Searcharxiv⌕ Search

arXiv subjects

A. D'Addabbo

Publications and source records attributed to A. D'Addabbo.

At least 91 records · Page 5Linked to original sources

An active noise cancellation technique for the CUORE Pulse Tube Cryocoolers

The Cryogenic Underground Observatory for Rare Events (CUORE) experiment at Gran Sasso National Laboratory of INFN searches for neutrinoless double beta decay using TeO2 crystals as cryogenic bolometers. The sensitivity of the measurement heavily depends on the energy resolution of the detector, therefore the success of the experiment stands on the capability to provide an extremely low noise environment. One of the most relevant sources of noise are the mechanical vibrations induced by the five Pulse Tube cryocoolers used on the cryogenic system which houses the detectors. To address this problem, we developed a system to control the relative phases of the pulse tube pressure oscillations, in order to achieve coherent superposition of the mechanical vibrations transmitted to the detectors. In the following, we describe this method and report on the results in applying it to the CUORE system.

physics.ins-det↗

First Result on the Neutrinoless Double Beta Decay of $^{82}$Se with CUPID-0

We report the result of the search for neutrinoless double beta decay of $^{82}$Se obtained with CUPID-0, the first large array of scintillating Zn$^{82}$Se cryogenic calorimeters implementing particle identification. We observe no signal in a 1.83 kg yr $^{82}$Se exposure and we set the most stringent lower limit on the \onu $^{82}$Se half-life T$^{0ν}_{1/2}>$ 2.4$\times \mathrm{10}^{24}$ yr (90\% credible interval), which corresponds to an effective Majorana neutrino mass m$_{ββ} <$ (376-770) meV depending on the nuclear matrix element calculations. The heat-light readout provides a powerful tool for the rejection of \al\ particles and allows to suppress the background in the region of interest down to (3.6$^{+1.9}_{-1.4}$)$\times$10$^{-3}$\ckky, an unprecedented level for this technique.

nucl-ex↗

NIKA 150 GHz polarization observations of the Crab nebula and its spectral energy distribution

The Crab nebula is a supernova remnant exhibiting a highly polarized synchrotron radiation at radio and millimeter wavelengths. It is the brightest source in the microwave sky with an extension of 7 by 5 arcminutes and commonly used as a standard candle for any experiment which aims at measuring the polarization of the sky. Though its spectral energy distribution has been well characterized in total intensity, polarization data are still lacking at millimetre wavelengths. We report in this paper high resolution (18 arcsec FWHM) observations of the Crab nebula in total intensity and linear polarization at 150 GHz with the NIKA camera. NIKA, operated at the IRAM 30 m telescope from 2012 to 2015, is a camera made of Lumped Element Kinetic Inductance Detectors (LEKIDs) observing the sky at 150 and 260 GHz. From these observations we are able to reconstruct the spatial distribution of the polarization degree and angle of the Crab nebula, which is found to be compatible with previous observations at lower and higher frequencies. Averaging across the source and using other existing data sets we find that the Crab nebula polarization angle is consistent with being constant over a wide range of frequencies with a value of -87.7$^\circ$ +- 0.3 in Galactic coordinates. We also present the first estimation of the Crab nebula spectral energy distribution polarized flux in a wide frequency range: 30-353 GHz. Assuming a single power law emission model we find that the polarization spectral index $β_{pol}$ = - 0.347 +- 0.026 is compatible with the intensity spectral index $β$ = - 0.323 +- 0.001.

astro-ph.CO↗

Al/Ti/Al phonon-mediated KIDs for UV-VIS light detection over large areas

The development of wide-area cryogenic light detectors with baseline energy resolution lower than 20 eV RMS is essential for next generation bolometric experiments searching for rare interactions. Indeed the simultaneous readout of the light and heat signals will enable background suppression through particle identification. Because of their excellent intrinsic energy resolution, as well as their well-established reproducibility, Kinetic Inductance Detectors (KIDs) are good candidates for the development of next generation light detectors. The CALDER project is investigating the potential of phonon-mediated KIDs. The first phase of the project allowed to reach a baseline resolution of 80 eV using a single KID made of aluminium on a 2x2 cm\tmrsup{$2$} silicon substrate acting as photon absorber. In this paper we present a new prototype detector implementing a trilayer aluminium-titanium-aluminium KID. Taking advantage of the superconducting proximity effect the baseline resolution improves down to 26 eV.

