SearcharxivSearch

arXiv subjects

A. Endo

Publications and source records attributed to A. Endo.

At least 19 recordsLinked to original sources

Enhanced electron-beam lithography to reduce the frequency scatter of 200-400 GHz superconducting microstrip resonators for on-chip filterbank spectrometers

Integrated superconducting spectrometers (ISSs) provide the instantaneous bandwidth, sensitivity, and scalable architecture for large-scale spectroscopic surveys in submillimeter-wave astronomy and cosmology. However, the accuracy with which the resonant frequencies of superconducting microstrip band pass filters can be spaced, has limited the spectral resolution for these spectrometers with continuous spectral coverage to $\frac{F}{\Delta F} < 500$. The origin of this frequency scatter has been largely unknown. In this work, we demonstrate a four-fold improvement in the frequency spacing of superconducting microstrip resonators by optimizing electron-beam lithography. We find that reducing the beam step size (BSS) on the nanometer scale reduces the random frequency scatter, and that avoiding main-field stitching across filter patterns can eliminate a systematic frequency shift between groups of resonators, indicating the different origins of these two modes of frequency deviation. These findings demonstrate that nanometer-scale control of lithographic processes is imperative for the realization of the next-generation integrated superconducting spectrometers with higher spectral resolution.

physics.ins-det

gateau: an observation simulator for ground-based submillimeter astronomy with integral field units and kinetic inductance detectors

Submillimeter (submm) integral field units (IFUs) utilising kinetic inductance detectors (KIDs) are a promising instrument architecture for the study of galaxies, galaxy clusters, and the large-scale structure of the Universe. In order to design successful experiments targeting these science cases, several aspects such as instrument design, observation and calibration strategies, and data reduction pipelines must be collectively developed, tested, and optimised. This can be achieved through end-to-end simulations of the experiment, allowing for quantitative assessment of the aforementioned aspects. To this end, we have developed gateau, a modular, flexible, and efficient simulator for submm IFU observations of astronomical sources. The simulator consists of a Python interface, powered by a C/C++ backend that uses CUDA for GPU-acceleration, and is publicly available and fully open-source. gateau simulates observations by taking user input such as an astronomical source, a set of atmospheric screens, a scan pattern, and telescope and instrument parameters. It then propagates the source signal to the detectors. A physically motivated photon-noise model is used to add a white noise component to the received power. Detector noise is added as temporally correlated pink noise. The output is stored in the form of time-ordered datasets. We validated gateau against observations with DESHIMA 2.0, a superconducting, ultra-wideband spectrometer utilising KIDs and on-chip filterbank technology. We show that we can reproduce real observations of the atmosphere and Uranus with gateau simulations. Lastly, we present a use case to show how gateau can simulate long observations in timespans orders of magnitude smaller than the observation time itself, highlighting its applicability and efficiency.

astro-ph.IM

Advances in the Fabrication of On-chip Superconducting Integral Field Units for CMB and Line-Intensity Astronomy

Studying the polarization and spectral distortion of the Cosmic Microwave Background (CMB) in tandem with intensity fluctuations of the Cosmic Infrared Background (CIB) allows us to verify our assumptions on cosmic inflation and investigate the dynamics and evolution of galaxy clusters in the last 10 billion years. Because of its broadband emission and being an all-sky extended source, observing the entire CMB in detail is a very time-consuming and expensive exercise. Fortunately, in the last few years, the on-chip superconducting spectrometer technology has moved out of the lab and into the telescope. With its compact size and background-limited sensitivity, this family of instruments is particularly well-suited for fast and large area observations in a relatively unexplored range of the electromagnetic spectrum. However, recent examples of this technology do not yet reach the requirements needed for large spectroscopic and polarimetric surveys of the CMB. We formulate several of these requirements and introduce novel on-chip components and fabrication techniques. We introduce a cross-over to enable distinguishing signal polarization, minimize signal loss by locally optimized lithography of a coplanar-waveguide (CPW), lower the spectral resolution of microstrip filters by deposition of a dielectric layer, and increase the yield of the spectrometer array by removing individual line shorts. These together have culminated in the successful fabrication of a fourteen-spaxel IFU.

physics.ins-det

DESHIMA 2.0: A 200-400 GHz Ultra-wideband Integrated Superconducting Spectrometer

