SearcharxivSearch

arXiv subjects

A. Dabrowski

Publications and source records attributed to A. Dabrowski.

9 recordsLinked to original sources

Electronics design and testing of the CMS Fast Beam Condition Monitor for HL-LHC

The high-luminosity upgrade of the LHC (HL-LHC) brings unprecedented requirements for precision bunch-by-bunch luminosity measurement and beam-induced background monitoring in real time. A key component of the CMS Beam Radiation Instrumentation and Luminosity detector system is a stand-alone luminometer, the Fast Beam Condition Monitor (FBCM), which is able to operate independently at all times with a triggerless asynchronous readout. FBCM utilizes a dedicated front-end ASIC to amplify the signals from CO$_2$-cooled silicon-pad sensors with 1 ns timing resolution. Front-end (FE) electronics are subject to high-radiation conditions, thus all components are radiation hardened: sensors, ASICs, transceivers, etc. The FBCM ASIC contains 6 channels, each outputting a high-speed binary signal carrying the time-of-arrival and time-over-threshold information. This signal is sent via a gigabit optical link to the back-end electronics for analysis. A dedicated test system is designed for the FBCM FE electronics with a modular setup for all testing needs of the project from initial ASIC validation test to system-level testing with the full read-out chain. The paper reports on the design, read-out architecture, and testing program for the FBCM electronics.

physics.ins-det

The CMS Fast Beam Condition Monitor for HL-LHC

The high-luminosity upgrade of the LHC brings unprecedented requirements for real-time and precision bunch-by-bunch online luminosity measurement and beam-induced background monitoring. A key component of the CMS Beam Radiation, Instrumentation and Luminosity system is a stand-alone luminometer, the Fast Beam Condition Monitor (FBCM), which is fully independent from the CMS central trigger and data acquisition services and able to operate at all times with a triggerless readout. FBCM utilizes a dedicated front-end application-specific integrated circuit (ASIC) to amplify the signals from CO$_2$-cooled silicon-pad sensors with a timing resolution of a few nanoseconds, which enables the measurement of the beam-induced background. FBCM uses a modular design with two half-disks of twelve modules at each end of CMS, with four service modules placed close to the outer edge to reduce radiation-induced aging. The electronics system design adapts several components from the CMS Tracker for power, control and read-out functionalities. The dedicated FBCM23 ASIC contains six channels and adjustable shaping time to optimize the noise with regards to sensor leakage current. Each ASIC channel outputs a single binary high-speed asynchronous signal carrying time-of-arrival and time-over-threshold information. The chip output signal is digitized, encoded and sent via a radiation-hard gigabit transceiver and an optical link to the back-end electronics for analysis. This paper reports on the updated design of the FBCM detector and the ongoing testing program.

physics.ins-det

First observation and study of the $K^{\pm} \rightarrow \pi^{0} \pi^{0} \mu^{\pm} \nu$ decay

The NA48/2 experiment at CERN reports the first observation of the $K^{\pm} \rightarrow \pi^{0} \pi^{0} \mu^{\pm} \nu$ decay based on a sample of 2437 candidates with 15% background contamination collected in 2003--2004. The decay branching ratio in the kinematic region of the squared dilepton mass above $0.03$~GeV$^2/c^4$ is measured to be $(0.65 \pm 0.03) \times 10^{-6}$. The extrapolation to the full kinematic space, using a specific model, is found to be $(3.45 \pm 0.16) \times 10^{-6}$, in agreement with chiral perturbation theory predictions.

hep-ex

Recent Results from Polycrystalline CVD Diamond Detectors

Diamond is a material in use at many nuclear and high energy facilities due to its inherent radiation tolerance and ease of use. We have characterized detectors based on chemical vapor deposition (CVD) diamond before and after proton irradiation. We present preliminary results of the spatial resolution of unirradiated and irradiated CVD diamond strip sensors. In addition, we measured the pulse height versus particle rate of unirradiated and irradiated polycrystalline CVD (pCVD) diamond pad detectors up to a particle flux of $20\,\mathrm{MHz/cm^2}$ and a fluence up to $4 \times 10^{15}\,n/\mathrm{cm^2}$.

