SearcharxivSearch

arXiv subjects

A. Antognini

Publications and source records attributed to A. Antognini.

At least 19 recordsLinked to original sources

The MuFusE Large-Volume Diamond Anvil Cell for Exploring Muon-Catalyzed Fusion at Higher Pressures and Temperatures

A new large-volume diamond anvil cell (DAC) has been developed for the Muon-catalyzed Fusion ($\mu$CF) Experiment (MuFusE), enabling the compression and heating of deuterium-tritium (d-t) mixtures to pressures and temperatures needed to advance $\mu$CF research. The MuFusE DAC achieves the large sample volumes necessary for high-precision fusion measurements while integrating cryogenic loading, all-metal sealing, and flexible bellows to maintain a secure environment during cell compression. Combined with remote pneumatic actuation and secondary containment, the DAC safely managed a 25 Ci tritium inventory while providing a clear optical path for in situ measurements of sample pressure and composition via laser spectroscopy. Utilizing 5 mm diameter diamond anvils oriented in the path of a high-intensity muon beam, the apparatus achieved a stable sample volume of 19.2 mm$^3$ at liquid density, pressures up to 933 MPa and temperatures up to 400 K - benchmarks that significantly exceed previously reported limits for static d-t targets.

physics.ins-det

Laser Excitation of Muonic 1S Hydrogen Hyperfine Transition: Effects of Multi-pass Cell Interference

Calculating the laser-induced transition probability by using the fluence distribution that neglects interference effects (e.g., by employing ray-tracing methods) can lead to an overestimation of this probability, as it underestimates saturation effects. In this paper, we investigate how interference effects in the multi-pass cell, used to enhance the laser fluence, affect the laser-induced transition probability between hyperfine levels in muonic hydrogen, a bound system of a negative muon and a proton. To avoid complications related to the exact knowledge of the intra-cavity field, we develop a simple model that estimates the maximal possible interference effects for given laser and multi-pass cell parameters, thereby providing an upper bound for the resulting decrease in transition probability relative to the case where these effects are neglected. A numerical evaluation of this upper bound for muonic hydrogen shows that, under our experimental conditions, such effects can be safely neglected. Nonetheless, the methodology presented here could be applied to estimate the impact of interference effects on the laser-induced transition probability in other experiments involving coherent light in multi-pass systems.

physics.atom-ph

Phase space compression of a positive muon beam in two spatial dimensions

We present the first demonstration of simultaneous phase space compression in two spatial dimensions of a positive muon beam, the first stage of the novel high-brightness muon beam under development by the muCool collaboration at the Paul Scherrer Institute. The keV-energy, sub-mm size beam would enable a factor 10$^5$ improvement in brightness for precision muSR, and atomic and particle physics measurements with positive muons. This compression is achieved within a cryogenic helium gas target with a strong density gradient, placed in a homogeneous magnetic field, under the influence of a complex electric field. In the next phase, the muon beam will be extracted into vacuum.

physics.acc-ph

Muonic atom spectroscopy with microgram target material

Muonic atom spectroscopy -- the measurement of the x rays emitted during the formation process of a muonic atom -- has a long standing history in probing the shape and size of nuclei. In fact, almost all stable elements have been subject to muonic atom spectroscopy measurements and the absolute charge radii extracted from these measurements typically offer the highest accuracy available. However, so far only targets of at least a few hundred milligram could be used as it required to stop a muon beam directly in the target to form the muonic atom. We have developed a new method relying on repeated transfer reactions taking place inside a 100-bar hydrogen gas cell with an admixture of 0.25% deuterium that allows us to drastically reduce the amount of target material needed while still offering an adequate efficiency. Detailed simulations of the transfer reactions match the measured data, suggesting good understanding of the processes taking place inside the gas mixture. As a proof of principle we demonstrate the method with a measurement of the 2p-1s muonic x rays from a 5-μg gold target.

nucl-ex

Diffusion of muonic hydrogen in hydrogen gas and the measurement of the 1$s$ hyperfine splitting of muonic hydrogen