DESHIMA (Deep Spectroscopic HIgh-redshift MApper) is a broadband integrated superconducting spectrometer (ISS) for millimeter (mm) / sub-millimeter (sub-mm) wave astronomy based on Kinetic Inductance Detectors (KIDs). This paper describes characterization of DESHIMA 2.0 in laboratory settings. The instrument features NbTiN superconducting microstrip (MS) filters with low-loss a-SiC:H dielectric and an ultra-wideband leaky-wave antenna. A laboratory setup was designed, incorporating the cryostat housing cryogenic optics and ISS chip comprising 339 KIDs connected to MS filters tuned for (sub-)mm wave frequencies. Room-temperature mirrors on a hexapod stage allowed precise positioning and alignment of optical elements. The sky-position chopper was positioned on a motor-controlled stage for fine-tuned control over its position and alignment. Thanks to the multiplexing capability of KIDs, we could simultaneously measure multiple performance metrics across the entire frequency range. We showed that DESHIMA 2.0 achieved significant improvements in performance compared to its predecessor (DESHIMA 1.0): measured instantaneous frequency coverage was 200$-$400 GHz with a mean filter $Q_{filter}$ of $340 \pm 50$; instrument efficiency reached $\sim8$ \%, indicating 4 times wider band coverage and 4 times higher sensitivity. The yield rate for MS filters exceeded 98 \%. The estimated aperture efficiency from measured beam patterns agreed well with the designed value of approximately 70 \%. The telescope far-field beam patterns calculated from measured beam patterns also exhibited good agreement with design specifications. We also demonstrated validity of a new method of absolute frequency calibration using the data from beam pattern measurement.

astro-ph.IM

Alignment and optical verification of DESHIMA 2.0 at ASTE

We developed, characterized, and verified an alignment procedure for the DESHIMA 2.0 instrument, an ultra wide-band spectrometer operating between 200--400 GHz, at the ASTE telescope. To this end, we mounted the warm optics, consisting of a modified Dragonian dual reflector system, on a motor controlled hexapod. Crucial in the alignment procedure is our sky chopper, which allows fast beam switching. It has a small entrance and exit aperture coupling to (cold) sky, which creates a measurable signal with respect to the warm cabin environment. By scanning the instrument beam across the entrance aperture of the sky chopper using the hexapod, we found the hexapod configuration that produced the lowest signal on our detectors, implying the beam is coupled fully to cold sky and not the warm cabin. We first characterized the alignment procedure in the laboratory, where we used a vat containing liquid nitrogen as the cold source behind the sky chopper. Then, we applied the alignment procedure to DESHIMA 2.0 at ASTE. We found that the alignment procedure significantly improved the aperture efficiency compared to previously reported values of the aperture efficiency of DESHIMA at ASTE, which indicates the veracity of the alignment procedure.

astro-ph.IM

Vibrational modes as the origin of dielectric loss at 0.27$\unicode{x2013}$100 THz in a-SiC:H

Low-loss deposited dielectrics are beneficial for the advancement of superconducting integrated circuits for astronomy. In the microwave band ($\mathrm{\sim}$1$\unicode{x2013}$10 GHz) the cryogenic and low-power dielectric loss is dominated by two-level systems. However, the origin of the loss in the millimeter-submillimeter band ($\mathrm{\sim}$0.1$\unicode{x2013}$1 THz) is not understood. We measured the loss of hydrogenated amorphous SiC (a-SiC:H) films in the 0.27$\unicode{x2013}$100 THz range using superconducting microstrip resonators and Fourier-transform spectroscopy. The agreement between the loss data and a Maxwell-Helmholtz-Drude dispersion model suggests that vibrational modes above 10 THz dominate the loss in the a-SiC:H above 200 GHz.

astro-ph.IM

Optimisation-based alignment of wideband integrated superconducting spectrometers for sub-mm astronomy

Integrated superconducting spectrometers (ISSs) for wideband sub-mm astronomy utilise quasi-optical systems for coupling radiation from the telescope to the instrument. Misalignment in these systems is detrimental to the system performance. The common method of using an optical laser to align the quasi-optical components requires accurate alignment of the laser to the sub-mm beam coming from the instrument, which is not always guaranteed to a sufficient accuracy. We develop an alignment strategy for wideband ISSs directly utilising the sub-mm beam of the wideband ISS. The strategy should be applicable in both telescope and laboratory environments. Moreover, the strategy should deliver similar quality of the alignment across the spectral range of the wideband ISS. We measure misalignment in a quasi-optical system operating at sub-mm wavelengths using a novel phase and amplitude measurement scheme, capable of simultaneously measuring the complex beam patterns of a direct-detecting ISS across a harmonic range of frequencies. The direct detection nature of the MKID detectors in our device-under-test, DESHIMA 2.0, necessitates the use of this measurement scheme. Using geometrical optics, the measured misalignment, a mechanical hexapod, and an optimisation algorithm, we follow a numerical approach to optimise the positioning of corrective optics with respect to a given cost function. Laboratory measurements of the complex beam patterns are taken across a harmonic range between 205 and 391 GHz and simulated through a model of the ASTE telescope in order to assess the performance of the optimisation at the ASTE telescope. Laboratory measurements show that the optimised optical setup corrects for tilts and offsets of the sub-mm beam. Moreover, we find that the simulated telescope aperture efficiency is increased across the frequency range of the ISS after the optimisation.

