Searcharxiv⌕ Search

arXiv subjects

A. Deisting

Publications and source records attributed to A. Deisting.

31 records · Page 2Linked to original sources

First Search for Light Dark Matter in the Neutrino Fog with XENONnT

We search for dark matter (DM) with a mass [3,12] $\mathrm{GeV} / c^2$ using an exposure of 3.51 $\mathrm{t} \times \mathrm{y}$ with the XENONnT experiment.We consider spin-independent DM-nucleon interactions mediated by a heavy or light mediator, spin-dependent DM-neutron interactions, momentum-dependent DM scattering, and mirror DM. Using a lowered energy threshold compared to the previous WIMP search, a blind analysis of [0.5, 5.0] $\mathrm{keV}$ nuclear recoil events reveals no significant signal excess over the background. XENONnT excludes spin-independent DM-nucleon cross sections $>2.5 \times 10^{-45} \mathrm{~cm}^2$ at $90 \%$ confidence level for 6 $\mathrm{GeV} / c^2$ DM. In the considered mass range, the DM sensitivity approaches the 'neutrino fog', the limitation where neutrinos produce a signal that is indistinguishable from that of light DM-xenon nucleus scattering.

hep-ex↗

The neutron veto of the XENONnT experiment: Results with demineralized water

Radiogenic neutrons emitted by detector materials are one of the most challenging backgrounds for the direct search of dark matter in the form of weakly interacting massive particles (WIMPs). To mitigate this background, the XENONnT experiment is equipped with a novel gadolinium-doped water Cherenkov detector, which encloses the xenon dual-phase time projection chamber (TPC). The neutron veto (NV) tags neutrons via their capture on gadolinium or hydrogen, which release $γ$-rays that are subsequently detected as Cherenkov light. In this work, we present the key features and the first results of the XENONnT NV when operated with demineralized water in the initial phase of the experiment. Its efficiency for detecting neutrons is $(82\pm 1)\,\%$, the highest neutron detection efficiency achieved in a water Cherenkov detector. This enables a high efficiency of $(53\pm 3)\,\%$ for the tagging of WIMP-like neutron signals, inside a tagging time window of $250\,\mathrm{μs}$ between TPC and NV, leading to a livetime loss of $1.6\,\%$ during the first science run of XENONnT.

physics.ins-det↗

First Indication of Solar $^8$B Neutrinos via Coherent Elastic Neutrino-Nucleus Scattering with XENONnT

We present the first measurement of nuclear recoils from solar $^8$B neutrinos via coherent elastic neutrino-nucleus scattering with the XENONnT dark matter experiment. The central detector of XENONnT is a low-background, two-phase time projection chamber with a 5.9 t sensitive liquid xenon target. A blind analysis with an exposure of 3.51 t$\times$yr resulted in 37 observed events above 0.5 keV, with ($26.4^{+1.4}_{-1.3}$) events expected from backgrounds. The background-only hypothesis is rejected with a statistical significance of 2.73 $σ$. The measured $^8$B solar neutrino flux of $(4.7_{-2.3}^{+3.6})\times 10^6 \mathrm{cm}^{-2}\mathrm{s}^{-1}$ is consistent with results from the Sudbury Neutrino Observatory. The measured neutrino flux-weighted CE$ν$NS cross section on Xe of $(1.1^{+0.8}_{-0.5})\times10^{-39} \mathrm{cm}^2$ is consistent with the Standard Model prediction. This is the first direct measurement of nuclear recoils from solar neutrinos with a dark matter detector.

