) in 2015. We present here the instrument, with a particular focus on the components making use of fibres: integrated optics beam combiners, polarisation rotators, fibre differential delay lines, and the metrology.

astro-ph.IM↗

The GRAVITY metrology system: narrow-angle astrometry via phase-shifting interferometry

The VLTI instrument GRAVITY will provide very powerful astrometry by combining the light from four telescopes for two objects simultaneously. It will measure the angular separation between the two astronomical objects to a precision of 10 microarcseconds. This corresponds to a differential optical path difference (dOPD) between the targets of few nanometers and the paths within the interferometer have to be maintained stable to that level. For this purpose, the novel metrology system of GRAVITY will monitor the internal dOPDs by means of phase-shifting interferometry. We present the four-step phase-shifting concept of the metrology with emphasis on the method used for calibrating the phase shifts. The latter is based on a phase-step insensitive algorithm which unambiguously extracts phases in contrast to other methods that are strongly limited by non-linearities of the phase-shifting device. The main constraint of this algorithm is to introduce a robust ellipse fitting routine. Via this approach we are able to measure phase shifts in the laboratory with a typical accuracy of lambda/2000 or 1 nanometer of the metrology wavelength.

astro-ph.IM↗

The fiber coupler and beam stabilization system of the GRAVITY interferometer

We present the installed and fully operational beam stabilization and fiber injection subsystem feeding the 2nd generation VLTI instrument GRAVITY. The interferometer GRAVITY requires an unprecedented stability of the VLTI optical train to achieve micro-arcsecond astrometry. For this purpose, GRAVITY contains four fiber coupler units, one per telescope. Each unit is equipped with actuators to stabilize the telescope beam in terms of tilt and lateral pupil displacement, to rotate the field, to adjust the polarization and to compensate atmospheric piston. A special roof-prism offers the possibility of on-axis as well as off-axis fringe tracking without changing the optical train. We describe the assembly, integration and alignment and the resulting optical quality and performance of the individual units. Finally, we present the closed-loop performance of the tip-tilt and pupil tracking achieved with the final systems in the lab.

astro-ph.IM↗

GRAVITY: the Calibration Unit

We present in this paper the design and characterisation of a new sub-system of the VLTI 2nd generation instrument GRAVITY: the Calibration Unit. The Calibration Unit provides all functions to test and calibrate the beam combiner instrument: it creates two artificial stars on four beams, and dispose of four delay lines with an internal metrology. It also includes artificial stars for the tip-tilt and pupil guiding systems, as well as four metrology pick-up diodes, for tests and calibration of the corresponding sub-systems. The calibration unit also hosts the reference targets to align GRAVITY to the VLTI, and the safety shutters to avoid the metrology light to propagate in the VLTI-lab. We present the results of the characterisation and validtion of these differrent sub-units.

astro-ph.IM↗

The GRAVITY metrology system: modeling a metrology in optical fibers

GRAVITY is the second generation VLT Interferometer (VLTI) instrument for high-precision narrow-angle astrometry and phase-referenced interferometric imaging. The laser metrology system of GRAVITY is at the heart of its astrometric mode, which must measure the distance of 2 stars with a precision of 10 micro-arcseconds. This means the metrology has to measure the optical path difference between the two beam combiners of GRAVITY to a level of 5 nm. The metrology design presents some non-common paths that have consequently to be stable at a level of 1 nm. Otherwise they would impact the performance of GRAVITY. The various tests we made in the past on the prototype give us hints on the components responsible for this error, and on their respective contribution to the total error. It is however difficult to assess their exact origin from only OPD measurements, and therefore, to propose a solution to this problem. In this paper, we present the results of a semi-empirical modeling of the fibered metrology system, relying on theoretical basis, as well as on characterisations of key components. The modeling of the metrology system regarding various effects, e.g., temperature, waveguide heating or mechanical stress, will help us to understand how the metrology behave. The goals of this modeling are to 1) model the test set-ups and reproduce the measurements (as a validation of the modeling), 2) determine the origin of the non-common path errors, and 3) propose modifications to the current metrology design to reach the required 1nm stability.

astro-ph.IM↗

The interferometric baselines and GRAVITY astrometric error budget

GRAVITY is a new generation beam combination instrument for the VLTI. Its goal is to achieve microarsecond astrometric accuracy between objects separated by a few arcsec. This $10^6$ accuracy on astrometric measurements is the most important challenge of the instrument, and careful error budget have been paramount during the technical design of the instrument. In this poster, we will focus on baselines induced errors, which is part of a larger error budget.

