Measurement of $\eta\to\pi^{0}\gamma\gamma$ branching fraction with the KLOE detector

We present a measurement of the radiative decay $\eta\to\pi^0\gamma\gamma$ using 82 million $\eta$ mesons produced in $e^+e^-\to\phi\to\eta\gamma$ process at the Frascati $\phi$-factory DA$\Phi$NE. From the data analysis $1246\pm133$ signal events are observed. By normalising the signal to the well-known $\eta\to3\pi^0$ decay the branching fraction ${\cal B}(\eta\to\pi^0\gamma\gamma)$ is measured to be $(0.98\pm 0.11_\text{stat}\pm 0.14_\text{syst})\times10^{-4}$. This result agrees with a preliminary KLOE measurement, but is twice smaller than the present world average. Results for $d\Gamma(\eta\to\pi^0\gamma\gamma)/dM^2(\gamma\gamma)$ are also presented and compared with latest theory predictions.

hep-ex

TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix

We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of analytical functions, uniquely defined for each pair of plastic scintillator strips used for the detection. A realistic resolution model (RM) in detector space is derived from fitting the Monte Carlo simulated emissions and detections of annihilation photons on oblique transverse planes. Additional kernels embedded in SRM account for TOF, parallax effect and axial smearing. The algorithm was tested on datasets, simulated in GATE for the NEMA IEC and static XCAT phantoms inside a 24-module 2-layer TB J-PET. Compared to the reference TOF MLEM with none or a shift-invariant RM, an improvement was observed, as evaluated by the analysis of image quality, difference images and ground truth metrics. We also reconstructed the data with additive contributions, pre-filtered geometrically and with non-TOF scatter correction applied. Despite some deterioration, the obtained results still capitalise on the realistic RM with better edge preservation and superior ground truth metrics. The envisioned prospects of the TOF MLEM with analytical SRM include its application in multi-photon imaging and further upgrade to account for the non-collinearity, positron range and other factors.

physics.med-ph

Investigation of Novel Preclinical Total Body PET Designed With J-PET Technology:A Simulation Study

The growing interest in human-grade total body positron emission tomography (PET) systems has also application in small animal research. Due to the existing limitations in human-based studies involving drug development and novel treatment monitoring, animal-based research became a necessary step for testing and protocol preparation. In this simulation-based study two unconventional, cost-effective small animal total body PET scanners (for mouse and rat studies) have been investigated in order to inspect their feasibility for preclinical research. They were designed with the novel technology explored by the Jagiellonian-PET (J-PET) Collaboration. Two main PET characteristics: sensitivity and spatial resolution were mainly inspected to evaluate their performance. Moreover, the impact of the scintillator dimension and time-of-flight on the latter parameter was examined in order to design the most efficient tomographs. The presented results show that for mouse TB J-PET the achievable system sensitivity is equal to 2.35% and volumetric spatial resolution to 9.46 +- 0.54 mm3, while for rat TB J-PET they are equal to 2.6% and 14.11 +- 0.80 mm3, respectively. Furthermore, it was shown that the designed tomographs are almost parallax-free systems, hence, they resolve the problem of the acceptance criterion tradeoff between enhancing spatial resolution and reducing sensitivity.

physics.med-ph

Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner

Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpose of the performed measurements is to compare the transparency of long plastic scintillators with dimensions 6 mm x 24 mm x 1000 mm and with all surfaces polished. Six different types of commercial, general purpose, blue-emitting plastic scintillators with low attenuation of visible light were tested, namely: polyvinyl toluene-based BC-408, EJ-200, RP-408, and polystyrene-based Epic, SP32 and UPS-923A. For determination of the best type of plastic scintillator for totalbody Jagiellonian positron emission tomograph (TB-J-PET) construction, emission and transmission spectra, and technical attenuation length (TAL) of blue light-emitting by the scintillators were measured and compared. The TAL values were determined with the use of UV lamp as excitation source, and photodiode as light detector. Emission spectra of investigated scintillators have maxima in the range from 420 nm to 429 nm. The BC-408 and EJ-200 have the highest transmittance values of about 90% at the maximum emission wavelength measured through a 6 mm thick scintillator strip and the highest technical attenuation length reaching about 2000 mm, allowing assembly of long detection modules for time-of-flight (TOF) J-PET scanners. Influence of the 6 mm x 6 mm, 12 mm x 6 mm, 24 mm x 6 mm cross-sections of the 1000 mm long EJ-200 plastic scintillator on the TAL and signal intensity was measured. The highest TAL value was determined for samples with 24 mm x 6 mm cross-section.

