SearcharxivSearch

arXiv subjects

A. Belousov

Publications and source records attributed to A. Belousov.

5 recordsLinked to original sources

Demonstrating CBM Capabilities by $Λ$ Baryon Reconstruction in Ni+Ni Collisions with the mCBM Experiment at SIS18 of GSI/FAIR

The Compressed Baryonic Matter (CBM) experiment at the upcoming Facility for Antiproton and Ion Research (FAIR) is a high-rate fixed-target experiment designed to investigate nuclear matter at extreme baryon densities in relativistic nucleus-nucleus collisions. To enable high-statistics measurements of rare probes, CBM is designed to operate at event rates up to 10 MHz. This necessitates the development of fast and radiation-tolerant detectors, self-triggered front-end electronics, a free-streaming data acquisition architecture, and real-time event reconstruction capabilities. Prototype versions and pre-series productions of the CBM detector systems have been deployed in the mini-CBM demonstrator setup mCBM - an experimental precursor comprising sub-components of all major CBM systems, installed at the SIS18 facility of GSI/FAIR within the FAIR Phase-0 program. In 2024, Ni+Ni collisions at a kinetic beam energy of 1.93 AGeV and an average interaction rate of about 250 kHz were successfully recorded. This dataset enables a detailed evaluation of the operational performance of the detector systems as well as the complete CBM data chain, while the reconstruction of rare $Λ$ baryons serves as a natural benchmark. This paper presents the first results on $Λ$ signal reconstruction with the mCBM experiment, demonstrating the readiness of the detector technologies and the data chain for the upcoming full-scale CBM experiment.

physics.ins-det

Measurement of lepton-jet correlation in deep-inelastic scattering with the H1 detector using machine learning for unfolding

The first measurement of lepton-jet momentum imbalance and azimuthal correlation in lepton-proton scattering at high momentum transfer is presented. These data, taken with the H1 detector at HERA, are corrected for detector effects using an unbinned machine learning algorithm OmniFold, which considers eight observables simultaneously in this first application. The unfolded cross sections are compared to calculations performed within the context of collinear or transverse-momentum-dependent (TMD) factorization in Quantum Chromodynamics (QCD) as well as Monte Carlo event generators. The measurement probes a wide range of QCD phenomena, including TMD parton distribution functions and their evolution with energy in so far unexplored kinematic regions.

hep-ex

Impact of jet-production data on the next-to-next-to-leading-order determination of HERAPDF2.0 parton distributions

The HERAPDF2.0 ensemble of parton distribution functions (PDFs) was introduced in 2015. The final stage is presented, a next-to-next-to-leading-order (NNLO) analysis of the HERA data on inclusive deep inelastic $ep$ scattering together with jet data as published by the H1 and ZEUS collaborations. A perturbative QCD fit, simultaneously of $α_s(M_Z^2)$ and and the PDFs, was performed with the result $α_s(M_Z^2) = 0.1156 \pm 0.0011~{\rm (exp)}~ ^{+0.0001}_{-0.0002}~ {\rm (model}$ ${\rm +~parameterisation)}~ \pm 0.0029~{\rm (scale)}$. The PDF sets of HERAPDF2.0Jets NNLO were determined with separate fits using two fixed values of $α_s(M_Z^2)$, $α_s(M_Z^2)=0.1155$ and $0.118$, since the latter value was already chosen for the published HERAPDF2.0 NNLO analysis based on HERA inclusive DIS data only. The different sets of PDFs are presented, evaluated and compared. The consistency of the PDFs determined with and without the jet data demonstrates the consistency of HERA inclusive and jet-production cross-section data. The inclusion of the jet data reduced the uncertainty on the gluon PDF. Predictions based on the PDFs of HERAPDF2.0Jets NNLO give an excellent description of the jet-production data used as input.

hep-ex

Determination of the strong coupling constant $α_s(M_Z)$ in next-to-next-to-leading order QCD using H1 jet cross section measurements

The strong coupling constant $α_s(M_Z)$ is determined from inclusive jet and dijet cross sections in neutral-current deep-inelastic $ep$ scattering (DIS) measured at HERA by the H1 collaboration using next-to-next-to-leading order (NNLO) QCD predictions. The dependence of the NNLO predictions and of the resulting value of $α_s(M_Z)$ at the $Z$-boson mass $m_Z$ are studied as a function of the choice of the renormalisation and factorisation scales. Using inclusive jet and dijet data together, the strong coupling constant is determined to be $α_s(M_Z)=0.1166\,(19)_{\rm exp}\,(24)_{\rm th}$. Complementary, $α_s(M_Z)$ is determined together with parton distribution functions of the proton (PDFs) from jet and inclusive DIS data measured by the H1 experiment. The value $α_s(M_Z)=0.1147\,(25)_{\rm tot}$ obtained is consistent with the determination from jet data alone. The impact of the jet data on the PDFs is studied. The running of the strong coupling is tested at different values of the renormalisation scale and the results are found to be in agreement with expectations.

hep-ex

High-precision measurements of krypton and xenon isotopes with a new static-mode Quadrupole Ion Trap Mass Spectrometer

Measuring the abundance and isotopic composition of noble gases in planetary atmospheres can answer fundamental questions in cosmochemistry and comparative planetology. However, noble gases are rare elements, a feature making their measurement challenging even on Earth. Furthermore, in space applications, power consumption, volume and mass constraints on spacecraft instrument accommodations require the development of compact innovative instruments able to meet the engineering requirements of the mission while still meeting the science requirements. Here we demonstrate the ability of the quadrupole ion trap mass spectrometer (QITMS) developed at the Jet Propulsion Laboratory (Caltech, Pasadena) to measure low quantities of heavy noble gases (Kr, Xe) in static operating mode and in the absence of a buffer gas such as helium. The sensitivity reaches 1E13 cps Torr-1 (about 1011 cps/Pa) of gas (Kr or Xe). The instrument is able to measure gas in static mode for extended periods of time (up to 48 h) enabling the acquisition of thousands of isotope ratios per measurement. Errors on isotope ratios follow predictions of the counting statistics and the instrument provides reproducible results over several days of measurements. For example, 1.7E-10 Torr (2.3E-8 Pa) of Kr measured continuously for 7 hours yielded a 0.6 permil precision on the 86Kr/84Kr ratio. Measurements of terrestrial and extraterrestrial samples reproduce values from the literature. A compact instrument based upon the QITMS design would have a sensitivity high enough to reach the precision on isotope ratios (e.g. better than 1 percent for 129,131-136Xe/130Xe ratios) necessary for a scientific payload measuring noble gases collected in the Venus atmosphere.

physics.ins-det