Searcharxiv⌕ Search

arXiv subjects

A. Brown

Publications and source records attributed to A. Brown.

At least 109 records · Page 6Linked to original sources

The $^{7}$Be($\boldsymbol{n,p}$)$^{7}$Li reaction and the Cosmological Lithium Problem: measurement of the cross section in a wide energy range at n_TOF (CERN)

We report on the measurement of the $^{7}$Be($n, p$)$^{7}$Li cross section from thermal to approximately 325 keV neutron energy, performed in the high-flux experimental area (EAR2) of the n\_TOF facility at CERN. This reaction plays a key role in the lithium yield of the Big Bang Nucleosynthesis (BBN) for standard cosmology. The only two previous time-of-flight measurements performed on this reaction did not cover the energy window of interest for BBN, and showed a large discrepancy between each other. The measurement was performed with a Si-telescope, and a high-purity sample produced by implantation of a $^{7}$Be ion beam at the ISOLDE facility at CERN. While a significantly higher cross section is found at low-energy, relative to current evaluations, in the region of BBN interest the present results are consistent with the values inferred from the time-reversal $^{7}$Li($p, n$)$^{7}$Be reaction, thus yielding only a relatively minor improvement on the so-called Cosmological Lithium Problem (CLiP). The relevance of these results on the near-threshold neutron production in the p+$^{7}$Li reaction is also discussed.

nucl-ex↗

Cross section measurements of $^{155,157}$Gd(n,$γ$) induced by thermal and epithermal neutrons

Neutron capture measurements on $^{155}$Gd and $^{157}$Gd were performed using the time-of-flight technique at the n\_TOF facility at CERN. Four samples in form of self-sustaining metallic discs isotopically enriched in $^{155}$Gd and $^{157}$Gd were used. The measurements were carried out at the experimental area (EAR1) at 185 m from the neutron source, with an array of 4 C$_6$D$_6$ liquid scintillation detectors. The capture cross sections of $^{155}$Gd and $^{157}$Gd at neutron kinetic energy of 0.0253 eV have been estimated to be 62.2(2.2) kb and 239.8(9.3) kb, respectively, thus up to 6\% different relative to the ones reported in the nuclear data libraries. A resonance shape analysis has been performed in the resolved resonance region up to 180 eV and 300 eV, respectively, in average resonance parameters have been found in good agreement with evaluations. Above these energies the observed resonance-like structures in the cross section have been tentatively characterised in terms of resonance energy and area up to 1 keV.

nucl-ex↗

COHERENT Collaboration data release from the first observation of coherent elastic neutrino-nucleus scattering

This release includes data and information necessary to perform independent analyses of the COHERENT result presented in Akimov et al., arXiv:1708.01294 [nucl-ex]. Data is shared in a binned, text-based format, including both "signal" and "background" regions, so that counts and associated uncertainties can be quantitatively calculated for the purpose of separate analyses. This document describes the included information and its format, offering some guidance on use of the data. Accompanying code examples show basic interaction with the data using Python.

nucl-ex↗

A Precision Experiment to Investigate Long-Lived Radioactive Decays

Radioactivity is understood to be described by a Poisson process, yet some measurements of nuclear decays appear to exhibit unexpected variations. Generally, the isotopes reporting these variations have long half lives, which are plagued by large measurement uncertainties. In addition to these inherent problems, there are some reports of time-dependent decay rates and even claims of exotic neutrino-induced variations. We present a dedicated experiment for the stable long-term measurement of gamma emissions resulting from $β$ decays, which will provide high-quality data and allow for the identification of potential systematic influences. Radioactive isotopes are monitored redundantly by thirty-two 76 mm $\times$ 76 mm NaI(Tl) detectors in four separate temperature-controlled setups across three continents. In each setup, the monitoring of environmental and operational conditions facilitates correlation studies. The deadtime-free performance of the data acquisition system is monitored by LED pulsers. Digitized photomultiplier waveforms of all events are recorded individually, enabling a study of time-dependent effects spanning microseconds to years, using both time-binned and unbinned analyses. We characterize the experiment's stability and show that the relevant systematics are accounted for, enabling precise measurements of effects at levels well below $\mathcal{O}(10^{-4})$.