The CREMA collaboration is pursuing a measurement of the ground-state hyperfine splitting (HFS) in muonic hydrogen ($μ$p) with 1 ppm accuracy by means of pulsed laser spectroscopy. In the proposed experiment, the $μ$p atom is excited by a laser pulse from the singlet to the triplet hyperfine sub-levels, and is quenched back to the singlet state by an inelastic collision with a H$_2$ molecule. The resulting increase of kinetic energy after this cycle modifies the $μ$p atom diffusion in the hydrogen gas and the arrival time of the $μ$p atoms at the target walls. This laser-induced modification of the arrival times is used to expose the atomic transition. In this paper we present the simulation of the $μ$p diffusion in the H$_2$ gas which is at the core of the experimental scheme. These simulations have been implemented with the Geant4 framework by introducing various low-energy processes including the motion of the H$_2$ molecules, i.e. the effects related with the hydrogen target temperature. The simulations have been used to optimize the hydrogen target parameters (pressure, temperatures and thickness) and to estimate signal and background rates. These rates allow to estimate the maximum time needed to find the resonance and the statistical accuracy of the spectroscopy experiment.

physics.atom-ph

Room-temperature emission of muonium from aerogel and zeolite targets

A low-emittance, high-intensity atomic beam of muonium ($\mathrm{M}=μ^+ + \mathrm{e}^-$) using superfluid helium as muon-to-muonium converter is being developed at the Paul Scherrer Institute (PSI). This beam could advance laser spectroscopy of muonium and allow the first atomic interferometry experiments for the direct observation of the M gravitational interaction. In this paper, we describe the development of compact detection schemes which resulted in the background-suppressed observation of atomic muonium in vacuum, and can be adapted for cryogenic measurements. Using these setups, we compared the emission characteristics of various muonium production targets using low momentum ($p_μ = 11$-$13~$MeV/c) muons, and observed muonium emission from zeolite targets into vacuum for the first time. For a specific laser-ablated aerogel target, we determined a muon-to-vacuum-muonium conversion efficiency of $7.23 \pm 0.05 \text{(stat)} ^{+1.06}_{-0.76}\text{(sys)}\,\text{%}$, assuming thermal emission of muonium. Moreover, we investigated muonium-helium collisions and from it we determined an upper temperature limit of 0.3 K for the superfluid helium converter.

physics.atom-ph

Laser excitation of the 1s-hyperfine transition in muonic hydrogen

The CREMA collaboration is pursuing a measurement of the ground-state hyperfine splitting (HFS) in muonic hydrogen ($μ$p) with 1 ppm accuracy by means of pulsed laser spectroscopy to determine the two-photon-exchange contribution with $2\times10^{-4}$ relative accuracy. In the proposed experiment, the $μ$p atom undergoes a laser excitation from the singlet hyperfine state to the triplet hyperfine state, {then} is quenched back to the singlet state by an inelastic collision with a H$_2$ molecule. The resulting increase of kinetic energy after the collisional deexcitation is used as a signature of a successful laser transition between hyperfine states. In this paper, we calculate the combined probability that a $μ$p atom initially in the singlet hyperfine state undergoes a laser excitation to the triplet state followed by a collisional-induced deexcitation back to the singlet state. This combined probability has been computed using the optical Bloch equations including the inelastic and elastic collisions. Omitting the decoherence effects caused by {the laser bandwidth and }collisions would overestimate the transition probability by more than a factor of two in the experimental conditions. Moreover, we also account for Doppler effects and provide the matrix element, the saturation fluence, the elastic and inelastic collision rates for the singlet and triplet states, and the resonance linewidth. This calculation thus quantifies one of the key unknowns of the HFS experiment, leading to a precise definition of the requirements for the laser system and to an optimization of the hydrogen gas target where $μ$p is formed and the laser spectroscopy will occur.

