SearcharxivSearch

arXiv subjects

A. D'Addabbo

Publications and source records attributed to A. D'Addabbo.

At least 19 recordsLinked to original sources

Background of the BULLKID detector array operated with moderate shield on surface

We present the operation with moderate radiation shield in a surface laboratory of BULLKID (BULky and Low-threshold Kinetic Inductance Detector), a cryogenic detector for searches of light Dark Matter or Coherent Elastic Neutrino-Nucleus Scattering. The detector consists of an array of 60 cubic silicon particle absorbers of 0.34 g each, sensed by cryogenic kinetic inductance detectors. The analysis presented focuses on data from 15 elements of the array, with two central units used to evaluate the background and with their surrounding elements used as veto. The low energy spectrum resulting from an exposure of 290 hours to ambient backgrounds, acquired with the use of external and internal radiation shields, is compatible with the simulations at the level of $(6.8\pm0.4\,{\rm stat.}\pm0.1\,{\rm syst.})\times10^4$ counts / keV kg days from 2 keV down to an energy of 600 eV. The region between 225 eV and 600 eV shows a rise in background in disagreement with the simulations, while not sharing some of the key traits of the low energy excess observed in other cryogenic experiments. The high energy spectrum shape is in overall agreement with the simulations and displays the typical particle-induced X-ray emission of the surrounding lead.

hep-ex

Search for Sterile Neutrinos with CUPID-0

Sterile neutrinos are well-motivated extensions of the Standard Model, introduced to address fundamental questions such as the origin of neutrino masses and the nature of dark matter. Exploiting the precise data reconstruction achieved by the CUPID-0 experiment, we searched for spectral distortions in the double $\beta$-decay of $^{82}$Se compatible with the emission of a sterile neutrino. The analysis relies on the construction of a detailed background model down to 200 keV, enabling an accurate characterization of the main sources of contamination. Using a Zn$^{82}$Se exposure of 9.95 kg$\cdot$yr, we explored sterile neutrino mass hypotheses between 0.5 MeV and 1.5 MeV. No evidence for a signal was observed in any scenario; therefore, we derived 90% C.I. upper limits on the active-sterile mixing probability $\sin^2\theta$, obtaining the most stringent bound, $\sin^2\theta<8\times 10^{-3}$, for a sterile neutrino mass of 0.7 MeV.

nucl-ex

Projected sensitivity to light WIMP-like particles of the BULLKID-DM experiment

BULLKID-DM is an experiment designed for the direct searches of particle dark matter candidates with mass around 1 GeV, or below, and cross-section with nucleons smaller than $10^{-40}$ cm$^2$. The detector consists of a stack of diced silicon wafers, acting as arrays of particle absorbers, sensed by multiplexed Kinetic Inductance Detectors. The target will amount to 800 g subdivided in more than 2000 silicon dice, with the aim of controlling the background from natural radioactivity by creating a fully active structure and by applying fiducialization techniques. In this work we present the projected sensitivity of BULLKID-DM to light WIMP-like particles considering also the other future experiments in the field.

physics.ins-det

Vibrational sensing at mK temperatures in dry dilution refrigerators using commercial accelerometers for diverse fundamental physics applications

This article presents an evaluation of off-the-shelf commercial accelerometers at the mixing chamber stage of a cryogen-free dilution refrigerator at temperatures down to 8 mK. In addition, we present results of radioassay of accelerometers using a high purity germanium detector counting setup. Cryogen-free dilution refrigerators using pulse-tube cryocoolers (PTs) -- due to recent advances in their cooling capacity, long-term stability, and operational costs -- have become ubiquitous tools in a wide range of fields ranging from experimental particle physics to quantum information sciences. However, vibrations induced by PTs can negatively impact the experimental payload in these applications. This work demonstrates that commercially available accelerometers can not only measure vibrations at millikelvin cryogenic temperatures but also pave the way for continuous, in situ, real-time vibration monitoring of dry dilution refrigerators. This monitoring capability facilitates applications such as real-time denoising for vibration-sensitive experiments, thereby enabling ongoing noise assessment and mitigation.

physics.ins-det

End-to-End Data Analysis Methods for the CUORE Experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) experiment set the most stringent limit on the neutrinoless double-beta ($0\nu\beta\beta$) decay half-life of $^{130}$Te with 2 ton yr TeO$_2$ analyzed exposure. In addition to $0\nu\beta\beta$ decay, the CUORE detector -- a ton-scale array of nearly 1000 cryogenic calorimeters operating at $\sim$10 mK -- is capable of searching for other rare decays and interactions over a broad energy range. For our searches, we leverage the available information of each calorimeter by performing its optimization, data acquisition, and analysis independently. We describe the analysis tools and methods developed for CUORE and their application to build high-quality datasets for numerous physics searches. In particular, we describe in detail our evaluation of the energy-dependent detector response and signal efficiency used in the most recent search for $0\nu\beta\beta$ decay.