hep-ex↗

XENONnT Analysis: Signal Reconstruction, Calibration and Event Selection

The XENONnT experiment, located at the INFN Laboratori Nazionali del Gran Sasso, Italy, features a 5.9 tonne liquid xenon time projection chamber surrounded by an instrumented neutron veto, all of which is housed within a muon veto water tank. Due to extensive shielding and advanced purification to mitigate natural radioactivity, an exceptionally low background level of (15.8 $\pm$ 1.3) events/(tonne$\cdot$year$\cdot$keV) in the (1, 30) keV region is reached in the inner part of the TPC. XENONnT is thus sensitive to a wide range of rare phenomena related to Dark Matter and Neutrino interactions, both within and beyond the Standard Model of particle physics, with a focus on the direct detection of Dark Matter in the form of weakly interacting massive particles (WIMPs). From May 2021 to December 2021, XENONnT accumulated data in rare-event search mode with a total exposure of one tonne $\cdot$ year. This paper provides a detailed description of the signal reconstruction methods, event selection procedure, and detector response calibration, as well as an overview of the detector performance in this time frame. This work establishes the foundational framework for the `blind analysis' methodology we are using when reporting XENONnT physics results.

hep-ex↗

Cosmogenic background simulations for the DARWIN observatory at different underground locations

Xenon dual-phase time projections chambers (TPCs) have proven to be a successful technology in studying physical phenomena that require low-background conditions. With 40t of liquid xenon (LXe) in the TPC baseline design, DARWIN will have a high sensitivity for the detection of particle dark matter, neutrinoless double beta decay ($0νββ$), and axion-like particles (ALPs). Although cosmic muons are a source of background that cannot be entirely eliminated, they may be greatly diminished by placing the detector deep underground. In this study, we used Monte Carlo simulations to model the cosmogenic background expected for the DARWIN observatory at four underground laboratories: Laboratori Nazionali del Gran Sasso (LNGS), Sanford Underground Research Facility (SURF), Laboratoire Souterrain de Modane (LSM) and SNOLAB. We determine the production rates of unstable xenon isotopes and tritium due to muon-included neutron fluxes and muon-induced spallation. These are expected to represent the dominant contributions to cosmogenic backgrounds and thus the most relevant for site selection.

physics.ins-det↗

First operation of an ALICE OROC operated in high pressure Ar-CO$_{2}$ and Ar-CH$_{4}$

New neutrino-nucleus interaction cross-section measurements are required to improve nuclear models sufficiently for future long-baseline neutrino experiments to meet their sensitivity goals. A time projection chamber (TPC) filled with a high-pressure gas is a promising detector to characterise the neutrino sources planned for such experiments. A gas-filled TPC is ideal for measuring low-energy particles as they travel much further in gas than solid or liquid neutrino detectors. Using a high-pressure gas increases the target density, resulting in more neutrino interactions. This paper will examine the suitability of multiwire proportional chambers (MWPCs) taken from the ALICE TPC to be used as the readout chambers of a high-pressure gas TPC. These chambers were previously operated at atmospheric pressure. We tested one such MWPC at up to almost 5 bar absolute (barA) with the UK high-pressure test stand at Royal Holloway, University of London. This paper reports the successful operation of an ALICE TPC outer readout chamber (OROC) at pressures up to 4.8 bar absolute with Ar-CH$_{4}$ mixtures with a CH$_{4}$ content between 2.8% and 5.0%, and so far up to 4 bar absolute with Ar-CO$_{2}$ (90-10). We measured the charge gain of this OROC using signals induced by an $^{55}$Fe source. The largest gain achieved at 4.8 bar was $64\pm2)\cdot10^{3}$ at stable conditions with an anode wire voltage of 2990 V in Ar-CH$_{4}$ (95.9-4.1). In Ar-CO$_{2}$ a gain of $(4.2\pm0.1)\cdot10^{3}$ was observed at an anode voltage of 2975 V at 4 barA gas pressure. Based on all our gain measurements, we extrapolate that, at the 10 barA pressure necessary to fit 1 tonne of gas into the ALICE TPC volume, a gain of 5000 in Ar-CO$_{2}$ (90-10) (10000 in Ar-CH$_{4}$ with $\sim\!$ 4% CH$_{4}$ content) may be achieved with an OROC anode voltage of 4.2 V ($\sim\!$ 3.1 kV).