astro-ph.IM↗

J-PAS: The Javalambre-Physics of the Accelerated Universe Astrophysical Survey

The Javalambre-Physics of the Accelerated Universe Astrophysical Survey (J-PAS) is a narrow band, very wide field Cosmological Survey to be carried out from the Javalambre Observatory in Spain with a purpose-built, dedicated 2.5m telescope and a 4.7 sq.deg. camera with 1.2Gpix. Starting in late 2015, J-PAS will observe 8500sq.deg. of Northern Sky and measure $0.003(1+z)$ photo-z for $9\times10^7$ LRG and ELG galaxies plus several million QSOs, sampling an effective volume of $\sim 14$ Gpc$^3$ up to $z=1.3$ and becoming the first radial BAO experiment to reach Stage IV. J-PAS will detect $7\times 10^5$ galaxy clusters and groups, setting constrains on Dark Energy which rival those obtained from its BAO measurements. Thanks to the superb characteristics of the site (seeing ~0.7 arcsec), J-PAS is expected to obtain a deep, sub-arcsec image of the Northern sky, which combined with its unique photo-z precision will produce one of the most powerful cosmological lensing surveys before the arrival of Euclid. J-PAS unprecedented spectral time domain information will enable a self-contained SN survey that, without the need for external spectroscopic follow-up, will detect, classify and measure $σ_z\sim 0.5\%$ redshifts for $\sim 4000$ SNeIa and $\sim 900$ core-collapse SNe. The key to the J-PAS potential is its innovative approach: a contiguous system of 54 filters with $145Å$ width, placed $100Å$ apart over a multi-degree FoV is a powerful "redshift machine", with the survey speed of a 4000 multiplexing low resolution spectrograph, but many times cheaper and much faster to build. The J-PAS camera is equivalent to a 4.7 sq.deg. "IFU" and it will produce a time-resolved, 3D image of the Northern Sky with a very wide range of Astrophysical applications in Galaxy Evolution, the nearby Universe and the study of resolved stellar populations.

astro-ph.CO↗

GRAVITY: beam stabilization and light injection subsystems

We present design results of the 2nd generation VLTI instrument GRAVITY beam stabilization and light injection subsystems. Designed to deliver micro-arcsecond astrometry, GRAVITY requires an unprecedented stability of the VLTI optical train. To meet the astrometric requirements, we have developed a dedicated 'laser guiding system', correcting the longitudinal and lateral pupil position as well as the image jitter. The actuators for the correction are provided by four 'fiber coupler' units located in the GRAVITY cryostat. Each fiber coupler picks the light of one telescope and stabilizes the beam. Furthermore each unit provides field de-rotation, polarization analysis as well as atmospheric piston correction. Using a novel roof prism design offers the possibility of on-axis as well as off-axis fringe tracking without changing the optical path. Finally the stabilized beam is injected with minimized losses into single-mode fibers via parabolic mirrors. We present lab results of the first guiding- as well as the first fiber coupler prototype regarding the closed loop performance and the optical quality. Based on the lab results we discuss the on-sky performance of the system and the implications concerning the sensitivity of GRAVITY.

astro-ph.IM↗

G0.253+0.016: a molecular cloud progenitor of an Arches-like cluster

Young massive clusters (YMCs) with stellar masses of 10^4 - 10^5 Msun and core stellar densities of 10^4 - 10^5 stars per cubic pc are thought to be the `missing link' between open clusters and extreme extragalactic super star clusters and globular clusters. As such, studying the initial conditions of YMCs offers an opportunity to test cluster formation models across the full cluster mass range. G0.253+0.016 is an excellent candidate YMC progenitor. We make use of existing multi-wavelength data including recently available far-IR continuum (Herschel/Hi-GAL) and mm spectral line (HOPS and MALT90) data and present new, deep, multiple-filter, near-IR (VLT/NACO) observations to study G0.253+0.016. These data show G0.253+0.016 is a high mass (1.3x10^5 Msun), low temperature (T_dust~20K), high volume and column density (n ~ 8x10^4 cm^-3; N_{H_2} ~ 4x10^23 cm^-2) molecular clump which is close to virial equilibrium (M_dust ~ M_virial) so is likely to be gravitationally-bound. It is almost devoid of star formation and, thus, has exactly the properties expected for the initial conditions of a clump that may form an Arches-like massive cluster. We compare the properties of G0.253+0.016 to typical Galactic cluster-forming molecular clumps and find it is extreme, and possibly unique in the Galaxy. This uniqueness makes detailed studies of G0.253+0.016 extremely important for testing massive cluster formation models.

