SearcharxivSearch

arXiv subjects

A. Di Giovanni

Publications and source records attributed to A. Di Giovanni.

At least 19 recordsLinked to original sources

Measurement of the cosmic ray nickel energy spectrum from 10 GeV/n to 2 TeV/n with the DAMPE

Nickel, one of the most tightly bound nuclei alongside iron, is the most abundant heavy element beyond iron in cosmic rays. With DAMPE's excellent charge resolution and broad energy range, a high-precision energy spectrum provides valuable insights into the acceleration sources of heavy nuclei and their propagation through the interstellar medium. In this analysis, we report the direct measurement of cosmic-ray nickel spectrum from 10 GeV/n to 2 TeV/n with nine years of flight data. The nickel spectrum is consistent with a single power law with spectral index -2.60 +/- 0.03 from 40 GeV/n to 1 TeV/n. This work provides an accurate measurement of differential flux of nickel with kinetic energy extending to TeV/n for the first time.

astro-ph.HE

Observations of the Fermi bubbles and the Galactic center excess with the DArk Matter Particle Explorer

The DArk Matter Particle Explorer (DAMPE) is a space-borne high-energy particle detector that surveys the $γ$-ray sky above$\sim 2~\rm GeV$ with a peak acceptance of $\sim 0.2~\rm m^2\,sr$. With the 102 months of data collected by DAMPE, we show that the Fermi bubbles are detected at a significance of $\sim 26σ$ and identify a GeV excess in the direction of Galactic center at $\sim 7 σ$ confidence. Both spectra and morphology are consistent with those observed by Fermi-LAT and the GeV excess component can be interpreted by the dark matter annihilation with a mass of $\sim 50$ GeV and a velocity-averaged cross section of $\sim 10^{-26}~{\rm cm^{3}~s^{-1}}$ for the $χχ\rightarrow b\bar{b}$ channel. Our results thus provide the first independent detection of these two intriguing diffuse gamma-ray sources besides Fermi-LAT.

astro-ph.HE

Search for Light-Mass Fractionally Charged Particles in Space with DAMPE Experiment

Free Fractionally Charged Particles (FCPs) are predicted by some theories beyond or extended to the standard model. FCPs have been widely searched for by underground and space-based experiments based on the assumption of heavy lepton-like particles. However, there is a paucity of research focusing on light-mass FCPs (LFCPs) in the sub-MeV mass range. In this work, we report the LFCPs in primary high energy cosmic rays, based on observational data from the Dark Matter Particle Explorer (DAMPE) satellite. This study utilized ten years on-orbit data of DAMPE to search for LFCPs with a charge of $\frac{2}{3}~e$. No LFCP candidate was observed. Upper flux limit of LFCPs with a mass of 0.511 MeV$/c^{2}$ and a charge of $\frac{2}{3}~e$ is determined to be $\rm 5.0 \times 10^{-11}\,cm^{-2}sr^{-1}s^{-1}$ at the $\rm 90\%$ confidence level.

astro-ph.HE

Diverse properties of electron Forbush decreases revealed by the Dark Matter Particle Explorer

The Forbush decrease (FD) of cosmic rays is an important probe of the interplanetary environment disturbed by solar activities. In this work, we study the properties of 8 FDs electrons (including positrons) between 2 GeV and 20 GeV from January, 2016 to March, 2024, with the Dark Matter Particle Explorer. The maximum decrease amplitudes of these events are about 30% - 15%, and the amplitudes reduce with energy. The recovery time of these events shows diverse behaviors of their energy-dependence. Some of them show strong energy-dependence, while some have a nearly constant recovery time. It has been shown that such diverse behaviors could be related with the geometry of the disturbed regions of the interplanetary space by coronal mass ejections (CME), represented by the combined effect of the CME velocity, angular spread, and ejection direction.

astro-ph.HE

Performance and radiation damage mitigation strategy for silicon photomultipliers on LEO space missions

