Searcharxiv⌕ Search

arXiv subjects

A. Freise

Publications and source records attributed to A. Freise.

28 records · Page 2Linked to original sources

Using the etalon effect for in-situ balancing of the Advanced Virgo arm cavities

Several large-scale interferometric gravitational-wave detectors use resonant arm cavities to enhance the light power in the interferometer arms. These cavities are based on different optical designs: One design uses wedged input mirrors to create additional optical pick-off ports for deriving control signals. The second design employs input mirrors without wedge and thus offers the possibility to use the etalon effect inside the input mirrors for tuning the finesse of the arm cavities. In this article we introduce a concept of maximized flexibility that combines both of these options, by featuring wedges at the input mirrors and using the etalon effect instead in the end mirrors. We present a design for the arm cavities of Advanced Virgo. We have used numerical simulations to derive requirements for the manufacturing accuracy of an end mirror etalon for Advanced Virgo. Furthermore, we give analytical approximations for the achievable tuning range of the etalon in dependence on the reflectance, the curvature and the orientation of the etalon back surface.

gr-qc↗

Phase and alignment noise in grating interferometers

Diffraction gratings have been proposed as core optical elements in future laser-interferometric gravitational-wave detectors. In this paper we derive equations for the coupling between alignment noise and phase noise at diffraction gratings. In comparison to a standard reflective component (mirror or beam splitter) the diffractive nature of the gratings causes an additional coupling of geometry changes into alignment and phase noise. Expressions for the change in angle and optical path length of each outgoing beam are provided as functions of a translation or rotation of the incoming beam with respect to the grating. The analysis is based entirely on the grating equation and the geometry of the setup. We further analyse exemplary optical setups which have been proposed for the use in future gravitational wave detectors. We find that the use of diffraction gratings yields a strong coupling of alignment noise into phase noise. By comparing the results with the specifications of current detectors we show that this additional noise coupling results in new, challenging requirements for the suspension and isolation systems for the optical components.

gr-qc↗

A novel concept for increasing the peak sensitivity of LIGO by detuning the arm cavities

We introduce a concept that uses detuned arm cavities to increase the shot noise limited sensitivity of LIGO without increasing the light power inside the arm cavities. Numerical simulations show an increased sensitivity between 125 and 400 Hz, with a maximal improvement of about 80% around 225 Hz, while the sensitivity above 400Hz is decreased. Furthermore our concept is found to give a sensitivity similar to that of a conventional RSE configuration with a Signal-Recycling mirror of moderate reflectivity. In the near future detuned arm cavities might be a beneficial alternative to RSE, due the potentially less hardware intensive implementation of the proposed concept.

gr-qc↗

Quantum-Noise Power Spectrum of Fields with Discrete Classical Components

We present an algorithmic approach to calculate the quantum-noise spectral density of photocurrents generated by optical fields with arbitrary discrete classical spectrum in coherent or squeezed states. The measurement scheme may include an arbitrary number of demodulations of the photocurrent. Thereby, our method is applicable to the general heterodyne detection scheme which is implemented in many experiments. For some of these experiments, e.g. in laser-interferometric gravitational-wave detectors, a reliable prediction of the quantum noise of fields in coherent and squeezed states plays a decisive role in the design phase and detector characterization. Still, our investigation is limited in two ways. First, we only consider coherent and squeezed states of the field and second, we demand that the photocurrent depends linearly on the field's vacuum amplitudes which means that at least one of the classical components is comparatively strong.

quant-ph↗

Automatic Mirror Alignment for VIRGO: First experimental demonstration of the Anderson technique on a large-scale interferometer

The French-Italian interferometric gravitational wave detector VIRGO is currently being commissioned. Its principal instrument is a Michelson laser interferometer with 3 km long optical cavities in the arms and a power-recycling mirror. The interferometer resides in an ultra-high vacuum system and the mirrors are suspended from multistage pendulums for seismic isolation. This type of laser interferometer reaches its maximum sensitivity only when the optical setup is held actively very accurately at a defined operating point: control systems using the precise interferometer signals stabilise the longitudinal and angular positions of the optical component. This paper gives an overview of the control system for the angular degrees of freedom; we present the current status of the system and report the first experimental demonstration of the Anderson technique on a large-scale interferometer.