nucl-ex

Energy calibration of bulk events in the BULLKID detector

BULLKID is a cryogenic, solid-state detector designed for direct searches of particle Dark Matter candidates, with mass $\lesssim 1$ GeV/c$^2$, and coherent neutrino-nucleus scattering. It is based on an array of dice carved in 5 mm thick silicon crystal, sensed by phonon-mediated Kinetic Inductance Detectors. In previous works, the array was calibrated with bursts of optical photons, which are absorbed in the first hundreds nanometers of the dice and give rise to surface events. In this work, we present the reconstruction of bulk events through the 59.5 keV $\gamma$-ray generated by an $^{241}$Am source, which emulates more closely the interaction of Dark Matter and neutrinos. The peak resolution is $5\%~(\sigma)$ and its position is shifted by less than $10\%$ with respect to the optical calibration. We observe that the resolution is further improved by a factor $2$ combining the signal from neighboring dice. These results confirm the performance of the detector in view of the physics goals of the BULLKID-DM experiment for dark matter search.

physics.ins-det

Real-Time Readout System Design for the BULLKID-DM Experiment: Enhancing Dark Matter Search Capabilities

The BULLKID-DM experiment aims to detect WIMP-like potential Dark Matter particles with masses below 1 GeV/c^2. Sensing these particles is challenging, as it requires nuclear recoil detectors characterized by high exposure and an energy threshold in the order of 100 eV, thus exceeding the capabilities of conventional semiconductor detectors. BULLKID-DM intends to tackle this challenge by using cryogenic Kinetic Inductance Detectors (MKIDs) with exceptional energy thresholds to sense a target with a total mass of 800 g across 16 wafers, divided into over 2000 individually instrumented silicon dice. The MKIDs on each wafer are coupled to a single transmission line and read using a frequency division multiplexing approach by the room-temperature data acquisition. In this contribution, we describe and assess the design of the room-temperature readout electronics system, including the selected hardware components and the FPGA firmware which contains the real-time signal processing stages for tone generation, frequency demultiplexing, and event triggering. We evaluate the system on the ZCU216 board, a commercial evaluation card built around a Radio-Frequency System-on-Chip (RFSoC) with integrated high-speed DACs and ADCs, and connected it to a custom-designed analog front-end for signal conditioning.

physics.ins-det

Reconstruction of cosmic-ray muon events with CUORE

We report the in-situ 3D reconstruction of through-going muons in the CUORE experiment, a cryogenic calorimeter array searching for neutrinoless double beta ($0\nu\beta\beta$) decay, leveraging the segmentation of the detector. Due to the slow time response of the detector, time-of-flight estimation is not feasible. Therefore, the track reconstruction is performed using a multi-objective optimization algorithm that relies on geometrical information from the detector as a whole. We measure the integral flux of cosmic-ray muons underground at the {\it Laboratori Nazionali del Gran Sasso}, and find our value to be in good agreement with other experiments that have performed a similar measurement. To our knowledge, this work represents the first demonstration of 3D particle tracking and reconstruction of through-going muons with per-event angular determination in a millikelvin cryogenic detector array. The analysis performed for this work will be critical for validating the muon-related background in CUPID, a next-generation $0\nu\beta\beta$ experiment, and for follow-up studies on detector response and on delayed products induced by cosmic-ray muons.

physics.ins-det

Description of CRESST-II and CRESST-III pulse shape data

A set of data from 68 cryogenic detectors operated in the CRESST dark matter search experiment between 2013 and 2019 was collected and labeled to train binary classifiers for data cleaning. Here, we describe the data set and how the trained models can be applied to new data. The data and models are available online.

physics.ins-det

Description of CRESST-III lithium aluminate data

Two detector modules with lithium aluminate targets were operated in the CRESST underground setup between February and June 2021. The data collected in this period was used to set the currently strongest cross-section upper limits on the spin-dependent interaction of dark matter (DM) with protons and neutrons for the mass region between 0.25 and 1.5 GeV/c$^2$. The data are available online. In this document, we describe how the data set should be used to reproduce our dark matter results.