astro-ph.GA↗

The Fringe Detection Laser Metrology for the GRAVITY Interferometer at the VLTI

Interferometric measurements of optical path length differences of stars over large baselines can deliver extremely accurate astrometric data. The interferometer GRAVITY will simultaneously measure two objects in the field of view of the Very Large Telescope Interferometer (VLTI) of the European Southern Observatory (ESO) and determine their angular separation to a precision of 10 micro arcseconds in only 5 minutes. To perform the astrometric measurement with such a high accuracy, the differential path length through the VLTI and the instrument has to be measured (and tracked since Earth's rotation will permanently change it) by a laser metrology to an even higher level of accuracy (corresponding to 1 nm in 3 minutes). Usually, heterodyne differential path techniques are used for nanometer precision measurements, but with these methods it is difficult to track the full beam size and to follow the light path up to the primary mirror of the telescope. Here, we present the preliminary design of a differential path metrology system, developed within the GRAVITY project. It measures the instrumental differential path over the full pupil size and up to the entrance pupil location. The differential phase is measured by detecting the laser fringe pattern both on the telescopes' secondary mirrors as well as after reflection at the primary mirror. Based on our proposed design we evaluate the phase measurement accuracy based on a full budget of possible statistical and systematic errors. We show that this metrology design fulfills the high precision requirement of GRAVITY.

astro-ph.IM↗

GRAVITY: a four-telescope beam combiner instrument for the VLTI

GRAVITY is an adaptive optics assisted Beam Combiner for the second generation VLTI instrumentation. The instrument will provide high-precision narrow-angle astrometry and phase-referenced interferometric imaging in the astronomical K-band for faint objects. We describe the wide range of science that will be tackled with this instrument, highlighting the unique capabilities of the VLTI in combination with GRAVITY. The most prominent goal is to observe highly relativistic motions of matter close to the event horizon of Sgr A*, the massive black hole at center of the Milky Way. We present the preliminary design that fulfils the requirements that follow from the key science drivers: It includes an integrated optics, 4-telescope, dual feed beam combiner operated in a cryogenic vessel; near-infrared wavefrontsensing adaptive optics; fringe-tracking on secondary sources within the field of view of the VLTI and a novel metrology concept. Simulations show that 10 μas astrometry within few minutes is feasible for a source with a magnitude of mK = 15 like Sgr A*, given the availability of suitable phase reference sources (mK = 10). Using the same setup, imaging of mK = 18 stellar sources in the interferometric field of view is possible, assuming a full night of observations and the corresponding UV coverage of the VLTI.

astro-ph.IM↗

Expected Performance of the ATLAS Experiment - Detector, Trigger and Physics

A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on simulations of the detector and physics processes, with particular emphasis given to the data expected from the first years of operation of the LHC at CERN.

hep-ex↗

Uncovering the kiloparsec-scale stellar ring of NGC5128

We reveal the stellar light emerging from the kiloparsec-scale, ring-like structure of the NGC5128 (Centaurus A) galaxy in unprecedented detail. We use arcsecond-scale resolution near infrared images to create a "dust-free" view of the central region of the galaxy, which we then use to quantify the shape of the revealed structure. At the resolution of the data, the structure contains several hundreds of discreet, point-like or slightly elongated sources. Typical extinction corrected surface brightness of the structure is K_S = 16.5 mag/arcsec^2, and we estimate the total near infrared luminosity of the structure to be M = -21 mag. We use diffraction limited (FWHM resolution of ~ 0.1", or 1.6 pc) near infrared data taken with the NACO instrument on VLT to show that the structure decomposes into thousands of separate, mostly point-like sources. According to the tentative photometry, the most luminous sources have M_K = -12 mag, naming them red supergiants or relatively low-mass star clusters. We also discuss the large-scale geometry implied by the reddening signatures of dust in our near infrared images.

