Searcharxiv⌕ Search

arXiv subjects

A. Di Lieto

Publications and source records attributed to A. Di Lieto.

9 recordsLinked to original sources

High brightness CW electron beams from Superconducting RF photoemission gun

CW photoinjectors operating at high accelerating gradients promise to revolutionize many areas of science and applications. They can establish the basis for a new generation of monochromatic X-ray free electron lasers, high brightness hadron beams, or a new generation of microchip production. In this letter we report on the record-performing superconducting RF electron gun with $\textrm{CsK}_{2}\textrm{Sb}$ photocathode. The gun is generating high charge electron bunches (up to 10 nC/bunch) and low transverse emittances, while operating for months with a single photocathode. This achievement opens a new era in generating high-power beams with a very high average brightness.

physics.acc-ph↗

Laser induced fluorescence for axion dark matter detection: a feasibility study in YLiF$_4$:Er$^{3+}$

We present a detection scheme to search for QCD axion dark matter, that is based on a direct interaction between axions and electrons explicitly predicted by DFSZ axion models. The local axion dark matter field shall drive transitions between Zeeman-split atomic levels separated by the axion rest mass energy $m_a c^2$. Axion-related excitations are then detected with an upconversion scheme involving a pump laser that converts the absorbed axion energy ($\sim $ hundreds of $μ$eV) to visible or infrared photons, where single photon detection is an established technique. The proposed scheme involves rare-earth ions doped into solid-state crystalline materials, and the optical transitions take place between energy levels of $4f^N$ electron configuration. Beyond discussing theoretical aspects and requirements to achieve a cosmologically relevant sensitivity, especially in terms of spectroscopic material properties, we experimentally investigate backgrounds due to the pump laser at temperatures in the range $1.9-4.2$ K. Our results rule out excitation of the upper Zeeman component of the ground state by laser-related heating effects, and are of some help in optimizing activated material parameters to suppress the multiphonon-assisted Stokes fluorescence.

astro-ph.CO↗

Neutron spectroscopic study of crystal-field excitations and the effect of the crystal field on dipolar magnetism in Li$R$F$_4$ ($R$ = Gd, Ho, Er, Tm, and Yb)

We present a systematic study of the crystal field interactions in the Li$R$F$_4$, $R$ = Gd, Ho, Er, Tm and Yb, family of rare-earth magnets. Using detailed inelastic neutron scattering measurements we have been able to quantify the transition energies and wavefunctions for each system. This allows us to quantitatively describe the high-temperature susceptibility measurements for the series of materials and make predictions based on a mean-field approach for the low-temperature thermal and quantum phase transitions. We show that coupling between crystal field and phonon states leads to lineshape broadening in LiTmF$_4$ and level splitting in LiYbF$_4$. Furthermore, using high resolution neutron scattering from LiHoF$_4$, we find anomalous broadening of crystal-field excitations which we attribute to magnetoelastic coupling.

cond-mat.str-el↗

Particle detection through the quantum counter concept in YAG:Er$^{3+}$

We report about a novel scheme for particle detection based on the infrared quantum counter concept. Its operation consists of a two-step excitation process of a four level system, that can be realized in rare earth-doped crystals when a cw pump laser is tuned to the transition from the second to the fourth level. The incident particle raises the atoms of the active material into a low lying, metastable energy state, triggering the absorption of the pump laser to a higher level. Following a rapid non-radiative decay to a fluorescent level, an optical signal is observed with a conventional detectors. In order to demonstrate the feasibility of such a scheme, we have investigated the emission from the fluorescent level $^4$S$_{3/2}$ (540 nm band) in an Er$^{3+}$-doped YAG crystal pumped by a tunable titanium sapphire laser when it is irradiated with 60 keV electrons delivered by an electron gun. We have obtained a clear signature this excitation increases the $^{4}I_{13/2}$ metastable level population that can efficiently be exploited to generate a detectable optical signal.

physics.ins-det↗

Advanced Virgo: a 2nd generation interferometric gravitational wave detector

Advanced Virgo is the project to upgrade the Virgo interferometric detector of gravitational waves, with the aim of increasing the number of observable galaxies (and thus the detection rate) by three orders of magnitude. The project is now in an advanced construction phase and the assembly and integration will be completed by the end of 2015. Advanced Virgo will be part of a network with the two Advanced LIGO detectors in the US and GEO HF in Germany, with the goal of contributing to the early detections of gravitational waves and to opening a new observation window on the universe. In this paper we describe the main features of the Advanced Virgo detector and outline the status of the construction.

