GEM operation in helium and neon at low temperatures

We study the performance of Gas Electron Multipliers (GEMs) in gaseous He, Ne and Ne+H2 at temperatures in the range of 2.6-293 K. In He, at temperatures between 62 and 293 K, the triple-GEM structures often operate at rather high gains, exceeding 1000. There is an indication that this high gain is achieved by Penning effect in the gas impurities released by outgassing. At lower temperatures the gain-voltage characteristics are significantly modified probably due to the freeze-out of impurities. In particular, the double-GEM and single-GEM structures can operate down to 2.6 K at gains reaching only several tens at a gas density of about 0.5 g/l; at higher densities the maximum gain drops further. In Ne, the maximum gain also drops at cryogenic temperatures. The gain drop in Ne at low temperatures can be reestablished in Penning mixtures of Ne+H2: very high gains, exceeding 10000, have been obtained in these mixtures at 50-60 K, at a density of 9.2 g/l corresponding to that of saturated Ne vapor near 27 K. The results obtained are relevant in the fields of two-phase He and Ne detectors for solar neutrino detection and electron avalanching at low temperatures.

physics.ins-det↗

Cryogenic avalanche detectors based on gas electron multipliers

We study the performances of gaseous and two-phase (liquid-gas) cryogenic detectors of ionizing radiation based on gas electron multipliers (GEMs) and operated in an avalanche mode in pure noble gases. The gas amplification in He, Ar and Kr is systematically studied at low temperatures, using triple-GEM multipliers. High gains, exceeding 10^4, were obtained in these gases in the range of 120-300 K. Stable electron avalanching was demonstrated in a saturated Kr vapor in the two-phase mode. These results are relevant for understanding basic mechanisms of electron avalanching at low temperatures and for applications in cryogenic particle detectors, in particular in dark matter and solar neutrino detectors.

physics.ins-det↗

First results from cryogenic avalanche detectors based on gas electron multipliers

We study the performance of gaseous and two-phase (liquid-gas) cryogenic detectors of ionizing radiation, based on gas electron multipliers (GEMs). For the first time, high gas gains, exceeding 10^4, were obtained in pure He, Ar and Kr at low temperatures and the stable avalanche mode of operation was observed in the two-phase cryogenic detector in Kr. The electron avalanching at low temperatures, in the range of 120-300 K, is systematically studied.

physics.ins-det↗

Further studies of GEM performance in dense noble gases

We further study the performance of single, double and triple Gas Electron Multiplier (GEM) detectors in pure noble gases at high pressures, in the range of 1-10 atm. We confirm that light noble gases, in particular He and its mixtures with Kr, have the highest gain, reaching 10^6, and an unusual gain dependence on pressure. Effects of the number of GEMs, GEM hole diameter and pitch are investigated in detail. In He, avalanche-induced secondary scintillations are observed at high gains, using the metal photocathode. These results are relevant in the field of avalanche mechanism in noble gases and X-ray, neutron and cryogenic particle detectors.

physics.ins-det↗

Triple GEM operation in compressed He and Kr

We study the performance of the triple GEM (Gas Electron Multiplier) detector in pure noble gases He and Kr at high pressures, varying from 1 to 15 atm. The operation in these gases is compared to that recently studied in Ne, Ar and Xe. It turned out that light noble gases, He and Ne, have superior performance: the highest gain, approaching 10^5, and an unusual gain dependence on pressure. In particular, the maximum gain in He and Ne does not decrease with pressure, in contrast to Ar, Kr and Xe. These results are of high relevance for understanding basic mechanisms of electron avalanching in noble gases and for applications in cryogenic particle detectors, X-ray imaging and neutron detectors.

physics.ins-det↗

Study of ion feedback in multi-GEM structures

We study the feedback of positive ions in triple and quadruple Gas Electron Multiplier (GEM) detectors. The effects of GEM hole diameter, detector gain, applied voltages, number of GEMs and other parameters on ion feedback are investigated in detail. In particular, it was found that the ion feedback is independent of the gas mixture and the pressure. In the optimized multi-GEM structure, the ion feedback current can be suppressed down to 0.5% of the anode current, at a drift field of 0.1 kV/cm and gain of 10^4. A simple model of ion feedback in multi-GEM structures is suggested. The results obtained are relevant to the performance of time projection chambers and gas photomultipliers.

physics.ins-det↗

Physics of multi-GEM structures

We show that physics of multi-GEM structures is rather complex, regarding the number of phenomena affecting detector performance. The high-pressure operation in noble gases and the ion feedback are considered in more detail. It is proposed that the dominant avalanche mechanism in He and Ne, at high pressures, is the associative ionization. Ion feedback effects related to the dependence on gas, pressure and gain and to possible avalanche extension outside the GEM holes are discussed.

physics.ins-det↗

Performance of the triple-GEM detector with optimized 2-D readout in high intensity hadron beam

Multiple-GEM detectors are considered to be good candidates for tracking devices in experiments with high hadronic background. We present the results of the triple-GEM detectors beam test in a high intensity pion beam. The detectors had an optimized two-dimensional readout with minimized strip capacitance. Such optimization permitted the starting point of the efficiency plateau down to a gain of 5000. The probability of GEM discharges induced by heavily ionizing particles has been measured as a function of gain: at a gain of 20000 it amounts to 10^(-11) per incident particle. Such a value will ensure safe operation of the detector in the conditions of forward region of the LHC experiments.

physics.ins-det↗

High pressure operation of the triple-GEM detector in pure Ne, Ar and Xe

We study the performance of the triple-GEM (Gas Electron Multiplier) detector in pure noble gases Ne, Ar and Xe, at different pressures varying from 1 to 10 atm. In Ar and Xe, the maximum attainable gain of the detector abruptly drops down for pressures exceeding 3 atm. In contrast, the maximum gain in Ne was found to increase with pressure, reaching a value of 100,000 at 7 atm. The results obtained are of particular interest for developing noble gas-based cryogenic particle detectors for solar neutrino and dark matter search.

physics.ins-det↗