Searcharxiv⌕ Search

arXiv subjects

A. Gütlein

Publications and source records attributed to A. Gütlein.

33 records · Page 2Linked to original sources

Energy-Dependent Light Quenching in CaWO$_4$ Crystals at mK Temperatures

Scintillating CaWO$_4$ single crystals are a promising multi-element target for rare-event searches and are currently used in the direct Dark Matter experiment CRESST (Cryogenic Rare Event Search with Superconducting Thermometers). The relative light output of different particle interactions in CaWO$_4$ is quantified by Quenching Factors (QFs). These are essential for an active background discrimination and the identification of a possible signal induced by weakly interacting massive particles (WIMPs). We present the first precise measurements of the QFs of O, Ca and W at mK temperatures by irradiating a cryogenic detector with a fast neutron beam. A clear energy dependence of the QF of O and, less pronounced, of Ca was observed for the first time. Furthermore, in CRESST neutron-calibration data a variation of the QFs among different CaWO$_4$ single crystals was found. For typical CRESST detectors the QFs in the region-of-interest (10-40$\,$keV) are $QF_O^{ROI}=(11.2{\pm}0.5)\,$%, $QF_{Ca}^{ROI}=(5.94{\pm}0.49)\,$% and $QF_W^{ROI}=(1.72{\pm}0.21)\,$%. The latest CRESST data (run32) is reanalyzed using these fundamentally new results on light quenching in CaWO$_4$ having moderate influence on the WIMP analysis. Their relevance for future CRESST runs and for the clarification of previously published results of direct Dark Matter experiments is emphasized.

astro-ph.IM↗

A detector module with highly efficient surface-alpha event rejection operated in CRESST-II Phase 2

The cryogenic dark matter experiment CRESST-II aims at the direct detection of WIMPs via elastic scattering off nuclei in scintillating CaWO$_4$ crystals. We present a new, highly improved, detector design installed in the current run of CRESST-II Phase 2 with an efficient active rejection of surface-alpha backgrounds. Using CaWO$_4$ sticks instead of metal clamps to hold the target crystal, a detector housing with fully-scintillating inner surface could be realized. The presented detector (TUM40) provides an excellent threshold of ${\sim}\,0.60\,$keV and a resolution of $σ\,{\approx}\,0.090$ keV (at 2.60$\,$keV). With significantly reduced background levels, TUM40 sets stringent limits on the spin-independent WIMP-nucleon scattering cross section and probes a new region of parameter space for WIMP masses below 3$\,$GeV/c$^2$. In this paper, we discuss the novel detector design and the surface-alpha event rejection in detail.

physics.ins-det↗

Low-Temperature Scintillation Properties of CaWO4 Crystals for Rare-Event Searches

In prospect of its application in cryogenic rare-event searches, we have investigated the low-temperature scintillation properties of CaWO4 crystals down to 3.4 K under α and γ excitation. Concerning the scintillation decay times, we observe a long component in the ms range which significantly contributes to the light yield below 40K. For the first time we have measured the temperature dependence of the α/γ- ratio of the light yield. This parameter which can be used to discriminate α and γ events in scintillating bolometers is found to be about 8-15% smaller at low temperatures compared to room temperature.

physics.ins-det↗

The CRESST Dark Matter Search - Status and Perspectives

In the past years the spotlight of the search for dark matter particles widened to the low mass region, both from theoretical and experimental side. We discuss results from data obtained in 2013 with a single detector TUM40. This detector is equipped with a new upgraded holding scheme to efficiently veto backgrounds induced by surface alpha decays. This veto, the low threshold of 0.6keV and an unprecedented background level for CaWO$_4$ target crystals render TUM40 the detector with the best overall performance of CRESST-II phase 2 (July 2013 - August 2015). A low-threshold analysis allowed to investigate light dark matter particles (<3GeV/c$^2$), previously not accessible for other direct detection experiments.

physics.ins-det↗

Probing low WIMP masses with the next generation of CRESST detector

The purpose of this document is to describe the upgrade of the CRESST dark matter search at LNGS. The proposed strategy will allow to explore a region of the parameter space for spin-independent WIMP-nucleon elastic scattering corresponding to WIMP masses below 10GeV/c$^\text{2}$, that has not been covered by other experiments. These results can be achieved only with outstanding detector performances in terms of threshold and background. This proposal shows how CRESST can match these performance requirements, adding a unique piece of information to the dark matter puzzle. The results of this program will fix a new state-of-the-art in the low mass WIMP exploration, opening new perspectives of understanding the dark matter scenario.

astro-ph.IM↗

Impact of Coherent Neutrino Nucleus Scattering on Direct Dark Matter Searches based on CaWO$_4$ Crystals

