SearcharxivSearch

arXiv subjects

A. Ejlli

Publications and source records attributed to A. Ejlli.

10 recordsLinked to original sources

LIGO Detector Characterization in the Second and Third Parts of the Fourth Observing Run

LIGO detector characterization efforts enabled the confident detection of gravitational waves from hundreds of compact binary coalescences during the fourth observing run. Reliable production of high quality detector data and rapid noise mitigation efforts allow the extraction of the most in-depth knowledge of gravitational wave sources and their progenitors. In this paper we describe LIGO detector characterization activities during the second and third parts of O4-O4b and O4c. We summarize changes in detector configuration and performance at the LIGO Hanford and LIGO Livingston Observatories between the end of the first part of O4a and the end of O4c, including upgrades made during the commissioning break preceding O4b and during repairs performed in O4c. We describe instrumental investigations carried out at both sites designed to understand and subsequently mitigate the effect on detector sensitivity of transient glitches, narrowband spectral lines, and vibration-driven noise, among other data quality concerns. We then review the tools and procedures used to validate gravitational wave candidates and the data quality products thus supplied to searches for gravitational waves from compact binary coalescences and unmodeled transients, continuous gravitational waves, and the stochastic gravitational wave background. The efforts of the detector characterization group are essential for maintaining and improving the sensitivity and reliability of the LIGO detectors especially as observing runs lengthen and more events are detected. We conclude with prospects for LIGO detector characterization activities in future observing runs.

astro-ph.IM

Advanced LIGO detector performance in the fourth observing run

On May 24th, 2023, the Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO), joined by the Advanced Virgo and KAGRA detectors, began the fourth observing run for a two-year-long dedicated search for gravitational waves. The LIGO Hanford and Livingston detectors have achieved an unprecedented sensitivity to gravitational waves, with an angle-averaged median range to binary neutron star mergers of 152 Mpc and 160 Mpc, and duty cycles of 65.0% and 71.2%, respectively, with a coincident duty cycle of 52.6%. The maximum range achieved by the LIGO Hanford detector is 165 Mpc and the LIGO Livingston detector 177 Mpc, both achieved during the second part of the fourth observing run. For the fourth run, the quantum-limited sensitivity of the detectors was increased significantly due to the higher intracavity power from laser system upgrades and replacement of core optics, and from the addition of a 300 m filter cavity to provide the squeezed light with a frequency-dependent squeezing angle, part of the A+ upgrade program. Altogether, the A+ upgrades led to reduced detector-wide losses for the squeezed vacuum states of light which, alongside the filter cavity, enabled broadband quantum noise reduction of up to 5.2 dB at the Hanford observatory and 6.1 dB at the Livingston observatory. Improvements to sensors and actuators as well as significant controls commissioning increased low frequency sensitivity. This paper details these instrumental upgrades, analyzes the noise sources that limit detector sensitivity, and describes the commissioning challenges of the fourth observing run.

gr-qc

Polarimetry for measuring the vacuum magnetic birefringence with quasi-static fields: a systematics study for the VMB@CERN experiment

We present an experimental systematics study of the polarimetric method for measuring the vacuum magnetic birefringence based on a pair of rotating half-wave plates. The presence of a systematic effect at the same frequency as the sought for magneto-optical effect inhibits the use of strictly constant magnetic fields. We characterise this systematic, discuss its origin and propose a viable workaround.

physics.optics

The PVLAS experiment: a 25 year effort to measure vacuum magnetic birefringence

This paper describes the 25 year effort to measure vacuum magnetic birefringence and dichroism with the PVLAS experiment. The experiment went through two main phases: the first using a rotating superconducting magnet and the second using two rotating permanent magnets. The experiment was not able to reach the predicted value from QED. Nonetheless the experiment set the current best limits on vacuum magnetic birefringence and dichroism for a field of $B_{\rm ext} = 2.5$ T, namely, $Δn^{\rm (PVLAS)} = (12\pm17)\times10^{-23}$ and $|Δκ|^{\rm (PVLAS)} = (10\pm28)\times10^{-23}$. The uncertainty on $Δn^{\rm (PVLAS)}$ is about a factor 7 above the predicted value of $Δn^{\rm (QED)} = 2.5\times10^{-23}$ @ 2.5 T.

physics.optics

Intrinsic mirror noise in Fabry-Perot based polarimeters: the case for the measurement of vacuum magnetic birefringence

