Performance of the LHCb muon detector in Run 3

In Run 3 of the LHC, the instantaneous luminosity at the LHCb interaction point has been increased by a factor of five, from $4\times 10^{32}\rm{cm}^{-2}\rm{s}^{-1}$ to $2\times 10^{33}\rm{cm}^{-2}\rm{s}^{-1}$. Several hardware interventions, including a complete overhaul of the readout electronics, have been carried out on the muon detector. The muon identification algorithms in the software trigger were improved with the aim of ensuring Run 2 performance under a higher particle rate. The operation and calibration of the upgraded muon detector are presented. The muon detection efficiency and muon identification performance are evaluated on data calibration samples collected during the year 2024. A muon identification efficiency above 90\% with sub-percent hadron misidentification probability is achieved by exploiting the pattern of hits in the muon detector.

hep-ex

Long-term Operation of the Multi-Wire-Proportional-Chambers of the LHCb Muon System

The muon detector of LHCb, which comprises 1368 multi-wire-proportional-chambers (MWPC) for a total area of 435 m2, is the largest instrument of its kind exposed to such a high-radiation environment. In nine years of operation, from 2010 until 2018, we did not observe appreciable signs of ageing of the detector in terms of reduced performance. However, during such a long period, many chamber gas gaps suffered from HV trips. Most of the trips were due to Malter-like effects, characterised by the appearance of local self-sustained high currents, presumably originating from impurities induced during chamber production. Very effective, though long, recovery procedures were implemented with a HV training of the gaps in situ while taking data. The training allowed most of the affected chambers to be returned to their full functionality and the muon detector efficiency to be kept close to 100%. The possibility of making the recovery faster and even more effective by adding a small percentage of oxygen in the gas mixture has been studied and successfully tested.

physics.ins-det

Measurement of the front-end dead-time of the LHCb muon detector and evaluation of its contribution to the muon detection inefficiency

A method is described which allows to deduce the dead-time of the front-end electronics of the LHCb muon detector from a series of measurements performed at different luminosities at a bunch-crossing rate of 20 MHz. The measured values of the dead-time range from 70 ns to 100 ns. These results allow to estimate the performance of the muon detector at the future bunch-crossing rate of 40 MHz and at higher luminosity.

physics.ins-det