physics.atom-ph

Improving position resolution of neutron detectors with ultra-thin B4C foils

A new technique for detection of slow neutrons with gaseous detectors using ultra-thin layers with 10B atoms is presented. The reaction between a thermal neutron and a 10B atom releases 2 secondary particles, namely a 7Li ion and an alpha particle, which due to momentum conservation are emitted in opposite directions, along the same line (back to back). Current boron coated neutron detectors are equipped with 10B films with thicknesses of several micrometers, deposited on very thick substrate plates. However, since the ranges of the 7Li ion and the alpha particle are of few micrometeres in most materials, one of these particles is always lost in the 10B layer or substrate. As such, these detectors lose the ability to reconstruct the reaction line of action and to precisely determine the neutron position, as only one of the two secondary particles track can be measured. With the technique now presented, the sum of the 10B layer and the substrate thicknesses is small enough to allow for both secondary particles to escape and ionize the gas in opposite sides of the 10B converter foil. Independent readout structures, one on each side of the 10B converter foil, detect each secondary particle and determine its track centroid and the deposited energy. Since the two secondary particles are emitted back to back, the neutron position can be obtained by combining the information recorded by the two readout structures. Through GEANT4 simulations, we verified that the spatial resolution can be significantly improved: our results show that, by using a B4C layer with a thickness of 1 micron on a 0.9 micron Mylar substrate, the spatial resolution can by improved by a factor of 8, compared to conventional detectors with thick 10B detection layers.

physics.ins-det

Science Case for the new High-Intensity Muon Beams HIMB at PSI

In April 2021, scientists active in muon physics met to discuss and work out the physics case for the new High-Intensity Muon Beams (HIMB) project at PSI that could deliver of order $10^{10}$\,s$^{-1}$ surface muons to experiments. Ideas and concrete proposals were further substantiated over the following months and assembled in the present document. The high intensities will allow for completely new experiments with considerable discovery potential and unique sensitivities. The physics case is outstanding and extremely rich, ranging from fundamental particle physics via chemistry to condensed matter research and applications in energy research and elemental analysis. In all these fields, HIMB will ensure that the facilities S$μ$S and CHRISP on PSI's High Intensity Proton Accelerator complex HIPA remain world-leading, despite the competition of muon facilities elsewhere.

hep-ex

Demonstration of Muon-Beam Transverse Phase-Space Compression

We demonstrate efficient transverse compression of a 12.5 MeV/c muon beam stopped in a helium gas target featuring a vertical density gradient and crossed electric and magnetic fields. The muon stop distribution extending vertically over 14 mm was reduced to a 0.25 mm size (RMS) within 3.5 $μ$s. The simulation including cross sections for low-energy $μ^+$-$\text{He}$ elastic and charge exchange ($μ^+\leftrightarrow $ muonium) collisions describes the measurements well. By combining the transverse compression stage with a previously demonstrated longitudinal compression stage, we can improve the phase space density of a $μ^+ $ beam by a factor of $ 10^{10} $ with $ 10^{-3} $ efficiency.

physics.acc-ph

The measurement of the quadrupole moment of 185-Re and 187-Re from the hyperfine structure of muonic X rays

The hyperfine splitting of the 5g -> 4f transitions in muonic 185,187-Re has been measured using high resolution HPGe detectors and compared to state-of-the-art atomic theoretical predictions. The spectroscopic quadrupole moment has been extracted using modern fitting procedures and compared to the values available in literature obtained from muonic X rays of natural rhenium. The extracted values of the nuclear spectroscopic quadrupole moment are 2.07(5) barn and 1.94(5) barn, respectively for 185-Re and 187-Re. This work is part of a larger effort at the Paul Scherrer Institut towards the measurement of the nuclear charge radii of radioactive elements.

nucl-ex

muCool: A novel low-energy muon beam for future precision experiments

Experiments with muons ($μ^{+}$) and muonium atoms ($μ^{+}e^{-}$) offer several promising possibilities for testing fundamental symmetries. Examples of such experiments include search for muon electric dipole moment, measurement of muon $g-2$ and experiments with muonium from laser spectroscopy to gravity experiments. These experiments require high quality muon beams with small transverse size and high intensity at low energy. At the Paul Scherrer Institute, Switzerland, we are developing a novel device that reduces the phase space of a standard $μ^{+}$ beam by a factor of $10^{10}$ with $10^{-3}$ efficiency. The phase space compression is achieved by stopping a standard $μ^{+}$ beam in a cryogenic helium gas. The stopped $μ^{+}$ are manipulated into a small spot with complex electric and magnetic fields in combination with gas density gradients. From here, the muons are extracted into the vacuum and into a field-free region. Various aspects of this compression scheme have been demonstrated. In this article the current status will be reported.

