SearcharxivSearch

arXiv subjects

A. Datwyler

Publications and source records attributed to A. Datwyler.

4 recordsLinked to original sources

Sensitivity of the SHiP experiment to dark photons decaying to a pair of charged particles

Dark photons are hypothetical massive vector particles that could mix with ordinary photons. The simplest theoretical model is fully characterised by only two parameters: the mass of the dark photon m$_{\gamma^{\mathrm{D}}}$ and its mixing parameter with the photon, $\varepsilon$. The sensitivity of the SHiP detector is reviewed for dark photons in the mass range between 0.002 and 10 GeV. Different production mechanisms are simulated, with the dark photons decaying to pairs of visible fermions, including both leptons and quarks. Exclusion contours are presented and compared with those of past experiments. The SHiP detector is expected to have a unique sensitivity for m$_{\gamma^{\mathrm{D}}}$ ranging between 0.8 and 3.3$^{+0.2}_{-0.5}$ GeV, and $\varepsilon^2$ ranging between $10^{-11}$ and $10^{-17}$.

hep-ex

SND@LHC

We propose to build and operate a detector that, for the first time, will measure the process $pp\to\nu X$ at the LHC and search for feebly interacting particles (FIPs) in an unexplored domain. The TI18 tunnel has been identified as a suitable site to perform these measurements due to very low machine-induced background. The detector will be off-axis with respect to the ATLAS interaction point (IP1) and, given the pseudo-rapidity range accessible, the corresponding neutrinos will mostly come from charm decays: the proposed experiment will thus make the first test of the heavy flavour production in a pseudo-rapidity range that is not accessible by the current LHC detectors. In order to efficiently reconstruct neutrino interactions and identify their flavour, the detector will combine in the target region nuclear emulsion technology with scintillating fibre tracking layers and it will adopt a muon identification system based on scintillating bars that will also play the role of a hadronic calorimeter. The time of flight measurement will be achieved thanks to a dedicated timing detector. The detector will be a small-scale prototype of the scattering and neutrino detector (SND) of the SHiP experiment: the operation of this detector will provide an important test of the neutrino reconstruction in a high occupancy environment.

physics.ins-det

Plastic scintillator detector with the readout based on an array of large-area SiPMs for the ND280/T2K upgrade and SHiP experiments

Plastic scintillator detectors have been extensively used in particle physics experiments for decades. A large-scale detector is typically arranged as an array of staggered long bars which provide a fast trigger signal and/or particle identification via time-of-flight measurements. Scintillation light is collected by photosensors coupled to both ends of every bar. In this article, we present our study on a direct replacement of commonly used vacuum photomultiplier tubes (PMTs) by arrays of large-area silicon photomultipliers (SiPMs). An SiPM array which is directly coupled to the scintillator bulk, has a clear advantage with respect to a PMT: compactness, mechanical robustness, high PDE, low operation voltage, insensitivity to magnetic field, low material budget, possibility to omit light-guides. In this study, arrays of eight 6 x 6 mm2 area SiPMs were coupled to the ends of plastic scintillator bars with 1.68 m and 2.3 m lengths. An 8 channel SiPM anode readout ASIC (eMUSIC) was used for the readout, amplification and summation of signals of individual SiPMs. Timing characteristics of a large-scale detector prototype were studied in test-beams at the CERN PS. This technology is proposed for the ToF system of the ND280/T2K II upgrade at J-PARC and the timing detector of the SHiP experiment at the CERN SPS.

physics.ins-det

Application of large area SiPMs for the readout of a plastic scintillator based timing detector

In this study an array of eight 6 mm x 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm x 6 cm x 1 cm and 120 cm x 11 cm x 2.5 cm have been studied. An 8-channel SiPM anode readout ASIC (MUSIC R1) based on a novel low input impedance current conveyor has been used to read out and amplify SiPMs independently and sum the signals at the end. Prospects for applications in large-scale particle physics detectors with timing resolution below 100 ps are provided in light of the results.

physics.ins-det