SearcharxivSearch

arXiv subjects

A. Andres

Publications and source records attributed to A. Andres.

8 recordsLinked to original sources

First Experimental Limit on the Permanent Electric Dipole Moment of the Deuteron

Permanent electric dipole moments (EDMs) provide a sensitive probe of physics beyond the Standard Model and are directly linked to additional sources of CP violation that could explain the matter-antimatter asymmetry of the universe. EDM measurements of charged particles in storage rings rely on detecting a small tilt of the invariant spin axis with respect to the ring plane. In this work, we present the experimental determination of the invariant spin axis of an ensemble of deuterons in the COoler SYnchrotron (COSY), a conventional magnetic storage ring, using a combination of a radio-frequency Wien filter, a superconducting Siberian snake and an electron-cooler solenoid. The measurements reveal tilts of a few milliradians, which are dominated by systematic effects. From the observed tilts, we derive the first experimental limit on the deuteron EDM, $|d^d|< 2.5\cdot10^{-17}\,e\cdot\mathrm{cm} \; (95\%\,\text{ C.L.})$. This result demonstrates the feasibility of using storage rings to search for EDMs of charged stable hadrons and provides a foundation for future dedicated facilities.

nucl-ex

Constraints on Axion-Like Particles from Ultra-High-Energy Observations of 3HWC J1908+063 with HAWC

Axion-like particles (ALPs) are hypothetical particles and compelling candidates for cold dark matter. Their existence could be probed through their conversions into photons in the presence of magnetic fields. In this work, we explore the effect of these photon-ALP conversions by searching for an attenuation in the observed gamma ray spectra of galactic sources that emit at energies of hundreds of TeV. We analyze data from the High-Altitude Water Cherenkov (HAWC) Observatory for the source 3HWC J1908+063. No evidence of photon-ALP conversions was found, and we set constraints on the ALP parameter space. Specifically, we derive exclusion limits for ALPs with masses in the range $10^{-8}~\mathrm{eV} \leq m_a \leq 10^{-6}~\mathrm{eV}$ and photon-ALP couplings in the range $10^{-12}~\mathrm{GeV}^{-1} \leq g_{a\gamma} \leq 10^{-10}~\mathrm{GeV}^{-1}$, based on HAWC observations.

astro-ph.HE

Maintaining a Resonance Condition of an RF Spin Rotator Through a Feedback Loop in a Storage Ring

This paper presents the successful application of a phase-lock feedback system to maintain the resonance condition of a radio frequency (rf) spin rotator (specifically, an rf Wien filter) with respect to a 120 kHz spin precession in the Cooler Synchrotron (COSY) storage ring. Real-time monitoring of the spin precession and the rf Wien filter signal allows the relative phase between the two to be stabilized at an arbitrary setpoint. The feedback system compensates for deviations in the relative phase by adjusting the frequency and/or phase as needed. With this method, a variation in phase relative to the demand phase with a standard deviation of $\sigma_{\Delta\varphi}\approx 0.2\mathrm{rad}$ could be achieved. The system was implemented in two runs aiming at a first direct measurement of the deuteron electric dipole moment in 2018 and 2021. In addition, the difference between a single-bunch beam affected by the spin rotator and a two-bunch system in which only one bunch is exposed to the spin rotator fields is discussed. Both methods have been used during these beam times. The ability to keep the spin precession and the rf fields synchronized is also crucial for future investigations of electric dipole moments of charged particles using storage rings.

physics.acc-ph

Spin decoherence and off-resonance behavior of radiofrequency-driven spin rotations in storage rings

Radiofrequency-driven resonant spin rotators are routinely used as standard instruments in polarization experiments in particle and nuclear physics. Maintaining the continuous exact parametric spin-resonance condition of the equality of the spin rotator and the spin precession frequency during operation constitutes one of the challenges. We present a detailed analytic description of the impact of detuning the exact spin resonance on the vertical and the in-plane precessing components of the polarization. An important part of the formalism presented here is the consideration of experimentally relevant spin-decoherence effects. We discuss applications of the developed formalism to the interpretation of the experimental data on the novel pilot bunch approach to control the spin-resonance condition during the operation of the radiofrequency-driven Wien filter that is used as a spin rotator in the first direct deuteron electric dipole moment measurement at COSY. We emphasize the potential importance of the hitherto unexplored phase of the envelope of the horizontal polarization as an indicator of the stability of the radiofrequency-driven spin rotations in storage rings. The work presented here serves as a satellite publication to the work published concurrently on the proof of principle experiment about the so-called pilot bunch approach that was developed to provide co-magnetometry for the deuteron electric dipole moment experiment at COSY.