physics.acc-ph

Compact 20-pass thin-disk amplifier insensitive to thermal lensing

We present a multi-pass amplifier which passively compensates for distortions of the spherical phase front occurring in the active medium. The design is based on the Fourier transform propagation which makes the output beam parameters insensitive to variation of thermal lens effects in the active medium. The realized system allows for 20 reflections on the active medium and delivers a small signal gain of 30 with M$^2$ = 1.16. Its novel geometry combining Fourier transform propagations with 4f-imaging stages as well as a compact array of adjustable mirrors allows for a layout with a footprint of 400 mm x 1000 mm.

physics.optics

muCool: A next step towards efficient muon beam compression

A novel device to compress the phase space of a muon beam by a factor of $10^{10}$ with a $10^{-3}$ efficiency is under development. A surface muon beam is stopped in a helium gas target consisting of several compression stages, wherein strong electric and magnetic fields are applied. The spatial extent of the stopped muon swarm is decreased by means of these fields until muons with eV energy are extracted into vacuum through a small orifice. It was measured that a 20 cm long muon stop distribution can be compressed in longitudinal direction to sub-mm extent within 2 ${\rm μs}$. Additionally, a drift perpendicular to the magnetic field of the compressed low-energy muon swarm was successfully demonstrated, paving the way towards the extraction from the gas and re-acceleration of the muons.

physics.acc-ph

The next generation of laser spectroscopy experiments using light muonic atoms

Precision spectroscopy of light muonic atoms provides unique information about the atomic and nuclear structure of these systems and thus represents a way to access fundamental interactions, properties and constants. One application comprises the determination of absolute nuclear charge radii with unprecedented accuracy from measurements of the 2S$\,$-$\,$2P Lamb shift. Here, we review recent results of nuclear charge radii extracted from muonic hydrogen and helium spectroscopy and present experiment proposals to access light muonic atoms with $Z \geq 3$. In addition, our approaches towards a precise measurement of the Zemach radii in muonic hydrogen ($μ$p) and helium ($μ$$^{3}$He$^{+}$) are discussed. These results will provide new tests of bound-state quantum-electrodynamics in hydrogen-like systems and can be used as benchmarks for nuclear structure theories.

physics.atom-ph

The proton radius puzzle

High-precision measurements of the proton radius from laser spectroscopy of muonic hydrogen demonstrated up to six standard deviations smaller values than obtained from electron-proton scattering and hydrogen spectroscopy. The status of this discrepancy, which is known as the proton radius puzzle will be discussed in this paper, complemented with the new insights obtained from spectroscopy of muonic deuterium.

physics.atom-ph

Spatial confinement of muonium atoms

We report the achievement of spatial confinement of muonium atoms (the bound state of a positive muon and an electron). Muonium emitted into vacuum from mesoporous silica reflects between two SiO$_2$ confining surfaces separated by 1 mm. From the data, one can extract that the reflection probability on the confining surfaces kept at 100 K is about 90% and the reflection process is well described by a cosine law. This technique enables new experiments with this exotic atomic system and is a very important step towards a measurement of the 1S-2S transition frequency using continuous wave laser spectroscopy.

physics.atom-ph

Multi-pass oscillator layout for high-energy mode-locked thin-disk lasers

A novel optical layout for a multi-pass resonator is presented paving the way for pulse energy scaling of mode-locked thin-disk lasers. The multi-pass resonator we are proposing consists of a concatenation of nearly identical optical segments. Each segment corresponds to a round-trip in an optically stable cavity containing an active medium exhibiting soft aperture effects. This scheme is apt for energy and power scaling because the stability region of this multi-pass resonator contrarily to the 4f-based schemes does not shrink with the number of passes. Simulation of the eigen-mode of this multi-segment resonator requires considering aperture effects. This has been achieved by implementing effective Gaussian apertures into the ABCD-matrix formalism as lenses with imaginary focal length. We conclude proposing a simple way to double the stability region of the state-of-the-art layouts used in industry achievable by a minimal rearrangement of the used optical components.

physics.optics