SearcharxivSearch

arXiv subjects

A. Droster

Publications and source records attributed to A. Droster.

14 recordsLinked to original sources

The Cryogenic System of DMRadio-50L

The DMRadio-50L experiment is designed to search for axion dark matter in the 5 kHz - 5 MHz frequency range using a lumped-element LC resonator and a toroidal magnet and to serve as a testbed for quantum sensors. This paper describes the custom cryogenic system developed to meet the stringent requirements of the experiment within a standard laboratory environment. The system is designed to cool a 200 kg detector assembly to temperatures as low as 50 mK while providing sufficient cooling power at multiple temperature stages. We present the conceptual design, technical implementation, and measured performance of the hybrid cryogenic system, which combines a horizontal dilution refrigerator with a large vertical payload cryostat.

physics.ins-det

DMRadio-Core: A new approach for GUT-scale axion searches

Searches for QCD axions with masses in the neV/$c^2$ mass range are strongly motivated by new physics at the GUT scale and by well-motivated pre-inflationary axion symmetry breaking scales. This parameter space is challenging to probe due to the small axion-photon couplings, which typically require large, high-field magnets with substantial stored energy. In this paper, we propose a new experimental geometry based on a narrow-bore, segmented solenoid that optimizes the collection of the axion-induced signal using LC resonators outside the high-field region of the magnet bore. This alternative optimization significantly reduces the required stored magnetic energy while preserving sensitivity, enabling a near-term experiment in the 30-200 MHz (120-830 neV/$c^2$) range, with a cost-effective, staged scaling to a GUT-scale experiment in the 100 kHz-30 MHz (0.4-120 neV/$c^2$) range.

hep-ex

A First Demonstration of the SQUAT Detector Architecture: Direct Measurement of Resonator-Free Charge-Sensitive Transmons

The Superconducting Quasiparticle-Amplifying Transmon (SQUAT) is a new sensor architecture for THz (meV) detection based on a weakly charge-sensitive transmon directly coupled to a transmission line. In such devices, energy depositions break Cooper pairs in the qubit capacitor islands, generating quasiparticles. Quasiparticles that tunnel across the Josephson junction change the transmon qubit parity, generating a measurable signal. In this paper, we present the design of first-generation SQUATs and demonstrate an architecture validation. We summarize initial characterization measurements made with prototype devices, comment on background sources that influence the observed parity-switching rate, and present experimental results showing simultaneous detection of charge and quasiparticle signals using aluminum-based SQUATs.

physics.ins-det

Search for Dark Photons between 16.96--19.52 $\mu$eV with the HAYSTAC Experiment

We report dark photon results from HAYSTAC Phase II using data from previously reported axion searches. Additionally, we present an analysis of an unpublished dataset covering a region between 19.46--19.52 $\mu$eV. This region overlaps with a recently reported dark photon signal at 19.5 $\mu$eV with a kinetic coupling strength of $|\chi_{\text{rand}}| \simeq 6.5 \times 10^{-15}$ resulting from a reanalysis of previously published data from the TASEH collaboration. Given HAYSTAC's sensitivity, if such a signal were present, it would have appeared as a large $17.1\sigma$ excess above the noise. However, no such signal was observed. We thus exclude couplings $|\chi_{\text{rand}}|\geq 4.90\times10^{-15}$ at the 90\% confidence level over the newly reported region. In addition, using our previously reported axion data, we exclude couplings $|\chi_{\text{rand}}|\geq2.90\times 10^{-15}$ between 16.96--19.46 $\mu$eV at the 90\% confidence level.

hep-ex

Noise limits for dc SQUID readout of high-$Q$ resonators below 300 MHz

We present the limits on noise for the readout of cryogenic high-$Q$ resonators using dc Superconducting Quantum Interference Devices (SQUIDs) below 300 MHz. This analysis uses realized first-stage SQUIDs (previously published), whose performance is well described by Tesche-Clarke (TC) theory, coupled directly to the resonators. We also present data from a prototype second-stage dc SQUID array designed to couple to this first-stage SQUID as a follow-on amplifier with high system bandwidth. This analysis is the first full consideration of dc SQUID noise performance referred to a high-$Q$ resonator over this frequency range, and is presented relative to the standard quantum limit. We include imprecision, backaction, and backaction-imprecision noise correlations from TC theory, the noise contributed by the second-stage SQUIDs, wiring, and preamplifiers, and optimizations for both on-resonance measurements and off-resonance scan sensitivity. This architecture has modern relevance due to the increased interest in axion searches and the requirements of the DMRadio-m$^3$ axion search, which will use dc SQUIDs in this frequency range.

quant-ph

Dark Matter Axion Search with HAYSTAC Phase II

This Letter reports new results from the HAYSTAC experiment's search for dark matter axions in our galactic halo. It represents the widest search to date that utilizes squeezing to realize sub-quantum limited noise. The new results cover 1.71 $\mu$eV of newly scanned parameter space in the mass ranges 17.28-18.44 $\mu$eV and 18.71-19.46 $\mu$eV. No statistically significant evidence of an axion signal was observed, excluding couplings $|g_\gamma|\geq$ 2.75$\times$$|g_{\gamma}^{\text{KSVZ}}|$ and $|g_\gamma|\geq$ 2.96$\times$$|g_{\gamma}^{\text{KSVZ}}|$ at the 90$\%$ confidence level over the respective region. By combining this data with previously published results using HAYSTAC's squeezed state receiver, a total of 2.27 $\mu$eV of parameter space has now been scanned between 16.96-19.46 $\mu$eV, excluding $|g_\gamma|\geq$ 2.86$\times$$|g_{\gamma}^{\text{KSVZ}}|$ at the 90$\%$ confidence level. These results demonstrate the squeezed state receiver's ability to probe axion models over a significant mass range while achieving a scan rate enhancement relative to a quantum-limited experiment.