Atmospheric and solar neutrinos scattering coherently off target nuclei will be an important background source for the next generation of direct dark matter searches. In this work we focus on calcium tungstate as target material. For comparison with existing works we calculate the neutrino floor indicating which sensitivities can be reached before the neutrino background appears. In addition, we investigate the sensitivities of future direct dark matter searches using CRESST-II like detectors. Extending previous works we take into account achievable energy resolutions and thresholds as well as beta and gamma backgrounds for this investigation. We show that an exploration of WIMP-nucleon cross sections below the neutrino floor is possible for exposures of $\gtrsim10$ kg-years or higher. In the third part we show that a first detection of coherent neutrino nucleus scattering of atmospheric and solar neutrinos using the same detectors and the backgrounds is feasible for exposures of $\gtrsim50$ kg-years.

hep-ph↗

Results on low mass WIMPs using an upgraded CRESST-II detector

The CRESST-II cryogenic dark matter search aims for the detection of WIMPs via elastic scattering off nuclei in CaWO$_4$ crystals. We present results from a low-threshold analysis of a single upgraded detector module. This module efficiently vetoes low energy backgrounds induced by $α$-decays on inner surfaces of the detector. With an exposure of \unit[29.35]{kg live days} collected in 2013 we set a limit on spin-independent WIMP-nucleon scattering which probes a new region of parameter space for WIMP masses below \unit[3]{GeV/c$^2$}, previously not covered in direct detection searches. A possible excess over background discussed for the previous CRESST-II phase 1 (from 2009 to 2011) is not confirmed.

astro-ph.CO↗

Neganov-Luke amplified cryogenic light detectors for the background discrimination in neutrinoless double beta decay search with TeO$_{2}$ bolometers

We demonstrate that Neganov-Luke amplified cryogenic light detectors with Transition Edge Sensor read-out can be applied for the background suppression in cryogenic experiments searching for the neutrinoless double beta decay of $^{130}\text{Te}$ with TeO$_{2}$ based bolometers. Electron and gamma induced events can be discriminated from $α$ events by detecting the Cherenkov light produced by the $β$ particles emitted in the decay. We use the Cherenkov light produced by events in the full energy peak of $^{208}\text{Tl}$ and by events from a $^{147}\text{Sm}$ source to show that at the Q-value of the neutrinoless double beta decay of $^{130}\text{Te}$ ($Q_{ββ} = 2.53 \,\text{MeV}$), a separation of $e^{-}/γ$ events from $α$ events can be achieved on an event-by-event basis with practically no reduction in signal acceptance.

physics.ins-det↗

Radiopurity of CaWO$_4$ Crystals for Direct Dark Matter Search with CRESST and EURECA

The direct dark matter search experiment CRESST uses scintillating CaWO$_4$ single crystals as targets for possible WIMP scatterings. An intrinsic radioactive contamination of the crystals as low as possible is crucial for the sensitivity of the detectors. In the past CaWO$_4$ crystals operated in CRESST were produced by institutes in Russia and the Ukraine. Since 2011 CaWO$_4$ crystals have also been grown at the crystal laboratory of the Technische Universität München (TUM) to better meet the requirements of CRESST and of the future tonne-scale multi-material experiment EURECA. The radiopurity of the raw materials and of first TUM-grown crystals was measured by ultra-low background $γ$-spectrometry. Two TUM-grown crystals were also operated as low-temperature detectors at a test setup in the Gran Sasso underground laboratory. These measurements were used to determine the crystals' intrinsic $α$-activities which were compared to those of crystals produced at other institutes. The total $α$-activities of TUM-grown crystals as low as 1.23 $\pm$ 0.06 mBq/kg were found to be significantly smaller than the activities of crystals grown at other institutes typically ranging between ~15 mBq/kg and ~35 mBq/kg.

astro-ph.IM↗

Experimental Determination of the Antineutrino Spectrum of the Fission Products of $^{238}$U

An experiment was performed at the scientific neutron source FRM II in Garching to determine the cumulative antineutrino spectrum of the fission products of $^{238}$U. This was achieved by irradiating target foils of natural uranium with a thermal and a fast neutron beam and recording the emitted $β$-spectra with a gamma-suppressing electron-telescope. The obtained $β$-spectrum of the fission products of $^{235}$U was normalized to the data of the magnetic spectrometer BILL of $^{235}$U. This method strongly reduces systematic errors in the $^{238}$U measurement. The $β$-spectrum of $^{238}$U was converted into the corresponding antineutrino spectrum. The final $\barν_e$-spectrum is given in 250 keV bins in the range from 2.875 MeV to 7.625 MeV with an energy-dependent error of 3.5 % at 3 MeV, 7.6 % at 6 MeV and $\gtrsim$ 14 % at energies $\gtrsim$ 7 MeV (68 % confidence level). Furthermore, an energy-independent uncertainty of $\sim$ 3.3 % due to the absolute normalization is added. Compared to the generally used summation calculations, the obtained spectrum reveals a slight spectral distortion of $\sim$ 10 % but returns the same value for the mean cross section per fission for the inverse beta decay.