physics.ins-det

Feasibility studies for imaging e$^{+}$e$^{-}$ annihilation with modular multi-strip detectors

Studies based on imaging the annihilation of the electron (e$^{-}$) and its antiparticle positron (e$^{+}$) open up several interesting applications in nuclear medicine and fundamental research. The annihilation process involves both the direct conversion of e$^{+}$e$^{-}$ into photons and the formation of their atomically bound state, the positronium atom (Ps), which can be used as a probe for fundamental studies. With the ability to produce large quantities of Ps, manipulate them in long-lived Ps states, and image their annihilations after a free fall or after passing through atomic interferometers, this purely leptonic antimatter system can be used to perform inertial sensing studies in view of a direct test of Einstein equivalence principle. It is envisioned that modular multistrip detectors can be exploited as potential detection units for this kind of studies. In this work, we report the results of the first feasibility study performed on a e$^{+}$ beamline using two detection modules to evaluate their reconstruction performance and spatial resolution for imaging e$^{+}$e$^{-}$ annihilations and thus their applicability for gravitational studies of Ps.

physics.ins-det

Measurement of the $K_S \to πe ν$ branching fraction with the KLOE experiment

The branching fraction for the decay $K_S \to πe ν$ has been measured with a sample of 300 million $K_S$ mesons produced in $ϕ\to K_L K_S$ decays recorded by the KLOE experiment at the DA$Φ$NE $e^+e^-$ collider. Signal decays are selected by a boosted decision tree built with kinematic variables and time-of-flight measurements. Data control samples of $K_L \to πe ν$ decays are used to evaluate signal selection efficiencies. A fit to the reconstructed electron mass distribution finds 49647$\pm$316 signal events. Normalising to the $K_S \to π^+π^-$ decay events the result for the branching fraction is $\mathcal{B}(K_S \to πe ν) = (7.211 \pm 0.046_{\rm stat} \pm 0.052_{\rm syst}) \times10^{-4}$. The combination with our previous measurement gives $\mathcal{B}(K_S \to πe ν) = (7.153 \pm 0.037_{\rm stat} \pm 0.043_{\rm syst}) \times10^{-4}$. From this value we derive $f_+(0)|V_{us}| = 0.2170 \pm 0.009$.

hep-ex

J-PET detection modules based on plastic scintillators for performing studies with positron and positronium beams

The J-PET detector, which consists of inexpensive plastic scintillators, has demonstrated its potential in the study of fundamental physics. In recent years, a prototype with 192 plastic scintillators arranged in 3 layers has been optimized for the study of positronium decays. This allows performing precision tests of discrete symmetries (C, P, T) in the decays of positronium atoms. Moreover, thanks to the possibility of measuring the polarization direction of the photon based on Compton scattering, the predicted entanglement between the linear polarization of annihilation photons in positronium decays can also be studied. Recently, a new J-PET prototype was commissioned, based on a modular design of detection units. Each module consists of 13 plastic scintillators and can be used as a stand-alone, compact and portable detection unit. In this paper, the main features of the J-PET detector, the modular prototype and their applications for possible studies with positron and positronium beams are discussed. Preliminary results of the first test experiment performed on two detection units in the continuous positron beam recently developed at the Antimatter Laboratory (AML) of Trento are also reported.

physics.ins-det

Direct tests of T, CP, CPT symmetries in transitions of neutral K mesons with the KLOE experiment

Tests of the T, CP and CPT symmetries in the neutral kaon system are performed by the direct comparison of the probabilities of a kaon transition process to its symmetry-conjugate. The exchange of in and out states required for a genuine test involving an anti-unitary transformation implied by time-reversal is implemented exploiting the entanglement of $K^0\bar{K}{}^0$ pairs produced at a $ϕ$-factory. A data sample collected by the KLOE experiment at DA$Φ$NE corresponding to an integrated luminosity of about 1.7 fb$^{-1}$ is analysed to study the $Δ$t distributions of the $ϕ\to K_{S}K_{L}\to π^+π^- \: π^{\pm}e^{\mp}ν$ and $ϕ\to K_{S}K_{L}\to π^{\pm}e^{\mp}ν\: 3π^0$ processes, with $Δ$t the difference of the kaon decay times. A comparison of the measured $Δ$t distributions in the asymptotic region $Δt \gg τ_{S}$ allows to test for the first time T and CPT symmetries in kaon transitions with a precision of few percent, and to observe CP violation with this novel method.

hep-ex

Precision tests of Quantum Mechanics and CPT symmetry with entangled neutral kaons at KLOE