nucl-ex↗

COHERENT 2018 at the Spallation Neutron Source

The primary goal of the COHERENT collaboration is to measure and study coherent elastic neutrino-nucleus scattering (CEvNS) using the high-power, few-tens-of-MeV, pulsed source of neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The COHERENT collaboration reported the first detection of CEvNS [Akimov:2017ade] using a CsI[Na] detector. At present the collaboration is deploying four detector technologies: a CsI[Na] scintillating crystal, p-type point-contact germanium detectors, single-phase liquid argon, and NaI[Tl] crystals. All detectors are located in the neutron-quiet basement of the SNS target building at distances 20-30 m from the SNS neutrino source. The simultaneous measurement in all four COHERENT detector subsystems will test the $N^2$ dependence of the cross section and search for new physics. In addition, COHERENT is measuring neutrino-induced neutrons from charged- and neutral-current neutrino interactions on nuclei in shielding materials, which represent a non-negligible background for CEvNS as well as being of intrinsic interest. The Collaboration is planning as well to look for charged-current interactions of relevance to supernova and weak-interaction physics. This document describes concisely the COHERENT physics motivations, sensitivity, and next plans for measurements at the SNS to be accomplished on a few-year timescale.

physics.ins-det↗

Intrinsic backgrounds from Rn and Kr in the XENON100 experiment

In this paper, we describe the XENON100 data analyses used to assess the target-intrinsic background sources radon ($^{222}$Rn), thoron ($^{220}$Rn) and krypton ($^{85}$Kr). We detail the event selections of high-energy alpha particles and decay-specific delayed coincidences. We derive distributions of the individual radionuclides inside the detector and quantify their abundances during the main three science runs of the experiment over a period of $\sim$ 4 years, from January 2010 to January 2014. We compare our results to external measurements of radon emanation and krypton concentrations where we find good agreement. We report an observed reduction in concentrations of radon daughters that we attribute to the plating-out of charged ions on the negatively biased cathode.

astro-ph.IM↗

Signal Yields of keV Electronic Recoils and Their Discrimination from Nuclear Recoils in Liquid Xenon

We report on the response of liquid xenon to low energy electronic recoils below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method based on Markov Chain Monte Carlo is used to extract the photon yields and recombination fluctuations from the experimental data. The photon yields measured at the two lower fields are in agreement with those from literature; additional measurements at a higher field of 366 V/cm are presented. The electronic and nuclear recoil discrimination as well as its dependence on the drift field and photon detection efficiency are investigated at these low energies. The results provide new measurements in the energy region of interest for dark matter searches using liquid xenon.

astro-ph.IM↗

First Dark Matter Search Results from the XENON1T Experiment

We report the first dark matter search results from XENON1T, a $\sim$2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first ton-scale detector of this kind. The blinded search used 34.2 live days of data acquired between November 2016 and January 2017. Inside the (1042$\pm$12) kg fiducial mass and in the [5, 40] $\mathrm{keV}_{\mathrm{nr}}$ energy range of interest for WIMP dark matter searches, the electronic recoil background was $(1.93 \pm 0.25) \times 10^{-4}$ events/(kg $\times$ day $\times \mathrm{keV}_{\mathrm{ee}}$), the lowest ever achieved in a dark matter detector. A profile likelihood analysis shows that the data is consistent with the background-only hypothesis. We derive the most stringent exclusion limits on the spin-independent WIMP-nucleon interaction cross section for WIMP masses above 10 GeV/c${}^2$, with a minimum of 7.7 $\times 10^{-47}$ cm${}^2$ for 35-GeV/c${}^2$ WIMPs at 90% confidence level.