astro-ph.GA↗

System overview of the VLTI Spectro-Imager

The VLTI Spectro Imager project aims to perform imaging with a temporal resolution of 1 night and with a maximum angular resolution of 1 milliarcsecond, making best use of the Very Large Telescope Interferometer capabilities. To fulfill the scientific goals (see Garcia et. al.), the system requirements are: a) combining 4 to 6 beams; b) working in spectral bands J, H and K; c) spectral resolution from R= 100 to 12000; and d) internal fringe tracking on-axis, or off-axis when associated to the PRIMA dual-beam facility. The concept of VSI consists on 6 sub-systems: a common path distributing the light between the fringe tracker and the scientific instrument, the fringe tracker ensuring the co-phasing of the array, the scientific instrument delivering the interferometric observables and a calibration tool providing sources for internal alignment and interferometric calibrations. The two remaining sub-systems are the control system and the observation support software dedicated to the reduction of the interferometric data. This paper presents the global concept of VSI science path including the common path, the scientific instrument and the calibration tool. The scientific combination using a set of integrated optics multi-way beam combiners to provide high-stability visibility and closure phase measurements are also described. Finally we will address the performance budget of the global VSI instrument. The fringe tracker and scientific spectrograph will be shortly described.

astro-ph↗

VSI: the VLTI spectro-imager

The VLTI Spectro Imager (VSI) was proposed as a second-generation instrument of the Very Large Telescope Interferometer providing the ESO community with spectrally-resolved, near-infrared images at angular resolutions down to 1.1 milliarcsecond and spectral resolutions up to R=12000. Targets as faint as K=13 will be imaged without requiring a brighter nearby reference object. The unique combination of high-dynamic-range imaging at high angular resolution and high spectral resolution enables a scientific program which serves a broad user community and at the same time provides the opportunity for breakthroughs in many areas of astrophysic including: probing the initial conditions for planet formation in the AU-scale environments of young stars; imaging convective cells and other phenomena on the surfaces of stars; mapping the chemical and physical environments of evolved stars, stellar remnants, and stellar winds; and disentangling the central regions of active galactic nuclei and supermassive black holes. VSI will provide these new capabilities using technologies which have been extensively tested in the past and VSI requires little in terms of new infrastructure on the VLTI. At the same time, VSI will be able to make maximum use of new infrastructure as it becomes available; for example, by combining 4, 6 and eventually 8 telescopes, enabling rapid imaging through the measurement of up to 28 visibilities in every wavelength channel within a few minutes. The current studies are focused on a 4-telescope version with an upgrade to a 6-telescope one. The instrument contains its own fringe tracker and tip-tilt control in order to reduce the constraints on the VLTI infrastructure and maximize the scientific return.

astro-ph↗

Milli-arcsecond astrophysics with VSI, the VLTI spectro-imager in the ELT era

Nowadays, compact sources like surfaces of nearby stars, circumstellar environments of stars from early stages to the most evolved ones and surroundings of active galactic nuclei can be investigated at milli-arcsecond scales only with the VLT in its interferometric mode. We propose a spectro-imager, named VSI (VLTI spectro-imager), which is capable to probe these sources both over spatial and spectral scales in the near-infrared domain. This instrument will provide information complementary to what is obtained at the same time with ALMA at different wavelengths and the extreme large telescopes.

astro-ph↗

HERA-B Framework for Online Calibration and Alignment

This paper describes the architecture and implementation of the HERA-B framework for online calibration and alignment. At HERA-B the performance of all trigger levels, including the online reconstruction, strongly depends on using the appropriate calibration and alignment constants, which might change during data taking. A system to monitor, recompute and distribute those constants to online processes has been integrated in the data acquisition and trigger systems.

hep-ex↗

Experience with the Open Source based implementation for ATLAS Conditions Data Management System

Conditions Data in high energy physics experiments is frequently seen as every data needed for reconstruction besides the event data itself. This includes all sorts of slowly evolving data like detector alignment, calibration and robustness, and data from detector control system. Also, every Conditions Data Object is associated with a time interval of validity and a version. Besides that, quite often is useful to tag collections of Conditions Data Objects altogether. These issues have already been investigated and a data model has been proposed and used for different implementations based in commercial DBMSs, both at CERN and for the BaBar experiment. The special case of the ATLAS complex trigger that requires online access to calibration and alignment data poses new challenges that have to be met using a flexible and customizable solution more in the line of Open Source components. Motivated by the ATLAS challenges we have developed an alternative implementation, based in an Open Source RDBMS. Several issues were investigated land will be described in this paper: -The best way to map the conditions data model into the relational database concept considering what are foreseen as the most frequent queries. -The clustering model best suited to address the scalability problem. -Extensive tests were performed and will be described. The very promising results from these tests are attracting the attention from the HEP community and driving further developments.

cs.DB↗