SearcharxivSearch

arXiv subjects

A. Apponi

Publications and source records attributed to A. Apponi.

6 recordsLinked to original sources

Towards Low-Energy Electron High-Resolution Spectroscopy with Transition-Edge Sensors

We present a study of the energy resolution of transition-edge sensors (TESs) for the detection of electrons in the 100 eV kinetic energy range. The TES is a Ti-Au bilayer with an active area of $(60 \times 60)$ $\mu \text{m}^2$ and a critical temperature of $\sim$ 80 mK. The electron source is based on vertically-aligned multiwall carbon nanotubes located inside the cryostat, with electrons generated via field emission. For electrons in the (92 - 99) eV kinetic energy range, we obtain a Gaussian energy resolution for fully-absorbed electrons of (0.479 $\pm$ 0.041 $\pm$ 0.055) eV. When considering the full-width at half-maximum of the peak, the corresponding resolution is of (1.44 $\pm$ 0.17 $\pm$ 0.27) eV. The former represents an improvement of (46 - 60)% with respect to previous results, and is mainly attributed to the reduction in the TES active area. The latter is instead an improvement of over a factor of 20, and is mainly due to the reduction in the emitting area of the electron source, which significantly suppresses electron back-scattering in proximity of the TES. These results represent a major milestone toward high-precision spectroscopy on low-energy electrons, which is a key objective for the PTOLEMY experiment.

physics.ins-det

Ultra-high precision high voltage system for PTOLEMY

The PTOLEMY project is prototyping a novel electromagnetic filter for high-precision $\beta$ spectroscopy, with the ultimate and ambitious long-term goal of detecting the cosmic neutrino background through electron capture on tritium bound to graphene. Intermediate small-scale prototypes can achieve competitive sensitivity to the effective neutrino mass, even with reduced energy resolution. To reach an energy resolution better than \SI{500}{meV} at the tritium $\beta$-spectrum endpoint of \SI{18.6}{keV}, and accounting for all uncertainties in the filtering chain, the electrode voltage must be controlled at the level of a few parts per million and monitored in real time. In this work, we present the first results obtained in this effort, using a chain of commercial ultra-high-precision voltage references, read out by precision multimeters and a \emph{field mill} device. The currently available precision on high voltage is, in the conservative case, as low as \SI{0.2}{ppm} per \SI{1}{kV} single board and $\lesssim$ \SI{50}{mV} over the \SI{10}{kV} series, presently limited by field mill read-out noise. However, assuming uncorrelated Gaussian noise extrapolation, the real precision could in principle be as low as \SI{0.05}{ppm} over \SI{20}{kV}.

physics.ins-det

A Demonstration of Slowed Electron ${\bf E} \times {\bf B}$ Drift for PTOLEMY

To resolve the effective neutrino mass $m_\beta$ with an energy resolution of 50~meV, the PTOLEMY experiment has proposed a novel transverse electromagnetic filtering process. Substantially reducing the kinetic energy of tritium $\beta$-decay electrons by counteracting motion from ${\bf E}$ $\times$ ${\bf B}$ and $\nabla{\rm B}$ drift, the PTOLEMY filter requires an input of emitted electron kinematic information to generate a tailored, suitable electric field for each candidate. The collaboration proposes to extract these quantities by using antennae to observe the relativistic frequency shift of emitted cyclotron radiation as an electron transits by ${\bf E}$ $\times$ ${\bf B}$ drift through a uniform magnetic field region preceding the filter. Electrons must be contained within this region long enough such that an adequate integrated radiated power signal is received to accurately estimate these kinematics. This necessitates a controlled, slowed drift speed. This paper presents the experimental design to vary ${\bf E}$ $\times$ ${\bf B}$ drift speed of carbon-14 $\beta$-decay electrons using a custom electrode field cage situated between the pole faces of an electromagnet. Matching our results with high-fidelity simulation, we deduce a capacity to increase particle time of flight by a factor of 5 in the field cage's slow drift region. Limited only by the dimensions of our system, we assert drift speed can be arbitrarily slowed to meet the needs of PTOLEMY's future detector. Actualizing such a system is a crucial milestone in developing the detector, enabling future cyclotron radiation measurements, filter implementation, and source injection.

physics.ins-det

Absolute efficiency of a two-stage microchannel plate for electrons in the 30 - 900 eV energy range

We report on an apparatus able to measure the absolute detection efficiency of a detector for electrons in the 30 - 900 eV range. In particular, we discuss the characterisation of a two-stage chevron microchannel plate (MCP). The measurements have been performed in the LASEC laboratory at Roma Tre University, whit a custom-made electron gun. The very good stability of the beam current in the fA range, together with the picoammeter nominal resolution of 0.01 fA, allowed the measurement of the MCP absolute efficiency $\epsilon$. We found an $\epsilon$ = (0.489 $\pm$ 0.003) with no evident energy dependence. We fully characterised the MCP pulse shape distribution, which is quasi-Gaussian with a well visible peak above the noise level. We measured a 68% variation of the average pulse height between 30 and 500 eV. Furthermore, with a deeper analysis of the pulse shape, and in particular of the correlation between pulse height, area and width, we found a method to discriminate single- and multi- electron events occurring within a 10 ns time window.

physics.ins-det

Heisenberg's uncertainty principle in the PTOLEMY project: a theory update

We discuss the consequences of the quantum uncertainty on the spectrum of the electron emitted by the $\beta$-processes of a tritium atom bound to a graphene sheet. We analyze quantitatively the issue recently raised in [Cheipesh et al., Phys. Rev. D 104, 116004 (2021)], and discuss the relevant time scales and the degrees of freedom that can contribute to the intrinsic spread in the electron energy. We perform careful calculations of the potential between tritium and graphene with different coverages and geometries. With this at hand, we propose possible avenues to mitigate the effect of the quantum uncertainty.

hep-ph

Implementation and Optimization of the PTOLEMY Transverse Drift Electromagnetic Filter

The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium beta-decay endpoint. This paper details the implementation and optimization methods for successful operation of the filter. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the setting of filter electrode voltages are detailed. The challenges of low-energy electron transport in cases of low field are discussed, such as the growth of the cyclotron radius with decreasing magnetic field, which puts a ceiling on filter performance relative to fixed filter dimensions. Additionally, low pitch angle trajectories are dominated by motion parallel to the magnetic field lines and introduce non-adiabatic conditions and curvature drift. To minimize these effects and maximize electron acceptance into the filter, we present a three-potential-well design to simultaneously drain the parallel and transverse kinetic energies throughout the length of the filter. These optimizations are shown, in simulation, to achieve low-energy electron transport from a 1 T iron core (or 3 T superconducting) starting field with initial kinetic energy of 18.6 keV drained to <10 eV (<1 eV) in about 80 cm. This result for low field operation paves the way for the first demonstrator of the PTOLEMY spectrometer for measurement of electrons near the tritium endpoint to be constructed at the Gran Sasso National Laboratary (LNGS) in Italy.

physics.ins-det