SearcharxivSearch

arXiv subjects

A. Burenkov

Publications and source records attributed to A. Burenkov.

At least 19 recordsLinked to original sources

VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO

Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area avalanche photodiodes. The next generation double beta decay experiment, nEXO, with a 5 tonne liquid xenon time projection chamber, will use SiPMs for detecting the $178\,\text{nm}$ xenon scintillation light, in order to achieve an energy resolution of $σ/ Q_{ββ} = 1\, \%$. This paper presents recent measurements of the VUV-HD generation SiPMs from Fondazione Bruno Kessler in two complementary setups. It includes measurements of the photon detection efficiency with gaseous xenon scintillation light in a vacuum setup and dark measurements in a dry nitrogen gas setup. We report improved photon detection efficiency at $175\,\text{nm}$ compared to previous generation devices, that would meet the criteria of nEXO. Furthermore, we present the projected nEXO detector light collection and energy resolution that could be achieved by using these SiPMs.

physics.ins-det

Imaging individual barium atoms in solid xenon for barium tagging in nEXO

The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or 'tagging', of the $^{136}$Ba daughter atom from double beta decay of $^{136}$Xe provides a technique for eliminating backgrounds in the nEXO neutrinoless double beta decay experiment. The tagging scheme studied in this work utilizes a cryogenic probe to trap the barium atom in solid xenon, where the barium atom is tagged via fluorescence imaging in the solid xenon matrix. Here we demonstrate imaging and counting of individual atoms of barium in solid xenon by scanning a focused laser across a solid xenon matrix deposited on a sapphire window. When the laser sits on an individual atom, the fluorescence persists for $\sim$30~s before dropping abruptly to the background level, a clear confirmation of one-atom imaging. No barium fluorescence persists following evaporation of a barium deposit to a limit of $\leq$0.16\%. This is the first time that single atoms have been imaged in solid noble element. It establishes the basic principle of a barium tagging technique for nEXO.

physics.ins-det

Star formation in outer rings of S0 galaxies. I. NGC 6534 and MCG 11-22-015

Though S0 galaxies are usually thought to be `red and dead', they often demonstrate star formation organized in ring structures. We try to clarify the nature of this phenomenon and its difference from star formation in spiral galaxies. Two early-type galaxies with outer rings, NGC 6534 and MCG 11-22-015, are selected to be studied. The ionized gas is excited by young stars in the ring of NGC 6534 and partly by shocks -- in MCG 11-22-015. The oxygen abundances in the HII regions of the rings are close to solar. We estimate the star formation rates (SFR) in the two outer rings of the galaxies by using several SFR indicators derived from narrow-band photometry in the H-alpha emission line and archival GALEX ultraviolet images of the galaxies. The derived SFRs allow to qualitatively restore star formation histories (SFH) in the rings: in NGC 6534 the SFH is flat during the last 100-200 Myr, and in MCG 11-22-015 the star formation has started only a few Myr ago. We suggest that the rings in NGC 6534 and MCG 11-22-015 have different natures: the former is a resonant one supplied with gas perhaps through tidal effects, and the latter has been produced by a satellite accretion. Recent outer gas accretion is implied in both cases.

astro-ph.GA

Sensitivity and discovery potential of the proposed nEXO experiment to neutrinoless double beta decay

The next-generation Enriched Xenon Observatory (nEXO) is a proposed experiment to search for neutrinoless double beta ($0νββ$) decay in $^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years using $5\times10^3$ kg of isotopically enriched liquid-xenon in a time projection chamber. This improvement of two orders of magnitude in sensitivity over current limits is obtained by a significant increase of the $^{136}$Xe mass, the monolithic and homogeneous configuration of the active medium, and the multi-parameter measurements of the interactions enabled by the time projection chamber. The detector concept and anticipated performance are presented based upon demonstrated realizable background rates.

