SearcharxivSearch

arXiv subjects

A. Bertolini

Publications and source records attributed to A. Bertolini.

At least 19 recordsLinked to original sources

Optimisation of TES design for the CRESST experiment

The CRESST experiment aims at the direct detection of sub-GeV dark matter particles via elastic scattering off nuclei in different target crystals at cryogenic temperatures. The advancement in W-TES sensors allowed the CRESST detectors to reach energy thresholds of 10 eV and lower, opening the way to the exploration of dark matter masses as low as 70 MeV/c2. This work presents optimisation studies of W-TESs aimed at further improving the signal-to-noise ratio and overall detector performance. In particular, we investigate the thickness, dimensions and material composition of phonon collectors and assess their impact on detector response. The results demonstrate a significant performance enhancement and establish new benchmarks for the sensors used within CRESST.

physics.ins-det

Advanced Virgo Plus for O5 -- Design Report Overview

This document presents an overview of the design, implementation, and expected performance of the Advanced Virgo Plus (AdV+) upgrades in view of the O5 observing run. Following the experience gained during the O4 commissioning and operations, the Virgo Collaboration has revised the upgrade strategy to address limitations associated with marginally stable recycling cavities. The O5 upgrade program combines elements from the original AdV+ Phase II project with new design solutions, including the implementation of stable recycling cavities, a major modification to the central interferometer layout, and a comprehensive renewal of critical subsystems. The planned upgrades are organized in two steps, targeting progressive improvements in operational stability, noise reduction, and detector sensitivity. Key developments include new vacuum infrastructures, suspensions, mirrors, optical configurations, quantum noise reduction systems, and high-power laser technologies. The resulting configuration is expected to significantly enhance the interferometer performance, enabling a substantial increase in astrophysical reach and scientific return during O5.

astro-ph.IM

ImpCresst -- A versatile simulation tool focusing on solid-state detectors at keV energies

We present ImpCresst, a Geant4-based Monte Carlo tool to simulate backgrounds from natural and cosmogenic radionuclides, and calibration signals in solid-state detectors and their response to it. It is tuned for a fast-evolving and heterogeneous detector environment with a focus on physics at the keV range. This tool was originally developed and validated by the CRESST collaboration; however, its flexibility and configurability make it suitable for other experiments with similar requirements. Key features of ImpCresst include the dynamic geometry implementation directly from CAD files, ROOT-based data persistency of the whole event topology and automatic metadata annotation for data provenance, and interfaces to various particle generators, particularly for radiogenic and cosmogenic radionuclides. It includes also a newly developed particle generator for radioactive bulk and surface contaminations which is completely independent of any user defined confinement volumes. The auxiliary tool CresstDS applies detector-specific energy and time resolution based on a user-provided data set of empirical parameterization. We discuss also how to manage an ImpCresst based workflow in an HPC environment based on Apptainer and nextflow.

physics.ins-det

Cryogenic geometric anti-spring vibration isolation system

The combination of low temperature and low vibration levels is key for ultrasensitive sensing applications such as scanning probe microscopy, large-mass quantum mechanics, and gravitational wave detection. Unfortunately, closed-cycle cryostats using pulse tube or GM coolers introduce strong low-frequency vibrations starting at 1 Hz. Mass-spring systems allow passive isolation, but for low-frequency applications the required spring constants and masses become impractical. Blade-based geometric anti-spring systems are compact isolators that operate from sub-Hz frequencies, but have not been demonstrated at cryogenic temperatures. Here, we characterize a geometric anti-spring system tuned to operate at cryogenic temperatures. Our cryogenic filter uses radially arranged titanium blade springs whose effective spring constant can be tuned in-situ using a magnetic actuator. Our system achieves a vertical resonance frequency of 185 mHz at 7K, which allows reduction of vibrations at the problematic 1 Hz cooler frequency by an order of magnitude.