astro-ph.IM

DESHIMA 2.0: Rapid redshift surveys and multi-line spectroscopy of dusty galaxies

We present a feasibility study for the high-redshift galaxy part of the Science Verification Campaign with the 220-440 GHz DESHIMA 2.0 integrated superconducting spectrometer on the ASTE telescope. The first version of the DESHIMA 2.0 chip has been recently manufactured and tested in the lab. Based on these realistic performance measurements, we evaluate potential target samples and prospects for detecting the [CII] and CO emission lines. The planned observations comprise two distinct, but complementary objectives: (1) acquiring spectroscopic redshifts for dusty galaxies selected in far-infrared/mm-wave continuum surveys; (2) multi-line observations to infer physical conditions in dusty galaxies.

astro-ph.IM

Hydrogenated Amorphous Silicon Carbide: A Low-loss Deposited Dielectric for Microwave to Submillimeter Wave Superconducting Circuits

Low-loss deposited dielectrics will benefit superconducting devices such as integrated superconducting spectrometers, superconducting qubits and kinetic inductance parametric amplifiers. Compared with planar structures, multi-layer structures such as microstrips are more compact and eliminate radiation loss at high frequencies. Multi-layer structures are most easily fabricated with deposited dielectrics, which typically exhibit higher dielectric loss than crystalline dielectrics. We measured the sub-kelvin and low-power microwave and mm-submm wave dielectric loss of hydrogenated amorphous silicon carbide (a-SiC:H), using a superconducting chip with NbTiN/a-SiC:H/NbTiN microstrip resonators. We deposited the a-SiC:H by plasma-enhanced chemical vapor deposition at a substrate temperature of 400{\deg}C. The a-SiC:H has a mm-submm loss tangent ranging from $0.80 \pm 0.01 \times 10^{-4}$ to $1.43 \pm 0.04 \times 10^{-4}$ in the range of 270 to 385 GHz. The microwave loss tangent is $3.2 \pm 0.2 \times 10^{-5}$. These are the lowest low-power sub-kelvin loss tangents that have been reported for microstrip resonators at mm-submm and microwave frequencies. We observe that the loss tangent increases with frequency. The a-SiC:H films are free of blisters and have low stress: $-$20 MPa compressive at 200 nm thickness to 60 MPa tensile at 1000 nm thickness.

cond-mat.mtrl-sci

Superconducting Microstrip Losses at Microwave and Sub-millimeter wavelengths

We present a lab-on-chip experiment to accurately measure losses of superconducting microstrip lines at microwave and sub-mm wavelengths. The microstrips are fabricated from NbTiN, which is deposited using reactive magnetron sputtering, and amorphous silicon which is deposited using plasma-enhanced chemical vapor deposition (PECVD). Sub-mm wave losses are measured using on-chip Fabry-P{é}rot resonators (FPR) operating around $350\ $GHz. Microwave losses are measured using shunted half-wave resonators with an identical geometry and fabricated on the same chip. We measure a loss tangent of the amorphous silicon at single-photon energies of $\tanδ=3.7\pm0.5\times10^{-5}$ at $6\ $GHz and $\tanδ= 2.1\pm 0.1\times10^{-4}$ at $350\ $GHz. These results represent very low losses for deposited dielectrics, but the sub-mm wave losses are significantly higher than the microwave losses, which cannot be understood using the standard two-level system loss model.

physics.ins-det

Large format imaging spectrograph for the Large Submillimeter Telescope (LST)