astro-ph.CO↗

Search for magnetic inelastic dark matter with XENON100

We present the first search for dark matter-induced delayed coincidence signals in a dual-phase xenon time projection chamber, using the 224.6 live days of the XENON100 science run II. This very distinct signature is predicted in the framework of magnetic inelastic dark matter which has been proposed to reconcile the modulation signal reported by the DAMA/LIBRA collaboration with the null results from other direct detection experiments. No candidate event has been found in the region of interest and upper limits on the WIMP's magnetic dipole moment are derived. The scenarios proposed to explain the DAMA/LIBRA modulation signal by magnetic inelastic dark matter interactions of WIMPs with masses of 58.0 GeV/c$^2$ and 122.7 GeV/c$^2$ are excluded at 3.3 $σ$ and 9.3 $σ$, respectively.

astro-ph.CO↗

Search for Bosonic Super-WIMP Interactions with the XENON100 Experiment

We present results of searches for vector and pseudo-scalar bosonic super-WIMPs, which are dark matter candidates with masses at the keV-scale, with the XENON100 experiment. XENON100 is a dual-phase xenon time projection chamber operated at the Laboratori Nazionali del Gran Sasso. A profile likelihood analysis of data with an exposure of 224.6 live days $\times$ 34\,kg showed no evidence for a signal above the expected background. We thus obtain new and stringent upper limits in the $(8-125)$\,keV/c$^2$ mass range, excluding couplings to electrons with coupling constants of $g_{ae} > 3\times10^{-13}$ for pseudo-scalar and $α'/α> 2\times10^{-28}$ for vector super-WIMPs, respectively. These limits are derived under the assumption that super-WIMPs constitute all of the dark matter in our galaxy.

astro-ph.CO↗

The XENON1T Dark Matter Experiment

The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute the active target of the dual-phase time projection chamber. The scintillation and ionization signals from particle interactions are detected with low-background photomultipliers. This article describes the XENON1T instrument and its subsystems as well as strategies to achieve an unprecedented low background level. First results on the detector response and the performance of the subsystems are also presented.

astro-ph.IM↗

Experimental setup and procedure for the measurement of the 7Be(n,p)7Li reaction at n_TOF

Following the completion of the second neutron beam line and the related experimental area (EAR2) at the n_TOF spallation neutron source at CERN, several experiments were planned and performed. The high instantaneous neutron flux available in EAR2 allows to investigate neutron indiced reactions with charged particles in the exit channel even employing targets made out of small amounts of short-lived radioactive isotopes. After the successful measurement of the 7Be(n,α)α cross section, the 7Be(n,p)7Li reaction was studied in order to provide still missing cross section data of relevance for Big Bang Nucleosynthesis (BBN), in an attempt to find a solution to the cosmological Lithium abundance problem. This paper describes the experimental setup employed in such a measurement and its characterization.

physics.ins-det↗

Observation of Coherent Elastic Neutrino-Nucleus Scattering

The coherent elastic scattering of neutrinos off nuclei has eluded detection for four decades, even though its predicted cross-section is the largest by far of all low-energy neutrino couplings. This mode of interaction provides new opportunities to study neutrino properties, and leads to a miniaturization of detector size, with potential technological applications. We observe this process at a 6.7-sigma confidence level, using a low-background, 14.6-kg CsI[Na] scintillator exposed to the neutrino emissions from the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. Characteristic signatures in energy and time, predicted by the Standard Model for this process, are observed in high signal-to-background conditions. Improved constraints on non-standard neutrino interactions with quarks are derived from this initial dataset.