physics.ins-det↗

First Results from CUORE: A Search for Lepton Number Violation via $0νββ$ Decay of $^{130}$Te

The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-number--violating process: $^{130}$Te neutrinoless double-beta decay. Examining a total TeO$_2$ exposure of 86.3 kg$\cdot$yr, characterized by an effective energy resolution of (7.7 $\pm$ 0.5) keV FWHM and a background in the region of interest of (0.014 $\pm$ 0.002) counts/(keV$\cdot$kg$\cdot$yr), we find no evidence for neutrinoless double-beta decay. The median statistical sensitivity of this search is $7.0\times10^{24}$ yr. Including systematic uncertainties, we place a lower limit on the decay half-life of $T^{0ν}_{1/2}$($^{130}$Te) > $1.3\times 10^{25}$ yr (90% C.L.). Combining this result with those of two earlier experiments, Cuoricino and CUORE-0, we find $T^{0ν}_{1/2}$($^{130}$Te) > $1.5\times 10^{25}$ yr (90% C.L.), which is the most stringent limit to date on this decay. Interpreting this result as a limit on the effective Majorana neutrino mass, we find $m_{ββ}<(110 - 520)$ meV, where the range reflects the nuclear matrix element estimates employed.

nucl-ex↗

CUPID-0: the first array of enriched scintillating bolometers for 0νββdecay investigations

The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso, Italy, is the first large array of enriched scintillating cryogenic detectors for the investigation of $^{82}$Se neutrinoless double-beta decay (0$νββ$). CUPID-0 aims at measuring a background index in the region of interest (RoI) for 0$νββ$ at the level of 10$^{-3}$ c/keV/kg/y, the lowest value ever measured using cryogenic detectors. This result can be achieved by a state of the art technology for background suppression and thorough protocols and procedures for detector preparation and construction. In this paper, the different phases of the detector design and construction will be presented, from the material selection (for the absorber production) to the new and innovative detector structure. The successful construction of the detector lead to promising detector performance which are here preliminarily discussed

physics.ins-det↗

Study of Rare Nuclear Processes with CUORE

TeO2 bolometers have been used for many years to search for neutrinoless double beta decay in 130-Te. CUORE, a tonne-scale TeO2 detector array, recently published the most sensitive limit on the half-life, $T_{1/2}^{0ν} > 1.5 \times 10^{25}\,$yr, which corresponds to an upper bound of $140-400$~meV on the effective Majorana mass of the neutrino. While it makes CUORE a world-leading experiment looking for neutrinoless double beta decay, it is not the only study that CUORE will contribute to in the field of nuclear and particle physics. As already done over the years with many small-scale experiments, CUORE will investigate both rare decays (such as the two-neutrino double beta decay of 130-Te and the hypothesized electron capture in 123-Te), and rare processes (e.g., dark matter and axion interactions). This paper describes some of the achievements of past experiments that used TeO2 bolometers, and perspectives for CUORE.

nucl-ex↗

Low Energy Analysis Techniques for CUORE

CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of $^{130}$Te. CUORE is also suitable to search for low energy rare events such as solar axions or WIMP scattering, thanks to its ultra-low background and large target mass. However, to conduct such sensitive searches requires improving the energy threshold to 10 keV. In this paper, we describe the analysis techniques developed for the low energy analysis of CUORE-like detectors, using the data acquired from November 2013 to March 2015 by CUORE-0, a single-tower prototype designed to validate the assembly procedure and new cleaning techniques of CUORE. We explain the energy threshold optimization, continuous monitoring of the trigger efficiency, data and event selection, and energy calibration at low energies in detail. We also present the low energy background spectrum of CUORE-0 below 60keV. Finally, we report the sensitivity of CUORE to WIMP annual modulation using the CUORE-0 energy threshold and background, as well as an estimate of the uncertainty on the nuclear quenching factor from nuclear recoils in CUORE-0.