nucl-ex

nEXO Pre-Conceptual Design Report

The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of approximately $10^{28}$ years. This represents an improvement in sensitivity of about two orders of magnitude with respect to current results. Based on the experience gained from EXO-200 and the effectiveness of xenon purification techniques, we expect the background to be dominated by external sources of radiation. The sensitivity increase is, therefore, entirely derived from the increase of active mass in a monolithic and homogeneous detector, along with some technical advances perfected in the course of a dedicated R&D program. Hence the risk which is inherent to the construction of a large, ultra-low background detector is reduced, as the intrinsic radioactive contamination requirements are generally not beyond those demonstrated with the present generation $0νββ$ decay experiments. Indeed, most of the required materials have been already assayed or reasonable estimates of their properties are at hand. The details described herein represent the base design of the detector configuration as of early 2018. Where potential design improvements are possible, alternatives are discussed. This design for nEXO presents a compelling path towards a next generation search for $0νββ$, with a substantial possibility to discover physics beyond the Standard Model.

physics.ins-det

Study of Silicon Photomultiplier Performance in External Electric Fields

We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estimated uncertainties. No observable physical damage to the bulk or surface of the devices was caused by the exposure.

physics.ins-det

COHERENT Collaboration data release from the first observation of coherent elastic neutrino-nucleus scattering

This release includes data and information necessary to perform independent analyses of the COHERENT result presented in Akimov et al., arXiv:1708.01294 [nucl-ex]. Data is shared in a binned, text-based format, including both "signal" and "background" regions, so that counts and associated uncertainties can be quantitatively calculated for the purpose of separate analyses. This document describes the included information and its format, offering some guidance on use of the data. Accompanying code examples show basic interaction with the data using Python.

nucl-ex

COHERENT 2018 at the Spallation Neutron Source

The primary goal of the COHERENT collaboration is to measure and study coherent elastic neutrino-nucleus scattering (CEvNS) using the high-power, few-tens-of-MeV, pulsed source of neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The COHERENT collaboration reported the first detection of CEvNS [Akimov:2017ade] using a CsI[Na] detector. At present the collaboration is deploying four detector technologies: a CsI[Na] scintillating crystal, p-type point-contact germanium detectors, single-phase liquid argon, and NaI[Tl] crystals. All detectors are located in the neutron-quiet basement of the SNS target building at distances 20-30 m from the SNS neutrino source. The simultaneous measurement in all four COHERENT detector subsystems will test the $N^2$ dependence of the cross section and search for new physics. In addition, COHERENT is measuring neutrino-induced neutrons from charged- and neutral-current neutrino interactions on nuclei in shielding materials, which represent a non-negligible background for CEvNS as well as being of intrinsic interest. The Collaboration is planning as well to look for charged-current interactions of relevance to supernova and weak-interaction physics. This document describes concisely the COHERENT physics motivations, sensitivity, and next plans for measurements at the SNS to be accomplished on a few-year timescale.

physics.ins-det

Characterization of an Ionization Readout Tile for nEXO

A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3~mm wide, on a 10~\si{\cm} $\times$ 10~\si{\cm} fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale nEXO experiment to search for neutrinoless double-beta decay. Modular by design, an array of tiles can cover a sizable area. The width of each strip is small compared to the size of the tile, so a Frisch grid is not required. A grid-less, tiled anode design is beneficial for an experiment such as nEXO, where a wire tensioning support structure and Frisch grid might contribute radioactive backgrounds and would have to be designed to accommodate cycling to cryogenic temperatures. The segmented anode also reduces some degeneracies in signal reconstruction that arise in large-area crossed-wire time projection chambers. A prototype tile was tested in a cell containing liquid xenon. Very good agreement is achieved between the measured ionization spectrum of a $^{207}$Bi source and simulations that include the microphysics of recombination in xenon and a detailed modeling of the electrostatic field of the detector. An energy resolution $σ/E$=5.5\% is observed at 570~\si{keV}, comparable to the best intrinsic ionization-only resolution reported in literature for liquid xenon at 936~V/\si{cm}.

physics.ins-det

Measurements of the ion fraction and mobility of alpha and beta decay products in liquid xenon using EXO-200