Space missions require lightweight, low-power consuming, radiation-tolerant components. Silicon photomultipliers are increasingly used for detecting near-UV, optical, and infrared light in space due to their compact design, low cost, low power consumption, robustness, and high photo-detection efficiency, which makes them sensitive to single photons. Although SiPMs outperform traditional photomultiplier tubes in many areas, concerns about their radiation tolerance and noise remain. In this study, we estimate the radiation effects on a satellite in sun-synchronous low Earth orbit (LEO) at an altitude of 550~km during the declining phase of solar cycle 25 (2026-2029). We evaluated silicon photomultipliers produced by the Foundation Bruno Kessler (FBK) using front-side illuminated technology with metal trenches (NUV-HD-MT), assessing their response to a 50~MeV proton beam and exposure to a $β$-radioactive source (strontium-90). Simulations with SPENVIS and Geant4 were used to validate the experimental results. Based on our findings, we propose a photosensor annealing strategy for space-based instruments.

hep-ex

The simulation chain for the Terzina Cherenkov telescope on board the NUSES space mission

The Terzina telescope is designed to detect ultra-high energy cosmic rays (UHECRs) and Earth-skimming neutrinos from a 550 km low-Earth orbit (LEO) by observing Cherenkov light emitted by Extensive Air Showers (EAS) in the Earth's atmosphere pointing towards the telescope and in the field of view. In this contribution, a simulation chain for the Terzina telescope on board the NUSES mission will be presented. The chain encompasses all stages of the detection process, from event generation and EAS modelling with CORSIKA and EASCherSim to Geant4-based simulations of the telescope's geometry and optics, followed by modelling of the trigger system and silicon photomultiplier (SiPM) response. The Geant4 module includes the real CAD model of the telescope structure and optical components, with aspherical lenses manually implemented to ensure accurate representation of the optical efficiency and point spread function in Geant4. This comprehensive pipeline, developed using modular C++ code and Python tools for event analysis and reconstruction, produces detailed performance assessments of a telescope operating in a LEO mission but can be adapted for any high altitude Cherenkov telescope, making it a versatile tool for future observatory designs. The possibility of modelling balloons in the atmosphere has also been developed.

astro-ph.IM

Investigation of hadronic cross sections of cosmic ray carbon and oxygen on BGO from 200 GeV to 10 TeV energy at the DAMPE experiment

The Dark Matter Particle Explorer (DAMPE) has made significant progress in measuring the fluxes of cosmic rays. These new measurements are pivotal in advancing our understanding of the origins and propagation mechanisms of cosmic rays. The bismuth germanium oxide (BGO) calorimeter plays a crucial role in these measurements, particularly in the precise determination of cosmic ray fluxes. However, for a calorimetric experiment like DAMPE, uncertainties in hadronic models persist as a major barrier in achieving more accurate measurements of fluxes of cosmic ray nuclei. This study centers on the measurement of the inelastic hadronic cross sections of carbon and oxygen nuclei interacting with BGO crystals target over an extensive energy range, spanning from 200 GeV to 10 TeV. For carbon nuclei interacting with the BGO target, the measurements of the cross sections have achieved a total relative uncertainty of less than 10% below 8 TeV for carbon, and below 3 TeV for oxygen. For oxygen nuclei, the same level of precision was attained below 3 TeV. Additionally, we compare the experimental results with Geant4 and FLUKA simulations to validate the accuracy and consistency of these simulation tools. Through comprehensive analysis of the inelastic hadronic interaction cross sections, this research provides validation for the hadronic interaction models used in DAMPE's cosmic-ray flux measurements.

hep-ex

Effective field theory and inelastic dark matter results from XENON1T

In this work, we expand on the XENON1T nuclear recoil searches to study the individual signals of dark matter interactions from operators up to dimension-eight in a Chiral Effective Field Theory (ChEFT) and a model of inelastic dark matter (iDM). We analyze data from two science runs of the XENON1T detector totaling 1\,tonne$\times$year exposure. For these analyses, we extended the region of interest from [4.9, 40.9]$\,$keV$_{\text{NR}}$ to [4.9, 54.4]$\,$keV$_{\text{NR}}$ to enhance our sensitivity for signals that peak at nonzero energies. We show that the data is consistent with the background-only hypothesis, with a small background over-fluctuation observed peaking between 20 and 50$\,$keV$_{\text{NR}}$, resulting in a maximum local discovery significance of 1.7\,$σ$ for the Vector$\otimes$Vector$_{\text{strange}}$ ($VV_s$) ChEFT channel for a dark matter particle of 70$\,$GeV/c$^2$, and $1.8\,σ$ for an iDM particle of 50$\,$GeV/c$^2$ with a mass splitting of 100$\,$keV/c$^2$. For each model, we report 90\,\% confidence level (CL) upper limits. We also report upper limits on three benchmark models of dark matter interaction using ChEFT where we investigate the effect of isospin-breaking interactions. We observe rate-driven cancellations in regions of the isospin-breaking couplings, leading to up to 6 orders of magnitude weaker upper limits with respect to the isospin-conserving case.