physics.ins-det↗

Sub-structure and merger detection in resolved NIKA Sunyaev-Zel'dovich images of distant clusters

Sub-structures in the hot gas of galaxy clusters are related to their formation history and to the astrophysical processes at play in the intracluster medium (ICM). The thermal Sunyaev-Zel'dovich (tSZ) effect is directly sensitive to the line-of-sight integrated ICM pressure, and is thus particularly adapted to study ICM sub-structures. We apply structure-enhancement filtering algorithms to high resolution tSZ observations of distant clusters, in order to search for pressure discontinuities, compressions, as well as secondary peaks in the ICM. The same filters are applied to synthetic tSZ images extracted from RHAPSODY-G hydrodynamic simulations, in order to better interpret the extracted features. We also study the noise propagation trough the filters and quantify the impact of systematic effects, point source residuals being identified as the dominant potential contaminant. In 3 of our 6 NIKA clusters we identify features at high S/N that show clear evidence for merger events. In MACSJ0717 (z=0.55), three strong pressure gradients are observed on the E, SE and W sectors, and two main peaks in the pressure distribution are identified. We observe a lack of tSZ compact structure in the cool-core cluster PSZ1G045.85 (z=0.61), and a tSZ gradient ridge dominates in the SE. In the highest z cluster, CLJ1227 (z=0.89), we detect a ~45" (360 kpc) long ridge pressure gradient associated with a secondary pressure peak in the W region. Our results show that current tSZ facilities have now reached the angular resolution and sensitivity to allow an exploration of the details of pressure sub-structures in clusters, even at high z. This opens the possibility to quantify the impact of the dynamical state on the relation between the tSZ signal and the mass of clusters, which is important when using tSZ clusters to test cosmological models. This work also marks the first NIKA cluster sample data release.

astro-ph.CO↗

Development of Thermal Kinetic Inductance Detectors suitable for X-ray spectroscopy

We report on the development of Thermal Kinetic Inductance Detectors (TKIDs) suitable to perform X-ray spectroscopy measurements. The aim is to implement MKIDs sensors working in thermal quasi-equilibrium mode to detect X-ray photons as pure calorimeters. The thermal mode is a variation on the MKID classical way of operation that has generated interest in recent years. TKIDs can offer the MKIDs inherent multiplexibility in the frequency domain, a high spatial resolution comparable with CCDs, and an energy resolution theoretically limited only by thermodynamic fluctuations across the thermal weak links. Microresonators are built in Ti/TiN multilayer technology with the inductive part thermally coupled with a metal absorber on a suspended SiN membrane, to avoid escape of phonons from the film to the substrate. The mid-term goal is to optimize the single pixel design in term of superconducting critical temperatures, internal quality factors, kinetic inductance and spectral energy resolution. The final goal is to realize a demonstrator array for a next generation thousand pixels X-ray spectrometer. In this contribution, the status of the project after one year of developments is reported, with detailed reference to the microresonators design and simulations and to the fabrication process.

physics.ins-det↗

Search for Neutrinoless $β^{+}\hspace{-0.2em}EC$ Decay of $^{120}$Te with CUORE-0

We have performed a search for neutrinoless $β^{+}\hspace{-0.2em}EC$ decay of $^{120}$Te using the final CUORE-0 data release. We describe a new analysis method for the simultaneous fit of signatures with different event topology, and of data subsets with different signal efficiency, obtaining a limit on the half-life of the decay of $T_{1/2}>1.6\cdot10^{21}$ yr at $90\%$ CI. Combining this with results from Cuoricino, a predecessor experiment, we obtain the strongest limit to date, corresponding to $T_{1/2}>2.7\cdot10^{21}$ yr at $90\%$ CI.