physics.ins-det↗

Volume reduction of water samples to increase sensitivity for radioassay of lead contamination

The World Health Organisation (WHO) presents an upper limit for lead in drinking water of 10 parts per billion ppb. Typically, to reach this level of sensitivity, expensive metrology is required. To increase the sensitivity of low cost devices, this paper explores the prospects of using a volume reduction technique of a boiled water sample doped with Lead-210 ($^{210}Pb$), as a means to increase the solute's concentration. $^{210}$Pb is a radioactive lead isotope and its concentration in a water sample can be measured with e.g. High Purity Germanium (HPGe) detectors at the Boulby Underground Germanium Suite. Concentrations close to the WHO limit have not been examined. This paper presents a measurement of the volume reduction technique retaining $99\pm(9)\%$ of $^{210}$Pb starting from a concentration of $1.9\times10^{-6}$ ppb before reduction and resulting in $2.63\times10^{-4}$ ppb after reduction. This work also applies the volume reduction technique to London tap water and reports the radioassay results from gamma counting in HPGe detectors. Among other radio-isotopes, $^{40}$K, $^{210}$Pb, $^{131}$I and $^{177}$Lu were identified at measured concentrations of $2.83\times10^{3}$ ppb, $2.55\times10^{-7}$ ppb, $5.06\times10^{-10}$ ppb and $5.84\times10^{-10}$ ppb in the London tap water sample. This technique retained $90\pm50\%$ of $^{40}$K. Stable lead was inferred from the same water sample at a measured concentration of 0.012 ppb, prior to reduction.

physics.ins-det↗

PlomBOX -- development of a low-cost CMOS device for environmental monitoring

This paper reports on the development of a novel CMOS device employing lead-sensing bacteria to assay lead in drinking water. The objective of the PlomBOX project is to develop a low-cost sensor (£10) which can expedite access to on-demand assay methods and thus help mitigate lead intake through contaminated drinking water. The project follows three development paths: a) Certain bacteria can fluoresce or change colour when in the presence of lead. A genetically modified strain of Escherichia coli sensitive to lead concentrations up to 10 ppb is being developed. This constitutes the biosensor that fluoresces in proportion to the presence of lead. b) Bacteria response is imaged using a microprocessor (ESP32) with a camera module. This constitutes the optical metrology component of the PlomBOX. c) Data acquisition and control of the PlomBOX is achieved through a Bluetooth connection with the PlomApp, a custom-developed mobile phone application. Data are sent from the PlomApp to a database where a bespoke automated analysis software provides a result of the lead concentration in a sample of water. This paper reports on the instrumentation challenges of developing the electronics for the PlomBOX and on the first prototype.

physics.ins-det↗

The upgrade of the ALICE TPC with GEMs and continuous readout

The upgrade of the ALICE TPC will allow the experiment to cope with the high interaction rates foreseen for the forthcoming Run 3 and Run 4 at the CERN LHC. In this article, we describe the design of new readout chambers and front-end electronics, which are driven by the goals of the experiment. Gas Electron Multiplier (GEM) detectors arranged in stacks containing four GEMs each, and continuous readout electronics based on the SAMPA chip, an ALICE development, are replacing the previous elements. The construction of these new elements, together with their associated quality control procedures, is explained in detail. Finally, the readout chamber and front-end electronics cards replacement, together with the commissioning of the detector prior to installation in the experimental cavern, are presented. After a nine-year period of R&D, construction, and assembly, the upgrade of the TPC was completed in 2020.

physics.ins-det↗

Characterization of Germanium Detectors for the First Underground Laboratory in Mexico