We present a conceptual study of a large format imaging spectrograph for the Large Submillimeter Telescope (LST) and the Atacama Large Aperture Submillimeter Telescope (AtLAST). Recent observations of high-redshift galaxies indicate the onset of earliest star formation just a few 100 million years after the Big Bang (i.e., z = 12--15), and LST/AtLAST will provide a unique pathway to uncover spectroscopically-identified first forming galaxies in the pre-reionization era, once it will be equipped with a large format imaging spectrograph. We propose a 3-band (200, 255, and 350 GHz), medium resolution (R = 2,000) imaging spectrograph with 1.5 M detectors in total based on the KATANA concept (Karatsu et al. 2019), which exploits technologies of the integrated superconducting spectrometer (ISS) and a large-format imaging array. A 1-deg2 drilling survey (3,500 hr) will capture a large number of [O III] 88 um (and [C II] 158 um) emitters at z = 8--9, and constrain [O III] luminosity functions at z > 12.

astro-ph.IM

Suppression of radiation loss in high kinetic inductance superconducting co-planar waveguides

We present a novel lab-on-chip technique to measure the very low losses in superconducting transmission lines at (sub-) mm wavelengths. The chips consist of a 100 nm thick NbTiN Coplanar Waveguide (CPW) Fabry Perot (FP) resonator, coupled on one side to an antenna and on the other side to a Microwave Kinetic Inductance detector. Using a single frequency radiation source allows us to measure the frequency response of the FP around 350 GHz and deduce its losses. We show that the loss is dominated by radiation loss inside the CPW line that forms the FP and that it decreases with decreasing line width and increasing kinetic inductance as expected. The results can be quantitatively understood using SONNET simulations. The lowest loss is observed for a CPW with a total width of $6\ \mathrm{μm}$ and corresponds to a Q-factor of $\approx15,000$.

physics.ins-det

Mitigation of Cosmic Ray Effect on Microwave Kinetic Inductance Detector Arrays

For space observatories, the glitches caused by high energy phonons created by the interaction of cosmic ray particles with the detector substrate lead to dead time during observation. Mitigating the impact of cosmic rays is therefore an important requirement for detectors to be used in future space missions. In order to investigate possible solutions, we carry out a systematic study by testing four large arrays of Microwave Kinetic Inductance Detectors (MKIDs), each consisting of $\sim$960 pixels and fabricated on monolithic 55 mm $\times$ 55 mm $\times$ 0.35 mm Si substrates. We compare the response to cosmic ray interactions in our laboratory for different detector arrays: A standard array with only the MKID array as reference; an array with a low $T_c$ superconducting film as phonon absorber on the opposite side of the substrate; and arrays with MKIDs on membranes. The idea is that the low $T_c$ layer down-converts the phonon energy to values below the pair breaking threshold of the MKIDs, and the membranes isolate the sensitive part of the MKIDs from phonons created in the substrate. We find that the dead time can be reduced up to a factor of 40 when compared to the reference array. Simulations show that the dead time can be reduced to below 1 % for the tested detector arrays when operated in a spacecraft in an L2 or a similar far-Earth orbit. The technique described here is also applicable and important for large superconducting qubit arrays for future quantum computers.

astro-ph.IM

Low temperature magnetism of gold nano particles contained in electrochemical sugar recognition system

Low temperature magnetic properties were investigated on the gold nano particles (GNP) with an average size of 11.5 nm, assembled with molecules of ruthenium complex (Ru0) and phenylboronic acid (B0) by the proton nuclear resonance (1H-NMR) and susceptibility measurements. The temperature dependence of the NMR shift and the uniform susceptibility was described as the sum of the Curie-Weiss term and a positive constant term. From the former, the average number of Ru0 on each GNP was estimated to be 118, which is 23 % of the calculation. The finite positive constant term shows a clear contrast with the well-known fact that the bulk gold is diamagnetic. Finally, a disappearance of the motional narrowing effect in the proton NMR spectra below 60 K indicates that the wavering motion of Ru0 complexes on GNP at room temperature is frozen at low temperatures.

cond-mat.mes-hall

A kilo-pixel imaging system for future space based far-infrared observatories using microwave kinetic inductance detectors