physics.ins-det

ChPT tests at the NA48 and NA62 experiments at CERN

The NA48/2 Collaboration at CERN has accumulated unprecedented statistics of rare kaon decays in the Ke4 modes: Ke4(+-) ($K^\pm \to π^+ π^- e^\pm ν$) and Ke4(00) ($K^\pm \to π^0 π^0 e^\pm ν$) with nearly one percent background contamination. The detailed study of form factors and branching rates, based on these data, has been completed recently. The results brings new inputs to low energy strong interactions description and tests of Chiral Perturbation Theory (ChPT) and lattice QCD calculations. In particular, new data support the ChPT prediction for a cusp in the $π^0π^0$ invariant mass spectrum at the two charged pions threshold for Ke4(00) decay. New final results from an analysis of about 400 $K^\pm \to π^\pm γγ$ rare decay candidates collected by the NA48/2 and NA62 experiments at CERN during low intensity runs with minimum bias trigger configurations are presented. The results include a model-independent decay rate measurement and fits to ChPT description.

hep-ex

Operation and performance of the ICARUS-T600 cryogenic plant at Gran Sasso underground Laboratory

ICARUS T600 liquid argon time projection chamber is the first large mass electronic detector of a new generation able to combine the imaging capabilities of the old bubble chambers with the excellent calorimetric energy measurement. After the three months demonstration run on surface in Pavia during 2001, the T600 cryogenic plant was significantly revised, in terms of reliability and safety, in view of its long-term operation in an underground environment. The T600 detector was activated in Hall B of the INFN Gran Sasso Laboratory during Spring 2010, where it was operated without interruption for about three years, taking data exposed to the CERN to Gran Sasso long baseline neutrino beam and cosmic rays. In this paper the T600 cryogenic plant is described in detail together with the commissioning procedures that lead to the successful operation of the detector shortly after the end of the filling with liquid Argon. Overall plant performance and stability during the long-term underground operation are discussed. Finally, the decommissioning procedures, carried out about six months after the end of the CNGS neutrino beam operation, are reported.

physics.ins-det

Recent NA48/2 and NA62 results

The NA48/2 Collaboration at CERN has accumulated and analysed unprecedented statistics of rare kaon decays in the $K_{e4}$ modes: $K_{e4}(+-)$ ($K^\pm \to π^+ π^- e^\pm ν$) and $K_{e4}(00)$ ($K^\pm \to π^0 π^0 e^\pm ν$) with nearly one percent background contamination. It leads to the improved measurement of branching fractions and detailed form factor studies. New final results from the analysis of 381 $K^\pm \to π^\pm γγ$ rare decay candidates collected by the NA48/2 and NA62 experiments at CERN are presented. The results include a decay rate measurement and fits to Chiral Perturbation Theory (ChPT) description.

hep-ex

Measurement of the branching ratio of the decay $Ξ^{0}\rightarrow Σ^{+} μ^{-} \barν_μ$

From the 2002 data taking with a neutral kaon beam extracted from the CERN-SPS, the NA48/1 experiment observed 97 $Ξ^{0}\rightarrow Σ^{+} μ^{-} \barν_μ$ candidates with a background contamination of $30.8 \pm 4.2$ events. From this sample, the BR($Ξ^{0}\rightarrow Σ^{+} μ^{-} \barν_μ$) is measured to be $(2.17 \pm 0.32_{\mathrm{stat}}\pm 0.17_{\mathrm{syst}})\times10^{-6}$.

hep-ex

Empirical parameterization of the K+- -> pi+- pi0 pi0 decay Dalitz plot

As first observed by the NA48/2 experiment at the CERN SPS, the $\p0p0$ invariant mass (M00) distribution from $\kcnn$ decay shows a cusp-like anomaly at M00=2m+, where m+ is the charged pion mass. An analysis to extract the pi pi scattering lengths in the isospin I=0 and I=2 states, a0 and a2, respectively, has been recently reported. In the present work the Dalitz plot of this decay is fitted to a new empirical parameterization suitable for practical purposes, such as Monte Carlo simulations of K+- -> pi+- pi0 pi0 decays.

hep-ex