Although experimental efforts have been active for about 30 years now, a direct laboratory observation of vacuum magnetic birefringence, an effect due to vacuum fluctuations, still needs confirmation. Indeed, the predicted birefringence of vacuum is $Δn = 4.0\times 10^{-24}$ @ 1~T. One of the key ingredients when designing a polarimeter capable of detecting such a small birefringence is a long optical path length within the magnetic field and a time dependent effect. To lengthen the optical path within the magnetic field a Fabry-Perot optical cavity is generally used with a finesse ranging from ${\cal F} \approx 10^4$ to ${\cal F} \approx7\times 10^5$. Interestingly, there is a difficulty in reaching the predicted shot noise limit of such polarimeters. We have measured the ellipticity and rotation noises along with a Cotton-Mouton and a Faraday effect as a function of the finesse of the cavity of the PVLAS polarimeter. The observations are consistent with the idea that the cavity mirrors generate a birefringence-dominated noise whose ellipticity is amplified by the cavity itself. The optical path difference sensitivity at $10\;$Hz is $S_{Δ{\cal D}}=6\times 10^{-19}\;$m$/\sqrt{\rm Hz}$, a value which we believe is consistent with an intrinsic thermal noise in the mirror coatings.

physics.ins-det

The PVLAS experiment: measuring vacuum magnetic birefringence and dichroism with a birefringent Fabry-Perot cavity

Vacuum magnetic birefringence was predicted long time ago and is still lacking a direct experimental confirmation. Several experimental efforts are striving to reach this goal, and the sequence of results promises a success in the next few years. This measurement generally is accompanied by the search for hypothetical light particles that couple to two photons. The PVLAS experiment employs a sensitive polarimeter based on a high finesse Fabry-Perot cavity. In this paper we report on the latest experimental results of this experiment. The data are analysed taking into account the intrinsic birefringence of the dielectric mirrors of the cavity. Besides the limit on the vacuum magnetic birefringence, the measurements also allow the model-independent exclusion of new regions in the parameter space of axion-like and milli-charged particles. In particular, these last limits hold also for all types of neutrinos, resulting in a laboratory limit on their charge.

physics.optics

New PVLAS model independent limit for the axion coupling to $γγ$ for axion masses above 1meV

During 2014 the PVLAS experiment has started data taking with a new apparatus installed at the INFN Section of Ferrara, Italy. The main target of the experiment is the observation of magnetic birefringence of vacuum. According to QED, the ellipticity generated by the magnetic birefringence of vacuum in the experimental apparatus is expected to be $ψ^{\rm(QED)} \approx 5\times10^{-11}$. No ellipticity signal is present so far with a noise floor $ψ^{\rm(noise)} \approx 2.5\times10^{-9}$ after 210 hours of data taking. The resulting ellipticity limit provides the best model independent upper limit on the coupling of axions to $γγ$ for axion masses above $10^{-3}$eV.

hep-ex

First results from the new PVLAS apparatus: a new limit on vacuum magnetic birefringence

Several groups are carrying out experiments to observe and measure vacuum magnetic birefringence, predicted by Quantum Electrodynamics (QED). We have started running the new PVLAS apparatus installed in Ferrara, Italy, and have measured a noise floor value for the unitary field magnetic birefringence of vacuum $Δn_u^{\rm (vac)}= (4\pm 20) \times 10^{-23}$ T$^{-2}$ (the error represents a 1$σ$ deviation). This measurement is compatible with zero and hence represents a new limit on vacuum magnetic birefringence deriving from non linear electrodynamics. This result reduces to a factor 50 the gap to be overcome to measure for the first time the value of $Δn_u^{\rm (vac,QED)}$ predicted by QED: $Δn_u^{\rm (vac,QED)}= 4\times 10^{-24}$ ~T$^{-2}$. These birefringence measurements also yield improved model-independent bounds on the coupling constant of axion-like particles to two photons, for masses greater than 1 meV, along with a factor two improvement of the fractional charge limit on millicharged particles (fermions and scalars), including neutrinos.

quant-ph

Measurement of the Cotton Mouton effect of water vapour

In this paper we report on a measurement of the Cotton Mouton effect of water vapour. Measurement performed at room temperature ($T=301$ K) with a wavelength of 1064 nm gave the value $Δn_u = (6.67 \pm 0.45) \cdot 10^{-15}$ for the unit magnetic birefringence (1 T magnetic field and atmospheric pressure).

physics.chem-ph