nucl-ex↗

The projected background for the CUORE experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is designed to search for neutrinoless double beta decay of 130Te with an array of 988 TeO2 bolometers operating at temperatures around 10 mK. The experiment is currently being commissioned in Hall A of Laboratori Nazionali del Gran Sasso, Italy. The goal of CUORE is to reach a 90\% C.L. exclusion sensitivity on the \tect decay half-life of 9$\times$10$^{25}$ years after 5\,years of data taking. The main issue to be addressed to accomplish this aim is the rate of background events in the region of interest, which must not be higher than 10$^{-2}$\,counts/keV/kg/y. We developed a detailed Monte Carlo simulation, based on results from a campaign of material screening, radioassays, and bolometric measurements, to evaluate the expected background. This was used over the years to guide the construction strategies of the experiment and we use it here to project a background model for CUORE. In this paper we report the results of our study and our expectations for the background rate in the energy region where the peak signature of neutrinoless double beta decay of 130Te is expected.

physics.ins-det↗

CUORE Sensitivity to $0νββ$ Decay

We report a study of the CUORE sensitivity to neutrinoless double beta ($0νββ$) decay. We used a Bayesian analysis based on a toy Monte Carlo (MC) approach to extract the exclusion sensitivity to the $0νββ$ decay half-life ($T_{1/2}^{0ν}$) at $90\%$ credibility interval (CI) -- i.e. the interval containing the true value of $T_{1/2}^{0ν}$ with $90\%$ probability -- and the $3 σ$ discovery sensitivity. We consider various background levels and energy resolutions, and describe the influence of the data division in subsets with different background levels. If the background level and the energy resolution meet the expectation, CUORE will reach a $90\%$ CI exclusion sensitivity of $2\cdot10^{25}$ yr with $3$ months, and $9\cdot10^{25}$ yr with $5$ years of live time. Under the same conditions, the discovery sensitivity after $3$ months and $5$ years will be $7\cdot10^{24}$ yr and $4\cdot10^{25}$ yr, respectively.

physics.ins-det↗

Mapping the hot gas temperature in galaxy clusters using X-ray and Sunyaev-Zel'dovich imaging

We propose a method to map the temperature distribution of the hot gas in galaxy clusters that uses resolved images of the thermal Sunyaev-Zel'dovich (tSZ) effect in combination with X-ray data. Application to images from the New IRAM KIDs Array (NIKA) and XMM-Newton allows us to measure and determine the spatial distribution of the gas temperature in the merging cluster MACS J0717.5+3745, at $z=0.55$. Despite the complexity of the target object, we find a good morphological agreement between the temperature maps derived from X-ray spectroscopy only -- using XMM-Newton ($T_{\rm XMM}$) and Chandra ($T_{\rm CXO}$) -- and the new gas-mass-weighted tSZ+X-ray imaging method ($T_{\rm SZ}$). We correlate the temperatures from tSZ+X-ray imaging and those from X-ray spectroscopy alone and find that $T_{\rm SZ}$ is higher than $T_{\rm XMM}$ and lower than $T_{\rm CXO}$ by $\sim 10\%$ in both cases. Our results are limited by uncertainties in the geometry of the cluster gas, contamination from kinetic SZ ($\sim 10\%$), and the absolute calibration of the tSZ map ($7\%$). Investigation using a larger sample of clusters would help minimise these effects.

astro-ph.CO↗

Probing changes of dust properties along a chain of solar-type prestellar and protostellar cores in Taurus with NIKA