Alpha decays in the EXO-200 detector are used to measure the fraction of charged $^{218}\mathrm{Po}$ and $^{214}\mathrm{Bi}$ daughters created from alpha and beta decays, respectively. $^{222}\mathrm{Rn}$ alpha decays in liquid xenon (LXe) are found to produce $^{218}\mathrm{Po}^{+}$ ions $50.3 \pm 3.0\%$ of the time, while the remainder of the $^{218}\mathrm{Po}$ atoms are neutral. The fraction of $^{214}\mathrm{Bi}^{+}$ from $^{214}\mathrm{Pb}$ beta decays in LXe is found to be $76.4 \pm 5.7\%$, inferred from the relative rates of $^{218}\mathrm{Po}$ and $^{214}\mathrm{Po}$ alpha decays in the LXe. The average velocity of $^{218}\mathrm{Po}$ ions is observed to decrease for longer drift times. Initially the ions have a mobility of $0.390 \pm 0.006~\mathrm{cm}^2/(\mathrm{kV}~\mathrm{s})$, and at long drift times the mobility is $0.219 \pm 0.004~\mathrm{cm}^2/(\mathrm{kV}~\mathrm{s})$. Time constants associated with the change in mobility during drift of the $^{218}\mathrm{Po}^{+}$ ions are found to be proportional to the electron lifetime in the LXe.

nucl-ex

An Optimal Energy Estimator to Reduce Correlated Noise for the EXO-200 Light Readout

The energy resolution of the EXO-200 detector is limited by electronics noise in the measurement of the scintillation response. Here we present a new technique to extract optimal scintillation energy measurements for signals split across multiple channels in the presence of correlated noise. The implementation of these techniques improves the energy resolution of the detector at the neutrinoless double beta decay Q-value from $\left[1.9641\pm 0.0039\right]\%$ to $\left[1.5820\pm 0.0044\right]\%$.

physics.ins-det

Search for $2νββ$ decay of $^{136}$Xe to the 0$_1^+$ excited state of $^{136}$Ba with EXO-200

EXO-200 is a single phase liquid xenon detector designed to search for neutrinoless double-beta decay of $^{136}$Xe to the ground state of $^{136}$Ba. We report here on a search for the two-neutrino double-beta decay of $^{136}$Xe to the first $0^+$ excited state, $0^+_1$, of $^{136}$Ba based on a 100 kg$\cdot$yr exposure of $^{136}$Xe. Using a specialized analysis employing a machine learning algorithm, we obtain a 90% CL half-life sensitivity of $1.7 \times 10^{24}$ yr. We find no statistically significant evidence for the $2νββ$ decay to the excited state resulting in a lower limit of $T^{2ν}_{1/2}$ ($0^+ \rightarrow 0^+_1$) $> 6.9 \times 10^{23}$ yr at 90% CL. This observed limit is consistent with the estimated half-life of $2.5\times10^{25}$ yr.

nucl-ex

Measurement of the Drift Velocity and Transverse Diffusion of Electrons in Liquid Xenon with the EXO-200 Detector

The EXO-200 Collaboration is searching for neutrinoless double beta decay using a liquid xenon (LXe) time projection chamber. This measurement relies on modeling the transport of charge deposits produced by interactions in the LXe to allow discrimination between signal and background events. Here we present measurements of the transverse diffusion constant and drift velocity of electrons at drift fields between 20~V/cm and 615~V/cm using EXO-200 data. At the operating field of 380~V/cm EXO-200 measures a drift velocity of 1.705$_{-0.010}^{+0.014}$~mm/$μ$s and a transverse diffusion coefficient of 55$\pm$4~cm$^2$/s.

physics.ins-det

Cosmogenic Backgrounds to 0νββ in EXO-200

As neutrinoless double-beta decay experiments become more sensitive and intrinsic radioactivity in detector materials is reduced, previously minor contributions to the background must be understood and eliminated. With this in mind, cosmogenic backgrounds have been studied with the EXO-200 experiment. Using the EXO-200 TPC, the muon flux (through a flat horizontal surface) underground at the Waste Isolation Pilot Plant (WIPP) has been measured to be Φ = 4.07 $\pm$ 0.14 (sys) $\pm$ 0.03 (stat) $\times$ $10^{-7}$cm$^{-2}$ s$^{-1}$, with a vertical intensity of $I_{v}$ = 2.97$^{+0.14}_{-0.13}$ (sys) $\pm$ 0.02 (stat) $\times$ $10^{-7}$cm$^{-2}$ s$^{-1}$ sr$^{-1}$. Simulations of muon-induced backgrounds identified several potential cosmogenic radionuclides, though only 137Xe is a significant background for the 136Xe 0νββ search with EXO-200. Muon-induced neutron backgrounds were measured using γ-rays from neutron capture on the detector materials. This provided a measurement of 137Xe yield, and a test of the accuracy of the neutron production and transport simulations. The independently measured rates of 136Xe neutron capture and of 137Xe decay agree within uncertainties. Geant4 and FLUKA simulations were performed to estimate neutron capture rates, and these estimates agreed to within ~40% or better with measurements. The ability to identify 136Xe(n,γ) events will allow for rejection of 137Xe backgrounds in future 0νββ analyses.