nucl-ex↗

Low-Temperature Light Detectors: Neganov-Luke Amplification and Calibration

The simultaneous measurement of phonons and scintillation light induced by incident particles in a scintillating crystal such as CaWO4 is a powerful technique for the active rejection of background induced by gamma's and beta's and even neutrons in direct Dark Matter searches. However, less than ~1% of the energy deposited in a CaWO4 crystal is detected as light. Thus, very sensitive light detectors are needed for an efficient event-by-event background discrimination. Due to the Neganov-Luke effect, the threshold of low-temperature light detectors based on semiconducting substrates can be improved significantly by drifting the photon-induced electron-hole pairs in an applied electric field. We present measurements with low-temperature light detectors based on this amplification mechanism. The Neganov-Luke effect makes it possible to improve the signal-to-noise ratio of our light detectors by a factor of ~9 corresponding to an energy threshold of ~21 eV. We also describe a method for an absolute energy calibration using a light-emitting diode.

physics.ins-det↗

Influence of Annealing on the Optical and Scintillation Properties of CaWO$_4$ Single Crystals

We investigate the influence of oxygen annealing on the room temperature optical and scintillation properties of CaWO$_4$ single crystals that are being produced for direct Dark Matter search experiments. The applied annealing procedure reduces the absorption coefficient at the peak position of the scintillation spectrum ($\sim430$ nm) by a factor of $\sim6$ and leads to an even larger reduction of the scattering coefficient. Furthermore, the annealing has no significant influence on the \emph{intrinsic} light yield. An additional absorption occurring at $\sim400$ nm suggests the formation of O$^-$ hole centers. Light-yield measurements at room temperature where one crystal surface was mechanically roughened showed an increase of the \emph{measured} light yield by $\sim40 %$ and an improvement of the energy resolution at 59.5 keV by $\sim12 %$ for the annealed crystal. We ascribe this result to the reduction of the absorption coefficient while the surface roughening is needed to compensate for the also observed reduction of the scattering coefficient after annealing.

physics.optics↗

Solar and Atmospheric Neutrinos: Limitations for Direct Dark Matter Searches

In experiments for direct dark matter searches, neutrinos coherently scattering off nuclei can produce similar events as Weakly Interacting Massive Particles (WIMPs). To reach sensitivities better than about 10^-10 pb for the elastic WIMP nucleon spin-independent cross section in the zero-background limit, energy thresholds for nuclear recoils should be >2.05 keV for CaWO_4, >4.91 keV for Ge, >2.89 keV for Xe, >8.62 keV for Ar and >15.93 keV for Ne as target material. Atmospheric neutrinos limit the achievable sensitivity for the background-free direct dark matter search to >10^-12 pb.

hep-ph↗

Solar and Atmospheric Neutrinos: Background Sources for the Direct Dark Matter Searches

In experiments for direct dark matter searches, neutrinos coherently scattering off nuclei can produce similar events as Weakly Interacting Massive Particles (WIMPs). The calculated count rate for solar neutrinos in such experiments is a few events per ton-year. This count rate strongly depends on the nuclear recoil energy threshold achieved in the experiments for the WIMP search. We show that solar neutrinos can be a serious background source for direct dark matter search experiments using Ge, Ar, Xe and CaWO_4 as target materials. To reach sensitivities better than approximatly 10^-10 pb for the elastic WIMP nucleon spin-independent cross section in the zero-background limit, energy thresholds for nuclear recoils should be approximatly >2.05 keV for CaWO_4, >4.91 keV for Ge, >2.89 keV for Xe, and >8.62 keV for Ar as target material. Next-generation experiments should not only strive for a reduction of the present energy thresholds but mainly focus on an increase of the target mass. Atmospheric neutrinos limit the achievable sensitivity for the background-free direct dark matter search to approximatly >10^-12 pb.

hep-ph↗

Neutron Scattering Facility for Characterization of CRESST and EURECA Detectors at mK Temperatures

CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) is an experiment located at the Gran Sasso underground laboratory and aimed at the direct detection of dark matter in the form of WIMPs. The setup has just completed a one year commissioning run in 2007 and is presently starting a physics run with an increased target mass. Scintillating $\mathrm{CaWO_4}$ single crystals, operated at temperatures of a few millikelvin, are used as target to detect the tiny nuclear recoil induced by a WIMP. The powerful background identification and rejection of $α$, e$^{-}$ and $γ$ events is realized via the simultaneous measurement of a phonon and a scintillation signal generated in the $\mathrm{CaWO_4}$ crystal. However, neutrons could still be misidentified as a WIMP signature. Therefore, a detailed understanding of the individual recoil behaviour in terms of phonon generation and scintillation light emission due to scattering on Ca, O or W nuclei, respectively, is mandatory. The only setup which allows to perform such measurements at the operating temperature of the CRESST detectors has been installed at the Maier-Leibnitz-Accelerator Laboratory in Garching and is presently being commissioned. The design of this neutron scattering facility is such that it can also be used for other target materials, e.g. $\mathrm{ZnWO_4}$, $\mathrm{PbWO_4}$ and others as foreseen in the framework of the future multitarget tonne-scale experiment EURECA (European Underground Rare Event Calorimeter Array).

astro-ph↗