hep-ex

Hadronic cross section measurements with the DAMPE space mission using 20GeV-10TeV cosmic-ray protons and $^4$He

Precise direct cosmic-ray (CR) measurements provide an important probe to study the energetic particle sources in our Galaxy, and the interstellar environment through which these particles propagate. Uncertainties on hadronic models, ion-nucleon cross sections in particular, are currently the limiting factor towards obtaining more accurate CR ion flux measurements with calorimetric space-based experiments. We present an energy-dependent measurement of the inelastic cross section of protons and helium-4 nuclei (alpha particles) on a Bi$_4$Ge$_3$O$_{12}$ target, using 88 months of data collected by the DAMPE space mission. The kinetic energy range per nucleon of the measurement points ranges from 18 GeV to 9 TeV for protons, and from 5 GeV/n to 3 TeV/n for helium-4 nuclei. Our results lead to a significant improvement of the CR flux normalisation. In the case of helium-4, these results correspond to the first cross section measurements on a heavy target material at energies above 10 GeV/n.

hep-ex

Observation of a spectral hardening in cosmic ray boron spectrum with the DAMPE space mission

Secondary cosmic ray fluxes are important probes of the propagation and interaction of high-energy particles in the Galaxy. Recent measurements of primary and secondary cosmic ray nuclei have revealed unexpected spectral features that demand a deeper understanding. In this work we report the direct measurement of the cosmic ray boron spectrum from 10 GeV/n to 8 TeV/n with eight years of data collected by the Dark Matter Particle Explorer (DAMPE) mission. The measured spectrum shows an evident hardening at $182\pm24$ GeV/n with a spectral power index of $γ_1 = 3.02 \pm 0.01$ before the break and an index change of $Δγ= 0.31 \pm 0.05$ after the break. A simple power law model is disfavored at a confidence level of 8$σ$. Compared with the hardenings measured in the DAMPE proton and helium spectra, the secondary boron spectrum hardens roughly twice as much as these primaries, which is consistent with a propagation related mechanism to interpret the spectral hardenings of cosmic rays observed at hundreds of GeV/n.

astro-ph.HE

Emission of Single and Few Electrons in XENON1T and Limits on Light Dark Matter

Delayed single- and few-electron emissions plague dual-phase time projection chambers, limiting their potential to search for light-mass dark matter. This paper examines the origins of these events in the XENON1T experiment. Characterization of the intensity of delayed electron backgrounds shows that the resulting emissions are correlated, in time and position, with high-energy events and can effectively be vetoed. In this work we extend previous S2-only analyses down to a single electron. From this analysis, after removing the correlated backgrounds, we observe rates < 30 events/(electron*kg*day) in the region of interest spanning 1 to 5 electrons. We derive 90% confidence upper limits for dark matter-electron scattering, first direct limits on the electric dipole, magnetic dipole, and anapole interactions, and bosonic dark matter models, where we exclude new parameter space for dark photons and solar dark photons.

hep-ex

Measurement of the cosmic p+He energy spectrum from 50 GeV to 0.5 PeV with the DAMPE space mission

Recent observations of the light component of the cosmic-ray spectrum have revealed unexpected features that motivate further and more precise measurements up to the highest energies. The Dark Matter Particle Explorer is a satellite-based cosmic-ray experiment that has been operational since December 2015, continuously collecting data on high-energy cosmic particles with very good statistics, energy resolution, and particle identification capabilities. In this work, the latest measurements of the energy spectrum of proton+helium in the energy range from 46 GeV to 464 TeV are presented. Among the most distinctive features of the spectrum, a spectral hardening at 600 GeV has been observed, along with a softening at 29 TeV measured with a 6.6σ significance. Moreover, the detector features and the analysis approach allowed for the extension of the spectral measurement up to the sub-PeV region. Even if with small statistical significance due to the low number of events, data suggest a new spectral hardening at about 150 TeV.