nucl-ex

The COHERENT Experiment at the Spallation Neutron Source

The COHERENT collaboration's primary objective is to measure coherent elastic neutrino-nucleus scattering (CEvNS) using the unique, high-quality source of tens-of-MeV neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). In spite of its large cross section, the CEvNS process has never been observed, due to tiny energies of the resulting nuclear recoils which are out of reach for standard neutrino detectors. The measurement of CEvNS has now become feasible, thanks to the development of ultra-sensitive technology for rare decay and weakly-interacting massive particle (dark matter) searches. The CEvNS cross section is cleanly predicted in the standard model; hence its measurement provides a standard model test. It is relevant for supernova physics and supernova-neutrino detection, and enables validation of dark-matter detector background and detector-response models. In the long term, precision measurement of CEvNS will address questions of nuclear structure. COHERENT will deploy multiple detector technologies in a phased approach: a 14-kg CsI[Na] scintillating crystal, 15 kg of p-type point-contact germanium detectors, and 100 kg of liquid xenon in a two-phase time projection chamber. Following an extensive background measurement campaign, a location in the SNS basement has proven to be neutron-quiet and suitable for deployment of the COHERENT detector suite. The simultaneous deployment of the three COHERENT detector subsystems will test the $N^2$ dependence of the cross section and ensure an unambiguous discovery of CEvNS. This document describes concisely the COHERENT physics motivations, sensitivity and plans for measurements at the SNS to be accomplished on a four-year timescale.

physics.ins-det

First Search for Lorentz and CPT Violation in Double Beta Decay with EXO-200

A search for Lorentz- and CPT-violating signals in the double beta decay spectrum of $^{136}$Xe has been performed using an exposure of 100 kg$\cdot$yr with the EXO-200 detector. No significant evidence of the spectral modification due to isotropic Lorentz-violation was found, and a two-sided limit of $-2.65 \times 10^{-5 } \; \textrm{GeV} < \mathring{a}^{(3)}_{\text{of}} < 7.60 \times 10^{-6} \; \textrm{GeV}$ (90% C.L.) is placed on the relevant coefficient within the Standard-Model Extension (SME). This is the first experimental study of the effect of the SME-defined oscillation-free and momentum-independent neutrino coupling operator on the double beta decay process.

nucl-ex

Investigation of radioactivity-induced backgrounds in EXO-200

The search for neutrinoless double-beta decay (0νββ) requires extremely low background and a good understanding of their sources and their influence on the rate in the region of parameter space relevant to the 0νββ signal. We report on studies of various β- and γ-backgrounds in the liquid- xenon-based EXO-200 0νββ experiment. With this work we try to better understand the location and strength of specific background sources and compare the conclusions to radioassay results taken before and during detector construction. Finally, we discuss the implications of these studies for EXO-200 as well as for the next-generation, tonne-scale nEXO detector.

physics.ins-det

Search for Majoron-emitting modes of double-beta decay of $^{136}$Xe with EXO-200

EXO-200 is a single phase liquid xenon detector designed to search for neutrinoless double-beta decay of $^{136}$Xe. Here we report on a search for various Majoron-emitting modes based on 100 kg$\cdot$yr exposure of $^{136}$Xe. A lower limit of $T^{^{136}Xe}_{1/2} >1.2 \cdot 10^{24}$ yr at 90% C.L. on the half-life of the spectral index = 1 Majoron decay was obtained, corresponding to a constraint on the Majoron-neutrino coupling constant of $|< g^{M}_{ee} >|<$ (0.8-1.7)$\cdot$10$^{-5}$.

hep-ex