gr-qc↗

Reconstruction of the gravitational wave signal $h(t)$ during the Virgo science runs and independent validation with a photon calibrator

The Virgo detector is a kilometer-scale interferometer for gravitational wave detection located near Pisa (Italy). About 13 months of data were accumulated during four science runs (VSR1, VSR2, VSR3 and VSR4) between May 2007 and September 2011, with increasing sensitivity. In this paper, the method used to reconstruct, in the range 10 Hz-10 kHz, the gravitational wave strain time series $h(t)$ from the detector signals is described. The standard consistency checks of the reconstruction are discussed and used to estimate the systematic uncertainties of the $h(t)$ signal as a function of frequency. Finally, an independent setup, the photon calibrator, is described and used to validate the reconstructed $h(t)$ signal and the associated uncertainties. The uncertainties of the $h(t)$ time series are estimated to be 8% in amplitude. The uncertainty of the phase of $h(t)$ is 50 mrad at 10 Hz with a frequency dependence following a delay of 8 $μ$s at high frequency. A bias lower than $4\,\mathrm{μs}$ and depending on the sky direction of the GW is also present.

gr-qc↗

Characterization of the Virgo Seismic Environment

The Virgo gravitational wave detector is an interferometer (ITF) with 3km arms located in Pisa, Italy. From July to October 2010, Virgo performed its third science run (VSR3) in coincidence with the LIGO detectors. Despite several techniques adopted to isolate the interferometer from the environment, seismic noise remains an important issue for Virgo. Vibrations produced by the detector infrastructure (such as air conditioning units, water chillers/heaters, pumps) are found to affect Virgo's sensitivity, with the main coupling mechanisms being through beam jitter and scattered light processes. The Advanced Virgo (AdV) design seeks to reduce ITF couplings to environmental noise by having most vibration-sensitive components suspended and in-vacuum, as well as muffle and relocate loud machines. During the months of June and July 2010, a Guralp-3TD seismometer was stationed at various locations around the Virgo site hosting major infrastructure machines. Seismic data were examined using spectral and coherence analysis with seismic probes close to the detector. The primary aim of this study was to identify noisy machines which seismically affect the ITF environment and thus require mitigation attention. Analyzed machines are located at various distances from the experimental halls, ranging from 10m to 100m. An attempt is made to measure the attenuation of emitted noise at the ITF and correlate it to the distance from the source and to seismic attenuation models in soil.

gr-qc↗

Calibration and sensitivity of the Virgo detector during its second science run

The Virgo detector is a kilometer-length interferometer for gravitational wave detection located near Pisa (Italy). During its second science run (VSR2) in 2009, six months of data were accumulated with a sensitivity close to its design. In this paper, the methods used to determine the parameters for sensitivity estimation and gravitational wave reconstruction are described. The main quantities to be calibrated are the frequency response of the mirror actuation and the sensing of the output power. Focus is also put on their absolute timing. The monitoring of the calibration data as well as the parameter estimation with independent techniques are discussed to provide an estimation of the calibration uncertainties. Finally, the estimation of the Virgo sensitivity in the frequency-domain is described and typical sensitivities measured during VSR2 are shown.

gr-qc↗

Virgo calibration and reconstruction of the gravitational wave strain during VSR1

Virgo is a kilometer-length interferometer for gravitational waves detection located near Pisa. Its first science run, VSR1, occured from May to October 2007. The aims of the calibration are to measure the detector sensitivity and to reconstruct the time series of the gravitational wave strain h(t). The absolute length calibration is based on an original non-linear reconstruction of the differential arm length variations in free swinging Michelson configurations. It uses the laser wavelength as length standard. This method is used to calibrate the frequency dependent response of the Virgo mirror actuators and derive the detector in-loop response and sensitivity within ~5%. The principle of the strain reconstruction is highlighted and the h(t) systematic errors are estimated. A photon calibrator is used to check the sign of h(t). The reconstructed h(t) during VSR1 is valid from 10 Hz up to 10 kHz with systematic errors estimated to 6% in amplitude. The phase error is estimated to be 70 mrad below 1.9 kHz and 6 micro-seconds above.

gr-qc↗