gr-qc↗

Status of VIRGO

The French-Italian interferometric gravitational wave detector VIRGO is currently being commissioned. Its principal instrument is a Michelson interferometer with 3 km long optical cavities in the arms and a power-recycling mirror. This paper gives an overview of the present status of the system. We report on the presently attained sensitivity and the system's performance during the recent commissioning runs. After a sequence of intermediate stages, the interferometer is now being used in the so-called recombined configuration. The input laser beam is spatially filtered by a 144 m long input mode-cleaner before being injected to the main interferometer. The main optics are suspended from so-called \sa s, which provide an excellent seismic isolation. The two 3 km long Fabry-Perot arm cavities are kept in resonance with the laser light, and the Michelson interferometer is held on the dark fringe. An automatic mirror alignment system based on the Anderson technique has been implemented for the arm cavities. The light leaving the dark port contains the gravitational wave signal; this light is filtered by an output mode-cleaner before being detected by a photo detector. This setup is the last step on the way to the final configuration, which will include power recycling.

gr-qc↗

Frequency domain interferometer simulation with higher-order spatial modes

FINESSE is a software simulation that allows to compute the optical properties of laser interferometers as they are used by the interferometric gravitational-wave detectors today. It provides a fast and versatile tool which has proven to be very useful during the design and the commissioning of gravitational-wave detectors. The basic algorithm of FINESSE numerically computes the light amplitudes inside an interferometer using Hermite-Gauss modes in the frequency domain. In addition, FINESSE provides a number of commands to easily generate and plot the most common signals like, for example, power enhancement, error or control signals, transfer functions and shot-noise-limited sensitivities. Among the various simulation tools available to the gravitational wave community today, FINESSE is the most advanced general optical simulation that uses the frequency domain. It has been designed to allow general analysis of user defined optical setups while being easy to install and easy to use.

gr-qc↗

Dual recycling for GEO600

Dual recycling is the combination of signal recycling and power recycling; both optical techniques improve the shot-noise-limited sensitivity of interferometric gravitational-wave detectors. In addition, signal recycling can reduce the loss of light power due to imperfect interference and allows, in principle, to beat the standard quantum limit. The interferometric gravitational-wave detector GEO600 is the first detector to use signal recycling. We have recently equipped the detector with a signal-recycling mirror with a transmittance of 1%. In this paper, we present details of the detector commissioning and the first locks of the dual- recycled interferometer.

gr-qc↗

Performance of a 1200m long suspended Fabry-Perot cavity

Using one arm of the Michelson interferometer and the power recycling mirror of the interferometric gravitational wave detector GEO600, we created a Fabry-Perot cavity with a length of 1200 m. The main purpose of this experiment was to gather first experience with the main optics, its suspensions and the corresponding control systems. The residual displacement of a main mirror is about 150 nm rms. By stabilising the length of the 1200 m long cavity to the pre-stabilised laser beam we achieved an error point frequency noise of 0.1 mHz/sqrt(Hz) at 100 Hz Fourier frequency. In addition we demonstrated the reliable performance of all included subsystems by several 10-hour-periods of continuous stable operation. Thus the full frequency stabilisation scheme for GEO600 was successfully tested.

gr-qc↗

Demonstration of detuned dual recycling at the Garching 30m laser interferometer

Dual recycling is an advanced optical technique to enhance the signal-to-noise ratio of laser interferometric gravitational wave detectors in a limited bandwidth. To optimise the center of this band with respect to Fourier frequencies of expected gravitational wave signals detuned dual recycling has to be implemented. We demonstrated detuned dual recycling on a fully suspended 30m prototype interferometer. A control scheme that allows to tune the detector to different frequencies will be outlined. Good agreement between the experimental results and numerical simulations has been achieved.

gr-qc↗