The characterization of dust properties in the interstellar medium (ISM) is key for star formation. Mass estimates are crucial to determine gravitational collapse conditions for the birth of new stellar objects in molecular clouds. However, most of these estimates rely on dust models that need further observational constraints from clouds to prestellar and protostellar cores. We present results of a study of dust emissivity changes based on mm-continuum data obtained with the NIKA camera at the IRAM-30m telescope. Observing dust emission at 1.15 mm and 2 mm allows us to constrain the dust emissivity index ($β$) in the Rayleigh-Jeans tail of the dust spectral energy distribution (SED) far from its peak emission, where the contribution of other parameters (i.e. dust temperature) is important. Focusing on the Taurus molecular cloud, a low-mass star-forming regions in the Gould Belt, we analyze the emission properties of several distinct objects in the B213 filament: three prestellar cores, two Class-0/I protostellar cores and one Class-II object. By means of the ratio of the two NIKA channel-maps, we show that in the Rayleigh-Jeans approximation the dust emissivity index varies among the objects. For one prestellar and two protostellar cores, we produce a robust study using Herschel data to constrain the dust temperature of the sources. By using the Abel transform inversion technique we get accurate radial $β$ profiles. We find systematic spatial variations of $β$ in the protostellar cores that is not observed in the prestellar core. While in the former case $β$ decreases toward the center, in the latter it remains constant. Moreover, $β$ appears anticorrelated with the dust temperature. We discuss the implication of these results in terms of dust grain evolution between pre- and protostellar cores.

astro-ph.GA↗

High-sensitivity Kinetic Inductance Detectors for CALDER

Providing a background discrimination tool is crucial for enhancing the sensitivity of next-generation experiments searching for neutrinoless double- beta decay. The development of high-sensitivity (< 20 eV RMS) cryogenic light detectors allows simultaneous read-out of the light and heat signals and enables background suppression through particle identification. The Cryogenic wide- Area Light Detector with Excellent Resolution (CALDER) R&D already proved the potential of this technique using the phonon-mediated Kinetic Inductance Detectors (KIDs) approach. The first array prototype with 4 Aluminum KIDs on a 2 $\times$ 2 cm2 Silicon substrate showed a baseline resolution of 154 $\pm$ 7 eV RMS. Improving the design and the readout of the resonator, the next CALDER prototype featured an energy resolution of 82 $\pm$ 4 eV, by sampling the same substrate with a single Aluminum KID.

physics.ins-det↗

Measurement of the Two-Neutrino Double Beta Decay Half-life of $^{130}$Te with the CUORE-0 Experiment

We report on the measurement of the two-neutrino double beta decay half-life of $^{130}$Te with the CUORE-0 detector. From an exposure of 33.4 kg$\cdot$y of TeO$_2$, the half-life is determined to be $T_{1/2}^{2ν}$ = [8.2 $\pm$ 0.2 (stat.) $\pm$ 0.6 (syst.)] $\times$ 10$^{20}$y. This result is obtained after a detailed reconstruction of the sources responsible for the CUORE-0 counting rate, with a specific study of those contributing to the $^{130}$Te neutrinoless double beta decay region of interest.

nucl-ex↗

High sensitivity phonon-mediated kinetic inductance detector with combined amplitude and phase read-out

The development of wide-area cryogenic light detectors with good energy resolution is one of the priorities of next generation bolometric experiments searching for rare interactions, as the simultaneous read-out of the light and heat signals enables background suppression through particle identification. Among the proposed technological approaches for the phonon sensor, the naturally-multiplexed Kinetic Inductance Detectors (KIDs) stand out for their excellent intrinsic energy resolution and reproducibility. To satisfy the large surface requirement (several cm$^2$) KIDs are deposited on an insulating substrate that converts the impinging photons into phonons. A fraction of phonons is absorbed by the KID, producing a signal proportional to the energy of the original photons. The potential of this technique was proved by the CALDER project, that reached a baseline resolution of 154$\pm$7 eV RMS by sampling a 2$\times$2 cm$^2$ Silicon substrate with 4 Aluminum KIDs. In this paper we present a prototype of Aluminum KID with improved geometry and quality factor. The design improvement, as well as the combined analysis of amplitude and phase signals, allowed to reach a baseline resolution of 82$\pm$4 eV by sampling the same substrate with a single Aluminum KID.

physics.ins-det↗