hep-ex

Electromagnetic modeling and science reach of DMRadio-m$^3$

DMRadio-m$^3$ is an experiment that is designed to be sensitive to KSVZ and DFSZ QCD axion models in the 10--200\,MHz (41 neV$/c^2$ -- 0.83 $\mu$eV/$c^2$) range. The experiment uses a solenoidal dc magnetic field to convert an axion dark-matter signal to an ac electromagnetic response in a coaxial copper pickup. The current induced by this axion signal is measured by dc SQUIDs. In this work, we present the electromagnetic modeling of the response of the experiment to an axion signal over the full frequency range of DMRadio-m$^3$, which extends from the low-frequency, lumped-element limit to a regime where the axion Compton wavelength is only a factor of two larger than the detector size. With these results, we determine the live time and sensitivity of the experiment. The primary science goal of sensitivity to DFSZ axions across 30--200 MHz can be achieved with a $3\sigma$ live scan time of 2.9 years.

hep-ex

New Results from HAYSTAC's Phase II Operation with a Squeezed State Receiver

A search for dark matter axions with masses $>10 \mu eV/c^{2}$ has been performed using the HAYSTAC experiment's squeezed state receiver to achieve sub-quantum limited noise. This report includes details of the design and operation of the experiment previously used to search for axions in the mass ranges $16.96-17.12$ and $17.14-17.28 \mu eV/c^{2}$($4.100-4.140$GHz) and $4.145-4.178$GHz) as well as upgrades to facilitate an extended search at higher masses. These upgrades include improvements to the data acquisition routine which have reduced the effective dead time by a factor of 5, allowing for the new region to be scanned $\sim$1.6 times faster with comparable sensitivity. No statistically significant evidence of an axion signal is found in the range $18.44-18.71\mu eV/c^{2}$($4.459-4.523$GHz), leading to an aggregate upper limit exclusion at the $90\%$ level on the axion-photon coupling of $2.06\times g_{\gamma}^{KSVZ}$.

hep-ex

Projected Sensitivity of DMRadio-m$^3$: A Search for the QCD Axion Below $1\,\mu$eV

The QCD axion is one of the most compelling candidates to explain the dark matter abundance of the universe. With its extremely small mass ($\ll 1\,\mathrm{eV}/c^2$), axion dark matter interacts as a classical field rather than a particle. Its coupling to photons leads to a modification of Maxwell's equations that can be measured with extremely sensitive readout circuits. DMRadio-m$^3$ is a next-generation search for axion dark matter below $1\,\mu$eV using a $>4$ T static magnetic field, a coaxial inductive pickup, a tunable LC resonator, and a DC-SQUID readout. It is designed to search for QCD axion dark matter over the range $20\,\mathrm{neV}\lesssim m_ac^2\lesssim 800\,\mathrm{neV}$ ($5\,\mathrm{MHz}<\nu<200\,\mathrm{MHz}$). The primary science goal aims to achieve DFSZ sensitivity above $m_ac^2\approx 120$ neV (30 MHz), with a secondary science goal of probing KSVZ axions down to $m_ac^2\approx40\,\mathrm{neV}$ (10 MHz).

hep-ex

New Horizons: Scalar and Vector Ultralight Dark Matter

The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical, largely coherent field. This white paper focuses on searches for wavelike scalar and vector dark matter candidates.

hep-ex

Axion Dark Matter

Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.

hep-ex

Exploration of Wire Array Metamaterials for the Plasma Axion Haloscope

A plasma haloscope has recently been proposed as a feasible approach to extend the search for dark matter axions above 10 GHz ($\sim$ 40 $\mu$eV), whereby the microwave cavity in a conventional axion haloscope is supplanted by a wire array metamaterial. As the plasma frequency of a metamaterial is determined by its unit cell, and is thus a bulk property, a metamaterial resonator of any frequency can be made arbitrarily large, in contrast to a microwave cavity which incurs a steep penalty in volume with increasing frequency. We have investigated the basic properties of wire array metamaterials through $S_{21}$ measurements in the 10 GHz range. Excellent agreement with theoretical models is found, by which we project achievable quality factors to be of order $10^{4}$ in an actual axion search. Furthermore, schemes for tuning the array over a usable dynamic range ($30\%$ in frequency) appear practical from an engineering perspective.

hep-ex

Introducing DMRadio-GUT, a search for GUT-scale QCD axions

The QCD axion is a leading dark matter candidate that emerges as part of the solution to the strong CP problem in the Standard Model. The coupling of the axion to photons is the most common experimental probe, but much parameter space remains unexplored. The coupling of the QCD axion to the Standard Model scales linearly with the axion mass; therefore, the highly-motivated region 0.4-120 neV, corresponding to a GUT-scale axion, is particularly difficult to reach. This paper presents the design requirements for a definitive search for GUT-scale axions and reviews the technological advances needed to enable this program.

hep-ex

A quantum-enhanced search for dark matter axions

In dark matter axion searches, quantum uncertainty manifests as a fundamental noise source, limiting the measurement of the quadrature observables used for detection. We use vacuum squeezing to circumvent the quantum limit in a search for a new particle. By preparing a microwave-frequency electromagnetic field in a squeezed state and near-noiselessly reading out only the squeezed quadrature, we double the search rate for axions over a mass range favored by recent theoretical projections. We observe no signature of dark matter axions in the combined $16.96-17.12$ and $17.14-17.28\spaceμ\text{eV}/c^2$ mass window for axion-photon couplings above $g_γ = 1.38\times g_γ^\text{KSVZ}$, reporting exclusion at the 90% level.

quant-ph