SearcharxivSearch

arXiv subjects

A. Bonenfant

Publications and source records attributed to A. Bonenfant.

6 recordsLinked to original sources

ePIC Early Science Report

This Early Science Report from the ePIC Collaboration outlines the compelling physics program achievable during the first years of operation of the Electron-Ion Collider (EIC), prior to the establishment of the full design luminosity and energy range. The analyses are based on realistic early-running beam configurations and detailed Geant4 ePIC detector simulations, hit digitization and data reconstruction. The projected studies from the physics working groups of ePIC span inclusive, semi-inclusive, exclusive, diffractive and tagging, as well as jet and heavy flavor measurements in both electron-proton and electron-ion collisions. Even before the collider reaches its full design performance, these measurements will constrain parton distribution functions in nucleons and nuclei, access transverse-momentum-dependent and spin-dependent observables, probe gluon dynamics in nuclei, and initiate a program of imaging of quarks and gluons. Each measurement is directly connected to the core science pillars of the EIC, identified in the 2018 report by the National Academy of Sciences: understanding the origin of the nucleon mass, unraveling the spin structure of the nucleon, and exploring the emergent properties of dense gluonic matter. The results presented here provide examples that demonstrate that the early years of EIC running with ePIC will deliver novel world-leading insights into Quantum Chromodynamics. In addition, the early science program will establish measurement and analysis methodologies that will pave the way to the subsequent full EIC physics program.

nucl-ex

Measurement of dijet transverse momentum imbalance and azimuthal acoplanarity in $p$+$p$ collisions at $\sqrt{s} = 200$ GeV with the sPHENIX detector

This Letter reports on measurements of dijet transverse momentum ($p_\mathrm{T}$) imbalance and azimuthal acoplanarity in proton-proton collisions at $\sqrt{s} = 200$~GeV, using data recorded by the sPHENIX detector at the Relativistic Heavy Ion Collider corresponding to an integrated luminosity of $41$~pb$^{-1}$. Jets are reconstructed using the anti-$k_t$ algorithm with radius parameters $R = 0.3$ to $0.8$ from electromagnetic and hadronic calorimeter energy deposits. The jet $p_\mathrm{T}$ resolution is determined directly in data using two independent methods. The dijet $p_\mathrm{T}$ imbalance is characterized by the ratio $x_\mathrm{J} = p_\mathrm{T,2}/p_\mathrm{T,1}$ where $p_\mathrm{T,1(2)}$ is the highest (second-highest) jet $p_\mathrm{T}$ in the event. The dijet azimuthal acoplanarity $Δϕ= |ϕ_1 - ϕ_2|$ is also reported. Results are reported for different $p_\mathrm{T,1}$ selections and jet radius parameters, normalized per dijet pair, and compared to the results of \textsc{Pythia} and \textsc{Herwig} Monte Carlo event generators. These measurements provide a stringent quantitative test of the modeling of QCD parton shower and hadronization dynamics, place important constraints on event-generator descriptions at RHIC energies, and establish a comprehensive proton-proton baseline for forthcoming measurements of jet modification in heavy ion collisions.

nucl-ex

Design and Performance of a 96-channel Resistive PICOSEC Micromegas Detector for ENUBET

The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector that achieves picosecond-level timing by coupling a Cherenkov radiator, typically an MgF2 crystal, to a Micromegas-based photodetector with a photocathode. This configuration allows the fast photoelectron-induced signal to suppress the intrinsic time jitter of gaseous detectors, enabling sub-20 ps timing precision while preserving the robustness and scalability of micro-pattern gaseous detector technologies. The 96-pad PICOSEC-MM detector is a large-area demonstrator optimized for precision timing in high-energy physics, building on research and development insights from earlier 7-pad resistive prototypes to validate scalability, uniformity, and robustness for the ENUBET project. It employs a 2.5 nm diamond-like carbon photocathode and a Micromegas board with a surface resistivity of 10 megaohms per square, and was characterized using 150 GeV/c muons at the CERN SPS beamline, with one-third of the active area instrumented per run. A dedicated alignment procedure for multi-pad PICOSEC-MM systems was used to reconstruct pad centers and merge measurements across regions, yielding a timing resolution of 43 ps and uniform signal arrival time distributions over the tested area. Mechanical flatness was identified as a key factor, with planarity tolerances within 10 micrometers required to maintain good timing resolution, and the successful operation of the 96-pad demonstrator confirms the scalability of the PICOSEC-MM concept toward robust, high-granularity, picosecond-level gaseous timing detectors for monitored neutrino beam experiments such as ENUBET.

physics.ins-det

Measurement of charged hadron multiplicity in Au+Au collisions at $\sqrt{\text{s}_{\text{NN}}} = 200$ GeV with the sPHENIX detector

The pseudorapidity distribution of charged hadrons produced in Au+Au collisions at a center-of-mass energy of $\sqrt{s_\mathrm{NN}} = 200$ GeV is measured using data collected by the sPHENIX detector. Charged hadron yields are extracted by counting cluster pairs in the inner and outer layers of the Intermediate Silicon Tracker, with corrections applied for detector acceptance, reconstruction efficiency, combinatorial pairs, and contributions from secondary decays. The measured distributions cover $|η| < 1.1$ across various centralities, and the average pseudorapidity density of charged hadrons at mid-rapidity is compared to predictions from Monte Carlo heavy-ion event generators. This result, featuring full azimuthal coverage at mid-rapidity, is consistent with previous experimental measurements at the Relativistic Heavy Ion Collider, thereby supporting the broader sPHENIX physics program.

nucl-ex

Measurement of the transverse energy density in Au+Au collisions at $\sqrt{s_{NN}} = 200$ GeV with the sPHENIX detector

This paper reports measurements of the transverse energy per unit pseudorapidity ($dE_{T}/dη$) produced in Au+Au collisions at $\sqrt{s_{NN}} = 200$ GeV, performed with the sPHENIX detector at the Relativistic Heavy Ion Collider (RHIC). The results cover the pseudorapidity range $\left|η\right| < 1.1$ and constitute the first such measurement performed using a hadronic calorimeter at RHIC. Measurements of $dE_{T}/dη$ are presented for a range of centrality intervals and the average $dE_{T}/dη$ as a function of the number of participating nucleons, $N_{\mathrm{part}}$, is compared to a variety of Monte Carlo heavy-ion event generators. The results are in agreement with previous measurements at RHIC, and feature an improved granularity in $η$ and improved precision in low-$N_{\mathrm{part}}$ events.

nucl-ex

The sPHENIX Micromegas Outer Tracker

The sPHENIX Time Projection Chamber Outer Tracker (TPOT) is a Micromegas based detector. It is a part of the sPHENIX experiment that aims to facilitate the calibration of the Time Projection Chamber, in particular the correction of the time-averaged and beam-induced distortions of the electron drift. This paper describes the detector mission, setup, construction, installation, commissioning and performance during the first year of sPHENIX data taking.

physics.ins-det