Future astrophysics and cosmic microwave background space missions operating in the far-infrared to millimetre part of the spectrum will require very large arrays of ultra-sensitive detectors in combination with high multiplexing factors and efficient low-noise and low-power readout systems. We have developed a demonstrator system suitable for such applications. The system combines a 961 pixel imaging array based upon Microwave Kinetic Inductance Detectors (MKIDs) with a readout system capable of reading out all pixels simultaneously with only one readout cable pair and a single cryogenic amplifier. We evaluate, in a representative environment, the system performance in terms of sensitivity, dynamic range, optical efficiency, cosmic ray rejection, pixel-pixel crosstalk and overall yield at at an observation centre frequency of 850 GHz and 20% fractional bandwidth. The overall system has an excellent sensitivity, with an average detector sensitivity NEPdet=3x10^-19 W/rt(Hz) measured using a thermal calibration source. At a loading power per pixel of 50fW we demonstrate white, photon noise limited detector noise down to 300 mHz. The dynamic range would allow the detection of 1 Jy bright sources within the field of view without tuning the readout of the detectors. The expected dead time due to cosmic ray interactions, when operated in an L2 or a similar far-Earth orbit, is found to be <4%. Additionally, the achieved pixel yield is 83% and the crosstalk between the pixels is <-30dB. This demonstrates that MKID technology can provide multiplexing ratios on the order of a 1000 with state-of-the-art single pixel performance, and that the technology is now mature enough to be considered for future space based observatories and experiments.

astro-ph.IM

Reactive magnetron sputter deposition of superconducting niobium titanium nitride thin films with different target sizes

The superconducting critical temperature (Tc > 15K) of niobium titanium nitride (NbTiN) thin films allows for low-loss circuits up to 1.1 THz, enabling on-chip spectroscopy and multi-pixel imaging with advanced detectors. The drive for large scale detector microchips is demanding NbTiN films with uniform properties over an increasingly larger area. This article provides an experimental comparison between two reactive d.c. sputter systems with different target sizes: a small target (100mm diameter) and a large target (127 mm x 444.5 mm). This article focuses on maximizing the Tc of the films and the accompanying I-V characteristics of the sputter plasma, and we find that both systems are capable of depositing films with Tc > 15 K. The resulting film uniformity is presented in a second manuscript in this volume. We find that these films are deposited within the transition from metallic to compound sputtering, at the point where target nitridation most strongly depends on nitrogen flow. Key in the deposition optimization is to increase the system's pumping speed and gas flows to counteract the hysteretic effects induced by the target size. Using the I-V characteristics as a guide proves to be an effective way to optimize a reactive sputter system, for it can show whether the optimal deposition regime is hysteresis-free and accessible.

cond-mat.supr-con

Superconducting NbTiN Thin Films with Highly Uniform Properties over a 100 mm diameter Wafer

Uniformity in thickness and electronic properties of superconducting niobium titanium nitride (NbTiN) thin films is a critical issue for upscaling superconducting electronics, such as microwave kinetic inductance detectors for submillimeter wave astronomy. In this article we make an experimental comparison between the uniformity of NbTiN thin films produced by two DC magnetron sputtering systems with vastly different target sizes: the Nordiko 2000 equipped with a circular 100mm diameter target, and the Evatec LLS801 with a rectangular target of 127 mm x 444.5 mm. In addition to the films deposited staticly in both systems, we have also deposited films in the LLS801 while shuttling the substrate in front of the target, with the aim of further enhancing the uniformity. Among these three setups, the LLS801 system with substrate shuttling has yielded the highest uniformity in film thickness (+/-2%), effective resistivity (decreasing by 5% from center to edge), and superconducting critical temperature (T_c = 15.0 K - 15.3 K) over a 100 mm diameter wafer. However, the shuttling appears to increase the resistivity by almost a factor of 2 compared to static deposition. Surface SEM inspections suggest that the shuttling could have induced a different mode of microstructural film growth.

astro-ph.IM

Experimentally simulating the dynamics of quantum light and matter at ultrastrong coupling

The quantum Rabi model describing the fundamental interaction between light and matter is a cornerstone of quantum physics. It predicts exotic phenomena like quantum phase transitions and ground-state entanglement in the ultrastrong-coupling (USC) regime, where coupling strengths are comparable to subsystem energies. Despite progress in many experimental platforms, the few experiments reaching USC have been limited to spectroscopy: demonstrating USC dynamics remains an outstanding challenge. Here, we employ a circuit QED chip with moderate coupling between a resonator and transmon qubit to realise accurate digital quantum simulation of USC dynamics. We advance the state of the art in solid-state digital quantum simulation by using up to 90 second-order Trotter steps and probing both subsystems in a combined Hilbert space dimension $\sim80$, demonstrating the Schrödinger-cat like entanglement and build-up of large photon numbers characteristic of deep USC. This work opens the door to exploring extreme USC regimes, quantum phase transitions and many-body effects in the Dicke model.

quant-ph