hep-ex

The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment

Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta ($0\nu\beta\beta$) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here we report the first detection of marine microseismic vibrations using mK-scale calorimeters. This study employs a multi-device analysis correlating data from CUORE, the leading experiment in the search for $0\nu\beta\beta$ decay with mK-scale calorimeters and the Copernicus Earth Observation program, revealing the seasonal impact of Mediterranean Sea activity on CUORE's energy thresholds, resolution, and sensitivity over four years. The detection of marine microseisms underscores the need to address faint environmental noise in ultra-sensitive experiments. Understanding how such noise couples to the detector and developing mitigation strategies is essential for next-generation experiments. We demonstrate one such strategy: a noise decorrelation algorithm implemented in CUORE using auxiliary sensors, which reduces vibrational noise and improves detector performance. Enhancing sensitivity to $0\nu\beta\beta$ decay and to rare events with low-energy signatures requires identifying unresolved noise sources, advancing noise reduction methods, and improving vibration suppression systems, all of which inform the design of next-generation rare event experiments.

physics.ins-det

Sensitivity of the CUPID experiment to $0\nu\beta\beta$ decay of $^{100}$Mo

CUPID is a next-generation bolometric experiment to search for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{100}$Mo using Li$_2$MoO$_4$ scintillating crystals. It will operate 1596 crystals at $\sim$10 mK in the CUORE cryostat at the Laboratori Nazionali del Gran Sasso in Italy. Each crystal will be facing two Ge-based bolometric light detectors for $\alpha$ rejection. We compute the discovery and the exclusion sensitivity of CUPID to $0\nu\beta\beta$ in a Frequentist and a Bayesian framework. This computation is done numerically based on pseudo-experiments. For the CUPID baseline scenario, with a background and an energy resolution of $1.0 \times 10^{-4}$ counts/keV/kg/yr and 5 keV FWHM at the Q-value, respectively, this results in a Bayesian exclusion sensitivity (90% c.i.) of $\hat{T}_{1/2} > 1.6 \times 10^{27} \ \mathrm{yr}$, corresponding to the effective Majorana neutrino mass of $\hat{m}_{\beta\beta} < \ 9.6$ -- $28 \ \mathrm{meV}$. The Frequentist discovery sensitivity (3$\sigma$) is $\hat{T}_{1/2}= 1.0 \times 10^{27} \ \mathrm{yr}$, corresponding to $\hat{m}_{\beta\beta}= \ 12$ -- $36 \ \mathrm{meV}$.

nucl-ex

Half-life and precision shape measurement of 2{\nu}{\beta}{\beta} decay of $^{130}$Te

We present a new measurement of the 2nbb half-life of 130Te (T1/2) using the first complete model of the CUORE data, based on 1038 kg yr of collected exposure. Thanks to optimized data selection, we achieve a factor of two improvement in precision, obtaining T1/2 = (9.32 +0.05 -0.04 (stat.) +0.07 -0.07 (syst.)) x10^20 yr. The signal-to-background ratio is increased by 70% compared to our previous results, enabling the first application of the improved 2nbb formalism to 130Te. Within this framework, we determine a credibility interval for the effective axial coupling in the nuclear medium as a function of nuclear matrix elements. We also extract values for the higher-order nuclear matrix element ratios: second-to-first and third-to-first. The second-to-first ratio agrees with nuclear model predictions, while the third-to-first ratio deviates from theoretical expectations. These findings provide essential tests of nuclear models and key inputs for future 0nbb searches.

nucl-ex

Innovating Bolometers' Mounting: A Gravity-Based Approach

Cryogenic calorimeters, also known as bolometers, are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of $^{100}$Mo. The CUPID collaboration proposed an innovative approach to assembling bolometers in a stacked configuration, held in position solely by gravity. This gravity-based assembly method is unprecedented in the field of bolometers and offers several advantages, including relaxed mechanical tolerances and simplified construction. To assess and optimize its performance, we constructed a medium-scale prototype hosting 28 Li$_2$MoO$_4$ crystals and 30 Ge light detectors, both operated as cryogenic calorimeters at the Laboratori Nazionali del Gran Sasso (Italy). Despite an unexpected excess of noise in the light detectors, the results of this test proved (i) a thermal stability better than $\pm$0.5 mK at 10 mK, (ii) a good energy resolution of Li$_2$MoO$_4$ bolometers, (6.6 $\pm$ 2.2) keV FWHM at 2615 keV, and (iii) a Li$_2$MoO$_4$ light yield measured by the closest light detector of 0.36 keV/MeV, sufficient to guarantee the particle identification requested by CUPID.