physics.ins-det

Description of CRESST-II and CRESST-III pulse shape data

A set of data from 68 cryogenic detectors operated in the CRESST dark matter search experiment between 2013 and 2019 was collected and labeled to train binary classifiers for data cleaning. Here, we describe the data set and how the trained models can be applied to new data. The data and models are available online.

physics.ins-det

Description of CRESST-III lithium aluminate data

Two detector modules with lithium aluminate targets were operated in the CRESST underground setup between February and June 2021. The data collected in this period was used to set the currently strongest cross-section upper limits on the spin-dependent interaction of dark matter (DM) with protons and neutrons for the mass region between 0.25 and 1.5 GeV/c$^2$. The data are available online. In this document, we describe how the data set should be used to reproduce our dark matter results.

hep-ex

Observation of a low energy nuclear recoil peak in the neutron calibration data of an Al$_{2}$O$_{3}$ crystal in CRESST-III

The current generation of cryogenic solid state detectors used in direct dark matter and CE\textnu NS searches typically reach energy thresholds of $\mathcal{O}$(10)$\,$eV for nuclear recoils. For a reliable calibration in this energy regime a method has been proposed, providing mono-energetic nuclear recoils at low energies $\sim\,$100$\,$eV$\,$-$\,$1$\,$keV. In this work we report on the observation of a peak at (1113.6$^{+6.5}_{-6.5}$)$\,$eV in the data of an Al$_{2}$O$_{3}$ crystal in CRESST-III, which was irradiated with neutrons from an AmBe calibration source. We attribute this mono-energetic peak to the radiative capture of thermal neutrons on $^{27}$Al and the subsequent de-excitation via single $\gamma$-emission. We compare the measured results with the outcome of Geant4 simulations and investigate the possibility to make use of this effect for the energy calibration of Al$_{2}$O$_{3}$ detectors at low energies. We further investigate the possibility of a shift in the expected energy scale of this effect caused by the creation of defects in the target crystal.

physics.ins-det

The CRESST experiment: towards the next-generation of sub-GeV direct dark matter detection

Direct detection experiments have established the most stringent constraints on potential interactions between particle candidates for relic, thermal dark matter and Standard Model particles. To surpass current exclusion limits a new generation of experiments is being developed. The upcoming upgrade of the CRESST experiment will incorporate $\mathcal{O}$(100) detectors with different masses ranging from $\sim$2g to $\sim$24g, aiming to achieve unprecedented sensitivity to sub-GeV dark matter particles with a focus on spin-independent dark matter-nucleus scattering. This paper presents a comprehensive analysis of the planned upgrade, detailed experimental strategies, anticipated challenges, and projected sensitivities. Approaches to address and mitigate low-energy excess backgrounds $-$ a key limitation in previous and current sub-GeV dark matter searches $-$ are also discussed. In addition, a long-term roadmap for the next decade is outlined, including other potential scientific applications.

astro-ph.CO

First observation of single photons in a CRESST detector and new dark matter exclusion limits

The main goal of the CRESST-III experiment is the direct detection of dark matter particles via their scattering off target nuclei in cryogenic detectors. In this work we present the results of a Silicon-On-Sapphire (SOS) detector with a mass of 0.6$\,$g and an energy threshold of (6.7$\, \pm \,$0.2)$\,$eV with a baseline energy resolution of (1.0$\, \pm \,$0.2)$\,$eV. This allowed for a calibration via the detection of single luminescence photons in the eV-range, which could be observed in CRESST for the first time. We present new exclusion limits on the spin-independent and spin-dependent dark matter-nucleon cross section that extend to dark matter particle masses of less than 100$\,$MeV/c$^{2}$.