The quantum interference between the decays of entangled neutral kaons is studied in the process $ϕ\rightarrow K_S K_L \rightarrowπ^+π^-π^+π^-$, which exhibits the characteristic Einstein--Podolsky--Rosen correlations that prevent both kaons to decay into $π^+π^-$ at the same time. This constitutes a very powerful tool for testing at the utmost precision the quantum coherence of the entangled kaon pair state, and to search for tiny decoherence and CPT violation effects, which may be justified in a quantum gravity framework. The analysed data sample was collected with the KLOE detector at DA$Φ$NE, the Frascati $ϕ$-factory, and corresponds to an integrated luminosity of about 1.7 fb$^{-1}$, i.e. to about $1.7 \times 10^9$ $ϕ\rightarrow K_S K_L$ decays produced. From the fit of the observed $Δt$ distribution, being $Δt$ the difference of the kaon decay times, the decoherence and CPT violation parameters of various phenomenological models are measured with a largely improved accuracy with respect to previous analyses. The results are consistent with no deviation from quantum mechanics and CPT symmetry, while for some parameters the precision reaches the interesting level at which -- in the most optimistic scenarios -- quantum gravity effects might show up. They provide the most stringent limits up to date on the considered models.

hep-ex

Optimisation of the event-based TOF filtered back-projection for online imaging in total-body J-PET

We perform a parametric study of the newly developed time-of-flight (TOF) image reconstruction algorithm, proposed for the real-time imaging in total-body Jagiellonian PET (J-PET) scanners. The asymmetric 3D filtering kernel is applied at each most likely position of electron-positron annihilation, estimated from the emissions of back-to-back $γ$-photons. The optimisation of its parameters is studied using Monte Carlo simulations of a 1-mm spherical source, NEMA IEC and XCAT phantoms inside the ideal J-PET scanner. The combination of high-pass filters which included the TOF filtered back-projection (FBP), resulted in spatial resolution, 1.5 $\times$ higher in the axial direction than for the conventional 3D FBP. For realistic $10$-minute scans of NEMA IEC and XCAT, which require a trade-off between the noise and spatial resolution, the need for Gaussian TOF kernel components, coupled with median post-filtering, is demonstrated. The best sets of 3D filter parameters were obtained by the Nelder-Mead minimisation of the mean squared error between the resulting and reference images. The approach allows training the reconstruction algorithm for custom scans, using the IEC phantom, when the temporal resolution is below 50 ps. The image quality parameters, estimated for the best outcomes, were systematically better than for the non-TOF FBP.

physics.med-ph

The J-PET detector -- a tool for precision studies of ortho-positronium decays

The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measurement of the time, position, polarization and energy deposited by photons in the scintillators, in contrast to studies conducted so far with crystal and semiconductor based detection systems where the key selection of events is based on the measurement of the photons energies. In this article we show that the J-PET tomograph system is capable of exclusive measurements of the decays of ortho-positronium atoms. We present the first positronium production results, its lifetime distribution measurements and discuss estimation of the influence of various background sources. The tomograph s performance demonstrated here makes it suitable for precision studies of positronium decays including entanglement of the final state photons, positron annihilation lifetime spectroscopy plus molecular imaging diagnostics.

physics.ins-det

Upper limit on the $η\toπ^{+}π^{-}$ branching fraction with the KLOE experiment

Based on an integrated luminosity of 1.61 fb$^{-1}$ $e^+e^-$ collision data collected with the KLOE detector at DA$Φ$NE, the Frascati $ϕ$-factory, a search for the $P$- and $CP$-violating decay $η\toπ^{+}π^{-}$ has been performed. Radiative $ϕ\toηγ$ decay is exploited to access the $η$ mesons. No signal is observed in the $π^{+}π^{-}$ invariant mass spectrum, and the upper limit on the branching fraction at 90\% confidence level is determined to be ${\mathcal B}(η\toπ^{+}π^{-})<4.9\times10^{-6}$, which is approximately three times smaller than the previous KLOE result. From the combination of these two measurements we get ${\mathcal B}(η\toπ^{+}π^{-}) < 4.4\times10^{-6}$ at 90\% confidence level.

hep-ex

Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view

Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a full-scale J-PET tomograph from long strips of plastic scintillators, a 24-strip prototype was built and tested. The prototype consists of detection modules arranged axially forming a cylindrical diagnostic chamber with the inner diameter of 360 mm and the axial field-of-view of 300 mm. Promising perspectives for a low-cost construction of a total-body PET scanner are opened due to an axial arrangement of strips of plastic scintillators, wchich have a small light attenuation, superior timing properties, and the possibility of cost-effective increase of the axial field-of-view. The presented prototype comprises dedicated solely digital front-end electronic circuits and a triggerless data acquisition system which required development of new calibration methods including time, thresholds and gain synchronization. The system and elaborated calibration methods including first results of the 24-module J-PET prototype are presented and discussed. The achieved coincidence resolving time equals to CRT = 490 $\pm$ 9 ps. This value can be translated to the position reconstruction accuracy $σ(Δl) =$ 18 mm which is fairly position-independent.