This article reports the characterization of two High Purity Germanium detectors performed by extracting and comparing their efficiencies using experimental data and Monte Carlo simulations. The efficiencies were calculated for pointlike $γ$-ray sources as well as for extended calibration sources. Characteristics of the detectors such as energy linearity, energy resolution, and full energy peak efficiencies are reported from measurements performed on surface laboratories. The detectors will be deployed in a $γ$-ray assay facility that will be located in the first underground laboratory in Mexico, Laboratorio Subterráneo de Mineral del Chico (LABChico), in the Comarca Minera UNESCO Global Geopark

physics.ins-det↗

Off-Axis Characterisation of the CERN T10 Beam for low Momentum Proton Measurements with a High Pressure Gas Time Projection Chamber

We present studies of proton fluxes in the T10 beamline at CERN. A prototype high pressure gas time projection chamber (TPC) was exposed to the beam of protons and other particles, using the 0.8 GeV/c momentum setting in T10, in order to make cross section measurements of low energy protons in argon. To explore the energy region comparable to hadrons produced by GeV-scale neutrino interactions at oscillation experiments, i.e., near 0.1 GeV of kinetic energy, methods of moderating the T10 beam were employed: the dual technique of moderating the beam with acrylic blocks and measuring scattered protons off the beam axis was used to decrease the kinetic energy of incident protons, as well as change the proton/minimum ionising particle (MIP) composition of the incident flux. Measurements of the beam properties were made using time of flight systems upstream and downstream of the TPC. The kinetic energy of protons reaching the TPC was successfully changed from $\sim0.3$ GeV without moderator blocks to less than 0.1 GeV with four moderator blocks (40 cm path length). The flux of both protons and MIPs off the beam axis was increased. The ratio of protons to MIPs vary as a function of the off-axis angle allowing for possible optimisation of the detector to select the type of required particles. Simulation informed by the time of flight measurements show that with four moderator blocks placed in the beamline, ($5.6 \pm 0.1$) protons with energies below 0.1 GeV per spill traversed the active TPC region. Measurements of the beam composition and energy are presented.

physics.ins-det↗

Secondary discharge studies in single and multi GEM structures

Secondary discharges, which consist of the breakdown of a gap near a GEM foil upon a primary discharge across that GEM, are studied in this work. Their main characteristics are the occurrence a few $10\,μ\textrm{s}$ after the primary, the relatively sharp onset at moderate electric fields across the gap, the absence of increased fields in the system, and their occurrence under both field directions. They can be mitigated using series resistors in the high-voltage connection to the GEM electrode facing towards an anode. The electric field at which the onset of secondary discharges occurs indeed increases with increasing resistance. Discharge propagation form GEM to GEM in a multi-GEM system affects the occurrence probability of secondary discharges in the gaps between neighbouring GEMs. Furthermore, evidence of charges flowing through the gap after the primary discharge are reported. Such currents may or may not lead to a secondary discharge. A characteristic charge, of the order of $10^{10}\,\textrm{electrons}$, has been measured as the threshold for a primary discharge to be followed by a secondary discharge, and this number slightly depends on the gas composition. A mechanism involving the heating of the cathode surface as trigger for secondary discharges is proposed.

physics.ins-det↗

Particle identification studies with a full-size 4-GEM prototype for the ALICE TPC upgrade

A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an interaction rate of about 50 kHz, which is about a factor of 50 above the present readout rate of the TPC. This will result in a significant improvement on the sensitivity to rare probes that are considered key observables to characterize the QCD matter created in such collisions. In order to make full use of this luminosity, the currently used gated Multi-Wire Proportional Chambers will be replaced. The upgrade relies on continuously operated readout detectors employing Gas Electron Multiplier technology to retain the performance in terms of particle identification via the measurement of the specific energy loss by ionization d$E$/d$x$. A full-size readout chamber prototype was assembled in 2014 featuring a stack of four GEM foils as an amplification stage. The performance of the prototype was evaluated in a test beam campaign at the CERN PS. The d$E$/d$x$ resolution complies with both the performance of the currently operated MWPC-based readout chambers and the challenging requirements of the ALICE TPC upgrade program. Detailed simulations of the readout system are able to reproduce the data.

physics.ins-det↗