astro-ph.CO

Solar Neutrinos in Cryogenic Detectors

Coherent elastic neutrino-nucleus scattering (CE$\nu$NS) poses an irreducible background in the search for dark matter-nucleus elastic scatterings, which is commonly known as the neutrino floor. As direct dark matter search experiments keep improving their sensitivity into so far unexplored regions, they face the challenge of approaching this neutrino floor. A precise description of the CE$\nu$NS signal is therefore crucial for the description of backgrounds for future DM searches. In this work we discuss the scenario of detecting neutrinos in low-threshold, high-exposure cryogenic solid state experiments optimized for the search of low-mass dark matter. The energy range considered is completely dominated by solar neutrinos. In absence of any dark matter events, we treat solar neutrinos as the main signal of interest. We show that sensitivity to the flux of neutrinos from different production mechanisms can be achieved. In particular we investigate the sensitivity to the flux of pp and $^{7}$Be neutrinos, as well as CNO neutrinos. Furthermore, we investigate the sensitivity to dark matter signals in the presence of a solar neutrino background for different experimental scenarios, which are defined by three parameters: the target material, the energy threshold and the exposure. We show that experiments with thresholds of $\mathcal{O}$(eV) and exposures of $\mathcal{O}$(tonne-years), using CaWO$_{4}$ or Al$_{2}$O$_{3}$ targets, have discovery potential for dark matter interaction cross sections in the neutrino floor.

hep-ph

DoubleTES detectors to investigate the CRESST low energy background: results from above-ground prototypes

In recent times, the sensitivity of low-mass direct dark matter searches has been limited by unknown low energy backgrounds close to the energy threshold of the experiments known as the low energy excess (LEE). The CRESST experiment utilises advanced cryogenic detectors constructed with different types of crystals equipped with Transition Edge Sensors (TESs) to measure signals of nuclear recoils induced by the scattering of dark matter particles in the detector. In CRESST, this low energy background manifests itself as a steeply rising population of events below 200 eV. A novel detector design named doubleTES using two identical TESs on the target crystal was studied to investigate the hypothesis that the events are sensor-related. We present the first results from two such modules, demonstrating their ability to differentiate between events originating from the crystal's bulk and those occurring in the sensor or in its close proximity.

physics.ins-det

A likelihood framework for cryogenic scintillating calorimeters used in the CRESST dark matter search

Cryogenic scintillating calorimeters are ultrasensitive particle detectors for rare event searches, particularly for the search for dark matter and the measurement of neutrino properties. These detectors are made from scintillating target crystals generating two signals for each particle interaction. The phonon (heat) signal precisely measures the deposited energy independent of the type of interacting particle. The scintillation light signal yields particle discrimination on an event-by-event basis. This paper presents a likelihood framework modeling backgrounds and a potential dark matter signal in the two-dimensional plane spanned by phonon and scintillation light energies. We apply the framework to data from CaWO$_4$-based detectors operated in the CRESST dark matter search. For the first time, a single likelihood framework is used in CRESST to model the data and extract results on dark matter in one step by using a profile likelihood ratio test. Our framework simultaneously fits (neutron) calibration data and physics (background) data and allows combining data from multiple detectors. Although tailored to CaWO$_4$-targets and the CRESST experiment, the framework can easily be expanded to other materials and experiments using scintillating cryogenic calorimeters for dark matter search and neutrino physics.

astro-ph.CO

Optimal operation of cryogenic calorimeters through deep reinforcement learning

Cryogenic phonon detectors with transition-edge sensors achieve the best sensitivity to light dark matter-nucleus scattering in current direct detection dark matter searches. In such devices, the temperature of the thermometer and the bias current in its readout circuit need careful optimization to achieve optimal detector performance. This task is not trivial and is typically done manually by an expert. In our work, we automated the procedure with reinforcement learning in two settings. First, we trained on a simulation of the response of three CRESST detectors used as a virtual reinforcement learning environment. Second, we trained live on the same detectors operated in the CRESST underground setup. In both cases, we were able to optimize a standard detector as fast and with comparable results as human experts. Our method enables the tuning of large-scale cryogenic detector setups with minimal manual interventions.

