Searcharxiv⌕ Search

arXiv subjects

A. Bonhomme

Publications and source records attributed to A. Bonhomme.

28 records · Page 2Linked to original sources

First antineutrino energy spectrum from $^{235}$U fissions with the STEREO detector at ILL

This article reports the measurement of the $^{235}$U-induced antineutrino spectrum shape by the STEREO experiment. 43'000 antineutrinos have been detected at about 10 m from the highly enriched core of the ILL reactor during 118 full days equivalent at nominal power. The measured inverse beta decay spectrum is unfolded to provide a pure $^{235}$U spectrum in antineutrino energy. A careful study of the unfolding procedure, including a cross-validation by an independent framework, has shown that no major biases are introduced by the method. A significant local distortion is found with respect to predictions around $E_ν\simeq 5.3$ MeV. A gaussian fit of this local excess leads to an amplitude of $A = 12.1 \pm 3.4\%$ (3.5$σ$).

hep-ex↗

Large-size sub-keV sensitive germanium detectors for the CONUS experiment

Intense fluxes of reactor antineutrinos offer a unique possibility to probe the fully coherent character of elastic neutrino scattering off atomic nuclei. In this regard, detectors face the challenge to register tiny recoil energies of a few keV at the maximum. The CONUS experiment was installed in 17.1 m distance from the reactor core of the nuclear power plant in Brokdorf, Germany, and was designed to detect this neutrino interaction channel by using four 1 kg-sized point contact germanium detectors with sub-keV energy thresholds. This report describes the unique specifications addressed to the design, the research and development, and the final production of these detectors. It demonstrates their excellent electronic performance obtained during commissioning under laboratory conditions as well as during the first two years of operation at the reactor site which started on April 1, 2018. It highlights the long-term stability of different detector parameters and the achieved background levels of the germanium detectors inside the CONUS shield setup.

physics.ins-det↗

Constraints on elastic neutrino nucleus scattering in the fully coherent regime from the CONUS experiment

We report the best limit on coherent elastic scattering of electron antineutrinos emitted from a nuclear reactor off germanium nuclei. The measurement was performed with the CONUS detectors positioned at 17.1m from the 3.9GWth reactor core of the nuclear power plant in Brokdorf, Germany. The antineutrino energies of less than 10 MeV assure interactions in the fully coherent regime. The analyzed dataset includes 248.7 kgd with the reactor turned on and background data of 58.8 kgd with the reactor off. With a quenching parameter of k = 0.18 for germanium, we determined an upper limit on the number of neutrino events of 85 in the region of interest at 90% confidence level. This new CONUS dataset disfavors quenching parameters above k = 0.27, under the assumption of standard-model-like coherent scattering of the reactor antineutrinos.

hep-ex↗

Accurate Measurement of the Electron Antineutrino Yield of U-235 Fissions from the STEREO Experiment with 119 Days of Reactor-On Data

We report a measurement of the antineutrino rate from the fission of U-235 with the STEREO detector using 119 days of reactor turned on. In our analysis, we perform several detailed corrections and achieve the most precise single measurement at reactors with highly enriched U-235 fuel. We measure an IBD cross section per fission of $σ_f$ = (6.34 $\pm$ 0.06 [stat] $\pm$ 0.15 [sys] $\pm$ 0.15 [model]) $\times$ 10${}^{-43}$ cm${}^{2}$/fission and observe a rate deficit of (5.2 $\pm$ 0.8 [stat] $\pm$ 2.3 [sys] $\pm$ 2.3 [model])% compared to the model, consistent with the deficit of the world average. Testing U-235 as the sole source of the deficit, we find a tension between the results of lowly and highly enriched U-235 fuel of 2.1 standard deviations.

hep-ex↗

Improved Sterile Neutrino Constraints from the STEREO Experiment with 179 Days of Reactor-On Data

The STEREO experiment is a very short baseline reactor antineutrino experiment. It is designed to test the hypothesis of light sterile neutrinos being the cause of a deficit of the observed antineutrino interaction rate at short baselines with respect to the predicted rate, known as the reactor antineutrino anomaly. The STEREO experiment measures the antineutrino energy spectrum in six identical detector cells covering baselines between 9 and 11 m from the compact core of the ILL research reactor. In this article, results from 179 days of reactor turned on and 235 days of reactor turned off are reported at a high degree of detail. The current results include improvements in the modelling of detector optical properties and the gamma-cascade after neutron captures by gadolinium, the treatment of backgrounds, and the statistical method of the oscillation analysis. Using a direct comparison between antineutrino spectra of all cells, largely independent of any flux prediction, we find the data compatible with the null oscillation hypothesis. The best-fit point of the reactor antineutrino anomaly is rejected at more than 99.9% C.L.