physics.ins-det

CUPID, the CUORE Upgrade with Particle IDentification

CUPID, the CUORE Upgrade with Particle IDentification, is a next-generation experiment to search for neutrinoless double beta decay ($0\nu\beta\beta$) and other rare events using enriched Li$_2$$^{100}$MoO$_4$ scintillating bolometers. It will be hosted by the CUORE cryostat located at the Laboratori Nazionali del Gran Sasso in Italy. The main physics goal of CUPID is to search for $0\nu\beta\beta$\ of $^{100}$Mo with a discovery sensitivity covering the full neutrino mass regime in the inverted ordering scenario, as well as the portion of the normal ordering regime with lightest neutrino mass larger than 10 meV. With a conservative background index of 10$^{-4}$ cnts/(keV$\cdot$kg$\cdot$yr), 240 kg isotope mass, 5 keV FWHM energy resolution at 3 MeV and 10 live-years of data taking, CUPID will have a 90\% C.L. half-life exclusion sensitivity of 1.8 $\cdot$ 10$^{27}$ yr, corresponding to an effective Majorana neutrino mass ($m_{\beta\beta}$) sensitivity of 9--15 meV, and a $3\sigma$ discovery sensitivity of 1 $\cdot$ 10$^{27}$ yr, corresponding to an $m_{\beta\beta}$ range of 12--21 meV.

physics.ins-det

A likelihood framework for cryogenic scintillating calorimeters used in the CRESST dark matter search

Cryogenic scintillating calorimeters are ultrasensitive particle detectors for rare event searches, particularly for the search for dark matter and the measurement of neutrino properties. These detectors are made from scintillating target crystals generating two signals for each particle interaction. The phonon (heat) signal precisely measures the deposited energy independent of the type of interacting particle. The scintillation light signal yields particle discrimination on an event-by-event basis. This paper presents a likelihood framework modeling backgrounds and a potential dark matter signal in the two-dimensional plane spanned by phonon and scintillation light energies. We apply the framework to data from CaWO$_4$-based detectors operated in the CRESST dark matter search. For the first time, a single likelihood framework is used in CRESST to model the data and extract results on dark matter in one step by using a profile likelihood ratio test. Our framework simultaneously fits (neutron) calibration data and physics (background) data and allows combining data from multiple detectors. Although tailored to CaWO$_4$-targets and the CRESST experiment, the framework can easily be expanded to other materials and experiments using scintillating cryogenic calorimeters for dark matter search and neutrino physics.

astro-ph.CO

The environmental low-frequency background for macro-calorimeters at the millikelvin scale

Many of the most sensitive physics experiments searching for rare events, like neutrinoless double beta ($0νββ$) decay and dark matter interactions, rely on cryogenic macro-calorimeters operating at the mK-scale. Located underground at the Gran Sasso National Laboratory (LNGS), in central Italy, CUORE (Cryogenic Underground Observatory for Rare Events) is one of the leading experiments for the search of $0νββ$ decay, implementing the low-temperature calorimetric technology. We present a novel multi-detector analysis to correlate environmental phenomena with the low-frequency noise of low-temperature calorimeters. Indeed, the correlation of marine and seismic data with data from a pair of CUORE detectors indicates that cryogenic detectors are sensitive not only to intense vibrations generated by earthquakes, but also to the much fainter vibrations induced by marine microseisms in the Mediterranean Sea due to the motion of sea waves. Proving that cryogenic macro-calorimeters are sensitive to such environmental sources of noise opens the possibility of studying their impact on the detectors physics-case sensitivity. Moreover, this study could pave the road for technology developments dedicated to the mitigation of the noise induced by marine microseisms, from which the entire community of cryogenic calorimeters can benefit.

physics.ins-det

Search for fractionally charged particles with CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) is a detector array comprised by 988 5$\;$cm$\times$5$\;$cm$\times$5$\;$cm TeO$_2$ crystals held below 20 mK, primarily searching for neutrinoless double-beta decay in $^{130}$Te. Unprecedented in size amongst cryogenic calorimetric experiments, CUORE provides a promising setting for the study of exotic through-going particles. Using the first tonne-year of CUORE's exposure, we perform a search for hypothesized fractionally charged particles (FCPs), which are well-motivated by various Standard Model extensions and would have suppressed interactions with matter. No excess of FCP candidate tracks is observed over background, setting leading limits on the underground FCP flux with charges between $e/24-e/5$ at 90\% confidence level. Using the low background environment and segmented geometry of CUORE, we establish the sensitivity of tonne-scale sub-Kelvin detectors to diverse signatures of new physics.

hep-ex