physics.acc-ph

Pilot bunch and co-magnetometry of polarized particles stored in a ring

In polarization experiments at storage rings, one of the challenges is to maintain the spin-resonance condition of a radio-frequency spin rotator with the spin-precessions of the orbiting particles. Time-dependent variations of the magnetic fields of ring elements lead to unwanted variations of the spin precession frequency. We report here on a solution to this problem by shielding (or masking) one of the bunches stored in the ring from the high-frequency fields of the spin rotator, so that the masked pilot bunch acts as a co-magnetometer for the other signal bunch, tracking fluctuations in the ring on a time scale of about one second. While the new method was developed primarily for searches of electric dipole moments of charged particles, it may have far-reaching implications for future spin physics facilities, such as the EIC and NICA.

physics.ins-det

First detection of collective oscillations of a stored deuteron beam with an amplitude close to the quantum limit

We investigated coherent betatron oscillations of a deuteron beam in the storage ring COSY, excited by a detuned radio-frequency Wien filter. The beam oscillations were detected by conventional beam position monitors. With the currently available apparatus, we show that oscillation amplitudes down to \SI{1}{\micro \meter} can be detected. The interpretation of the response of the stored beam to the detuned radio-frequency Wien filter is based on simulations of the beam evolution in the lattice of the ring and realistic time-dependent 3D field maps of the Wien filter. Future measurements of the electric dipole moment of protons will, however, require control of the relative position of counter-propagating beams in the sub-picometer range. Since here the stored beam can be considered as a rarefied gas of uncorrelated particles, we moreover demonstrate that the amplitudes of the zero-point (ground state) betatron oscillations of individual particles are only a factor of about 10 larger than the Heisenberg uncertainty limit. As a consequence of this, we conclude that quantum mechanics does not preclude the control of the beam centroids to sub-picometer accuracy. The smallest Lorentz force exerted on a single particle that we have been able to determine is \SI{10}{aN}.

nucl-ex

Beam-based alignment at the Cooler Synchrotron COSY as a prerequisite for an electric dipole moment measurement

The Jülich Electric Dipole moment Investigation (JEDI) collaboration aims at a direct measurement of the Electric Dipole Moment (EDM) of protons and deuterons using a storage ring. The measurement is based on a polarization measurement. In order to reach highest accuracy, one has to know the exact trajectory through the magnets, especially the quadrupoles, to avoid the influence of magnetic fields on the polarization vector. In this paper, the development of a beam-based alignment technique is described that was developed and implemented at the COoler SYnchrotron (COSY) at Forschungszentrum Jülich. Well aligned quadrupoles permit one to absolutely calibrate the Beam Position Monitors (BPMs). The method is based on the fact that a particle beam, which does not pass through the center of a quadrupole, experiences a deflection. The precision reached by the method is approximately 40 micro meter. Some consequences for the design of a new high precision storage ring for EDM mesasurements are discussed.

physics.acc-ph

Storage Ring to Search for Electric Dipole Moments of Charged Particles -- Feasibility Study

The proposed method exploits charged particles confined as a storage ring beam (proton, deuteron, possibly $^3$He) to search for an intrinsic electric dipole moment (EDM) aligned along the particle spin axis. Statistical sensitivities could approach 10$^{-29}$ e$\cdot$cm. The challenge will be to reduce systematic errors to similar levels. The ring will be adjusted to preserve the spin polarisation, initially parallel to the particle velocity, for times in excess of 15 minutes. Large radial electric fields, acting through the EDM, will rotate the polarisation from the longitudinal to the vertical direction. The slow rise in the vertical polarisation component, detected through scattering from a target, signals the EDM. The project strategy is outlined. A stepwise plan is foreseen, starting with ongoing COSY activities that demonstrate technical feasibility. Achievements to date include reduced polarization measurement errors, long horizontal plane polarization lifetimes, and control of the polarization direction through feedback from scattering measurements. The project continues with a proof-of-capability measurement (precursor experiment; first direct deuteron EDM measurement), an intermediate prototype ring (proof-of-principle; demonstrator for key technologies), and finally a high-precision electric-field storage ring.

hep-ex