nucl-ex↗

An Updated 2017 Astrometric Solution for Betelgeuse

We provide an update for the astrometric solution for the Type II supernova progenitor Betelgeuse using the revised Hipparcos Intermediate Astrometric Data (HIAD) of van Leeuwen, combined with existing VLA and new e-MERLIN and ALMA positions. The 2007 Hipparcos refined abscissa measurements required the addition of so-called Cosmic Noise of 2.4 mas to find an acceptable 5-parameter stochastic solution. We find that a measure of radio Cosmic Noise should also be included for the radio positions because surface inhomogeneities exist at a level significant enough to introduce additional intensity centroid uncertainty. Combining the 2007 HIAD with the proper motions based solely on the radio positions leads to a parallax of $π= 5.27\pm 0.78$ mas ($190^{+33}_{-25}$ pc), smaller than the Hipparcos 2007 value of $6.56\pm 0.83$ mas ($152^{+22}_{-17}$ pc; van Leeuwen 2007). Furthermore, combining the VLA and new e-MERLIN and ALMA radio positions with the 2007 HIAD, and including radio Cosmic Noise of 2.4 mas, leads to a nominal parallax solution of $4.51 \pm 0.80$ mas ($222^{+48}_{-34}$ pc), which while only $0.7σ$ different from the 2008 solution of Harper et al. it is $2.6σ$ different from the solution of van Leeuwen. An accurate and precise parallax for Betelgeuse is always going to be difficult to obtain because it is small compared to the stellar angular diameter ($θ=44$ mas). We outline an observing strategy, utilizing future mm and sub-mm high-spatial resolution interferometry that must be used if substantial improvements in precision and accuracy of the parallax and distance are to be achieved.

astro-ph.SR↗

Online $^{222}$Rn removal by cryogenic distillation in the XENON100 experiment

We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column is integrated into the gas purification loop of the XENON100 detector for online radon removal. This enabled us to significantly reduce the constant $^{222}$Rn background originating from radon emanation. After inserting an auxiliary $^{222}$Rn emanation source in the gas loop, we determined a radon reduction factor of R > 27 (95% C.L.) for the distillation column by monitoring the $^{222}$Rn activity concentration inside the XENON100 detector.

physics.ins-det↗

Removing krypton from xenon by cryogenic distillation to the ppq level

The XENON1T experiment aims for the direct detection of dark matter in a cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the $β$-emitter $^{85}$Kr which is an intrinsic contamination of the xenon. For the XENON1T experiment a concentration of natural krypton in xenon $\rm{^{nat}}$Kr/Xe < 200 ppq (parts per quadrillion, 1 ppq = 10$^{-15}$ mol/mol) is required. In this work, the design of a novel cryogenic distillation column using the common McCabe-Thiele approach is described. The system demonstrated a krypton reduction factor of 6.4$\cdot$10$^5$ with thermodynamic stability at process speeds above 3 kg/h. The resulting concentration of $\rm{^{nat}}$Kr/Xe < 26 ppq is the lowest ever achieved, almost one order of magnitude below the requirements for XENON1T and even sufficient for future dark matter experiments using liquid xenon, such as XENONnT and DARWIN.

physics.ins-det↗

Effective field theory search for high-energy nuclear recoils using the XENON100 dark matter detector

We report on WIMP search results in the XENON100 detector using a non-relativistic effective field theory approach. The data from science run II (34 kg $\times$ 224.6 live days) was re-analyzed, with an increased recoil energy interval compared to previous analyses, ranging from $(6.6 - 240)~\mathrm{keV_\mathrm{nr}}$. The data is found to be compatible with the background-only hypothesis. We present 90% confidence level exclusion limits on the coupling constants of WIMP-nucleon effective operators using a binned profile likelihood method. We also consider the case of inelastic WIMP scattering, where incident WIMPs may up-scatter to a higher mass state, and set exclusion limits on this model as well.

astro-ph.CO↗

Material radioassay and selection for the XENON1T dark matter experiment

The XENON1T dark matter experiment aims to detect Weakly Interacting Massive Particles (WIMPs) through low-energy interactions with xenon atoms. To detect such a rare event necessitates the use of radiopure materials to minimize the number of background events within the expected WIMP signal region. In this paper we report the results of an extensive material radioassay campaign for the XENON1T experiment. Using gamma-ray spectroscopy and mass spectrometry techniques, systematic measurements of trace radioactive impurities in over one hundred samples within a wide range of materials were performed. The measured activities allowed for stringent selection and placement of materials during the detector construction phase and provided the input for XENON1T detection sensitivity estimates through Monte Carlo simulations.

physics.ins-det↗