hep-ex↗

Note on arXiv:2005.05301, 'Preparation of the Neutrino-4 experiment on search for sterile neutrino and the obtained results of measurements'

We comment on the claimed observation [arXiv:arXiv:2005.05301] of sterile neutrino oscillations by the Neutrino-4 collaboration. Such a claim, which requires the existence of a new fundamental particle, demands a level of rigor commensurate with its impact. The burden lies with the Neutrino-4 collaboration to provide the information necessary to prove the validity of their claim to the community. In this note, we describe aspects of both the data and analysis method that might lead to an oscillation signature arising from a null experiment and describe additional information needed from the Neutrino-4 collaboration to support the oscillation claim. Additionally, as opposed to the assertion made by the Neutrino-4 collaboration, we also show that the method of 'coherent summation' using the $L/E$ parameter produces similar results to the methods used by the PROSPECT and the STEREO collaborations.

hep-ex↗

Improved STEREO simulation with a new gamma ray spectrum of excited gadolinium isotopes using FIFRELIN

The STEREO experiment measures the electron antineutrino spectrum emitted in a research reactor using the inverse beta decay reaction on H nuclei in a gadolinium loaded liquid scintillator. The detection is based on a signal coincidence of a prompt positron and a delayed neutron capture event. The simulated response of the neutron capture on gadolinium is crucial for the comparison with data, in particular in the case of the detection efficiency. Among all stable isotopes, $^{155}$Gd and $^{157}$Gd have the highest cross sections for thermal neutron capture. The excited nuclei after the neutron capture emit gamma rays with a total energy of about 8 MeV. The complex level schemes of $^{156}$Gd and $^{158}$Gd are a challenge for the modeling and prediction of the deexcitation spectrum, especially for compact detectors where gamma rays can escape the active volume. With a new description of the Gd(n,$γ$) cascades obtained using the FIFRELIN code, the agreement between simulation and measurements with a neutron calibration source was significantly improved in the STEREO experiment. A database of ten millions of deexcitation cascades for each isotope has been generated and is now available for the user.

physics.ins-det↗

Sterile Neutrino Constraints from the STEREO Experiment with 66 days of Reactor-on Data

The reactor antineutrino anomaly might be explained by the oscillation of reactor antineutrinos toward a sterile neutrino of eV mass. In order to explore this hypothesis, the STEREO experiment measures the antineutrino energy spectrum in six different detector cells covering baselines between 9 and 11 m from the compact core of the ILL research reactor. In this Letter, results from 66 days of reactor turned on and 138 days of reactor turned off are reported. A novel method to extract the antineutrino rates has been developed based on the distribution of the pulse shape discrimination parameter. The test of a new oscillation toward a sterile neutrino is performed by comparing ratios of cells, independent of absolute normalization and of the prediction of the reactor spectrum. The results are found to be compatible with the null oscillation hypothesis and the best fit of the reactor antineutrino anomaly is excluded at 97.5\% C.L.

hep-ex↗

The STEREO Experiment

The STEREO experiment is a very short baseline reactor antineutrino experiment aiming at testing the hypothesis of light sterile neutrinos as an explanation of the deficit of the observed neutrino interaction rate with respect to the predicted rate, known as the Reactor Antineutrino Anomaly. The detector center is located 10 m away from the compact, highly $^{235}$U enriched core of the research nuclear reactor of the Institut Laue Langevin in Grenoble, France. This paper describes the STEREO site, the detector components and associated shielding designed to suppress the external sources of background which were characterized on site. It reports the performances in terms of detector response and energy reconstruction.

physics.ins-det↗

Self-assembly of carbon-nanotube-based single electron memories

We demonstrate wafer-scale integration of single electron memories based on carbon nanotube field effect transistors (cnfets) by a complete self assembly process. First, a dry self assembly based on a Hot Filament assisted Chemical Vapor Deposition technique allows both localized growth and in situ electrical connection of carbon nanotubes on predefined catalytic electrodes. The semiconducting carbon nanotubes integration yield can exceed 50% for a batch. Secondly, a wet self-assembly attaches single 30 nm-diameter gold bead in the nanotube vicinity via chemical functionalization. The bead acts as the memory storage node while the cnfet operated in the subthreshold regime is an electrometer having exponential gain. Below 50 K, the transfer characteristics of some functionalized cnfets show highly reproducible hysteretical steps whose height can reach one decade of current. Evaluation of the capacitance confirms these current steps originate from single electron transfers between the bead and the nanotubes with a time retention exceeding 550s at 1.5K.

cond-mat.mes-hall↗