astro-ph.HE

Optimizing a Broad Energy High Purity Germanium (BEGe) Detector Operated at Shallow Depth in Abu Dhabi

In this work we present the characterization of a Broad Energy Germanium (BEGe) type High Purity Germanium (HPGe) detector, with a carbon fiber entrance window thickness of 0.6 mm and an active area of 6305 mm2, operated at shallow depth (~ 8m) in Abu Dhabi, UAE. A 1.6 keV Full Width Half Maximum (FWHM) was obtained for the 662 keV peak of 137Cs. A muon veto was applied, reducing the background by 8 % (for energies greater than 100 keV). Flushing the volume around the detector endcap with nitrogen gas, to remove radon and thus its progeny, further reduced the background by ~3 %. A thorough analysis for the shaping filter parameters showed that the detector has better resolution at low rise-time values (2 - 5 us) especially for low energy gamma (<600keV), keeping the flattop value fixed at 1.1 us.

physics.ins-det

The Terzina instrument onboard the NUSES space mission

In this paper we will introduce the Terzina instrument, which is one of the two scientific payloads of the NUSES satellite mission. NUSES serves as a technological pathfinder, hosting a suite of innovative instruments designed for the in-orbit detection of cosmic rays, neutrinos, and gamma rays across various energy ranges. The Terzina instrument itself is a compact telescope equipped with Schmidt-Cassegrain optics. Its primary objective is to detect Cherenkov radiation emitted by Extensive Air Showers generated by the interaction of high-energy (> 100 PeV) cosmic rays with the Earth's atmosphere. Terzina represents a critical step forward in the development of future space-based instruments aimed at detecting upward-moving showers induced by tau-leptons and muons resulting from the interaction of high-energy astrophysical neutrinos with the Earth. In this paper, we will delve into the key technical aspects of the Terzina instrument, its capabilities, and its potential for detection.

astro-ph.IM

RAAD: LIGHT-1 CubeSat's Payload for the Detection of Terrestrial Gamma-Ray Flashes

The Rapid Acquisition Atmospheric Detector (RAAD), onboard the LIGHT-1 3U CubeSat, detects photons between hard X-rays and soft gamma-rays, in order to identify and characterize Terrestrial Gamma Ray Flashes (TGFs). Three detector configurations are tested, making use of Cerium Bromide and Lanthanum BromoChloride scintillating crystals coupled to photomultiplier tubes or Multi-Pixel Photon Counters, in order to identify the optimal combination for TGF detection. High timing resolution, a short trigger window, and the short decay time of its electronics allow RAAD to perform accurate measurements of prompt, transient events. Here we describe the overview of the detection concept, the development of the front-end acquisition electronics, as well as the ground testing and simulation the payload underwent prior to its launch on December 21st, 2021. We further present an analysis of the detector's in-orbit system behavior and some preliminary results.

physics.space-ph

Material radiopurity control in the XENONnT experiment

The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and $^{222}$Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove or mitigate surface contamination of detector materials are described. Screening results, used as inputs for a XENONnT Monte Carlo simulation, predict a reduction of materials background ($\sim$17%) with respect to its predecessor XENON1T. Through radon emanation measurements, the expected $^{222}$Rn activity concentration in XENONnT is determined to be 4.2$\,(^{+0.5}_{-0.7})\,μ$Bq/kg, a factor three lower with respect to XENON1T. This radon concentration will be further suppressed by means of the novel radon distillation system.

physics.ins-det

Search for New Physics in Electronic Recoil Data from XENONnT

We report on a blinded analysis of low-energy electronic-recoil data from the first science run of the XENONnT dark matter experiment. Novel subsystems and the increased 5.9 tonne liquid xenon target reduced the background in the (1, 30) keV search region to $(15.8 \pm 1.3)$ events/(tonne$\times$year$\times$keV), the lowest ever achieved in a dark matter detector and $\sim$5 times lower than in XENON1T. With an exposure of 1.16 tonne-years, we observe no excess above background and set stringent new limits on solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter.

hep-ex