physics.ins-det

Detector development for the CRESST experiment

Recently low-mass dark matter direct searches have been hindered by a low energy background, drastically reducing the physics reach of the experiments. In the CRESST-III experiment, this signal is characterised by a significant increase of events below 200 eV. As the origin of this background is still unknown, it became necessary to develop new detector designs to reach a better understanding of the observations. Within the CRESST collaboration, three new different detector layouts have been developed and they are presented in this contribution.

physics.ins-det

Light Dark Matter Search Using a Diamond Cryogenic Detector

Diamond operated as a cryogenic calorimeter is an excellent target for direct detection of low-mass dark matter candidates. Following the realization of the first low-threshold cryogenic detector that uses diamond as absorber for astroparticle physics applications, we now present the resulting exclusion limits on the elastic spin-independent interaction cross-section of dark matter with diamond. We measured two 0.175 g CVD (Chemical Vapor Deposition) diamond samples, each instrumented with a W-TES. Thanks to the energy threshold of just 16.8 eV of one of the two detectors, we set exclusion limits on the elastic spin-independent interaction of dark matter particles with carbon nuclei down to dark matter masses as low as 0.122 GeV/c2. This work shows the scientific potential of cryogenic detectors made from diamond and lays the foundation for the use of this material as target for direct detection dark matter experiments.

astro-ph.CO

High-Dimensional Bayesian Likelihood Normalisation for CRESST's Background Model

Using CaWO$_4$ crystals as cryogenic calorimeters, the CRESST experiment searches for nuclear recoils caused by the scattering of potential Dark Matter particles. A reliable identification of a potential signal crucially depends on an accurate background model. In this work we introduce an improved normalisation method for CRESST's model of the electromagnetic backgrounds. Spectral templates, based on Geant4 simulations, are normalised via a Bayesian likelihood fit to experimental background data. Contrary to our previous work, no assumption of partial secular equilibrium is required, which results in a more robust and versatile applicability. Furthermore, considering the correlation between all background components allows us to explain 82.7% of the experimental background within [1 keV, 40 keV], an improvement of 18.6% compared to our previous method.

physics.ins-det

Observation of a low energy nuclear recoil peak in the neutron calibration data of the CRESST-III Experiment

New-generation direct searches for low mass dark matter feature detection thresholds at energies well below 100 eV, much lower than the energies of commonly used X-ray calibration sources. This requires new calibration sources with sub-keV energies. When searching for nuclear recoil signals, the calibration source should ideally cause mono-energetic nuclear recoils in the relevant energy range. Recently, a new calibration method based on the radiative neutron capture on $^{182}$W with subsequent de-excitation via single $\gamma$-emission leading to a nuclear recoil peak at 112 eV was proposed. The CRESST-III dark matter search operated several CaWO$_{4}$-based detector modules with detection thresholds below 100 eV in the past years. We report the observation of a peak around the expected energy of 112 eV in the data of three different detector modules recorded while irradiated with neutrons from different AmBe calibration sources. We compare the properties of the observed peaks with Geant-4 simulations and assess the prospects of using this for the energy calibration of CRESST-III detectors.

physics.ins-det

Results on sub-GeV Dark Matter from a 10 eV Threshold CRESST-III Silicon Detector

We present limits on the spin-independent interaction cross section of dark matter particles with silicon nuclei, derived from data taken with a cryogenic calorimeter with 0.35 g target mass operated in the CRESST-III experiment. A baseline nuclear recoil energy resolution of $(1.36\pm 0.05)$ eV$_{\text{nr}}$, currently the lowest reported for macroscopic particle detectors, and a corresponding energy threshold of $(10.0\pm 0.2)$ eV$_{\text{nr}}$ have been achieved, improving the sensitivity to light dark matter particles with masses below 160 MeV/c$^2$ by a factor of up to 20 compared to previous results. We characterize the observed low energy excess, and we exclude noise triggers and radioactive contaminations on the crystal surfaces as dominant contributions.

astro-ph.CO