physics.ins-det

Hit-time and hit-position reconstruction in strips of plastic scintillators using multi-threshold readouts

In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This research is motivated by the recent development of the positron emission tomography scanners based on plastic scintillators. The proposed method constitutes a new way of signal processing in Multi-Voltage-Technique. It is based on the determination of the degree of similarity between the registered signals and the synchronized model signals stored in a library. The library was established for a set of well defined hit-positions along the length of the scintillator. The Mahalanobis distance was used as a measure of similarity between the two compared signals. The method was validated on the experimental data measured using two-strips J-PET prototype with dimensions of 5x9x300 mm$^3$. The obtained Time-of-Flight (TOF) and spatial resolutions amount to 325~ps (FWHM) and 25~mm (FWHM), respectively. The TOF resolution was also compared to the results of an analogous study done using Linear Fitting method. The best TOF resolution was obtained with this method at four pre-defined threshold levels which was comparable to the resolution achieved from the Mahalanobis distance at two pre-defined threshold levels. Although the algorithm of Linear Fitting method is much simpler to apply than the Mahalanobis method, the application of the Mahalanobis distance requires a lower number of applied threshold levels and, hence, decreases the costs of electronics used in PET scanner.

physics.ins-det

Measurement of the branching fraction for the decay $K_S \to πμν$ with the KLOE detector

Based on a sample of 300 million $K_S$ mesons produced in $ϕ\to K_L K_S$ decays recorded by the KLOE experiment at the DA$Φ$NE $e^+e^-$ collider we have measured the branching fraction for the decay $K_S \to πμν$. The $K_S$ mesons are identified by the interaction of $K_L$ mesons in the detector. The $K_S \to πμν$ decays are selected by a boosted decision tree built with kinematic variables and by a time-of-flight measurement. Signal efficiencies are evaluated with data control samples of $K_L \to πμν$ decays. A fit to the reconstructed muon mass distribution finds $7223 \pm 180$ signal events. Normalising to the $K_S \to π^+ π^-$ decay events the result for the branching fraction is $\mathcal{B}(K_S \to πμν) = (4.56 \pm 0.11_{\rm stat} \pm 0.17_{\rm syst})\times10^{-4}$.

hep-ex

Estimating relationship between the Time Over Threshold and energy loss by photons in plastic scintillators used in the J-PET scanner

Time-Over-Threshold (TOT) technique is being used widely due to its implications in developing the multi channel readouts mainly when fast signal processing is required. Using TOT technique as a measure of energy loss instead of charge integration methods significantly reduces the signals readout cost by combining the time and energy information. Therefore, this approach can potentially be used in J-PET tomograph which is build from plastic scintillators characterized by fast light signals. The drawback in adopting this technique is lying in the non-linear correlation between input energy loss and TOT of the signal. The main motivation behind this work is to develop the relationship between TOT and energy loss and validate it with the J-PET tomograph. The experiment was performed using the $^{22}$Na beta emitter source placed in the center of the J-PET tomograph. One can obtain primary photons of two different energies: 511 keV photon from the annihilation of positron (direct annihilation or through the formation of para-Positronim atom or pick-off process of ortho-Positronium atoms), and 1275 keV prompt photon. This allows to study the correlation between TOT values and energy loss for energy range up to 1000 keV. As the photon interacts dominantly via Compton scattering inside the plastic scintillator, there is no direct information of primary photon energy. However, using the J-PET geometry one can measure the scattering angle of the interacting photon. Since, $^{22}$Na source emits photons of two different energies, it is required to know unambiguously the energy of incident photons and its corresponding scattering angle for the estimation of energy deposition. In this work, the relationship between Time Over Threshold and energy loss by interacting photons inside the plastic scintillators used in J-PET scanner is established for a energy deposited range 100-1000 keV

physics.ins-det

Performance assessment of the 2$γ$ positronium imaging with the total-body PET scanners

In living organisms the positron-electron annihilation (occurring during the PET imaging) proceeds in about 30% via creation of a metastable ortho-positronium atom. In the tissue, due to the pick-off and conversion processes, over 98% of ortho-positronia annihilate into two 511~keV photons. In this article we assess the feasibility for reconstruction of the mean ortho-positronium lifetime image based on annihilations into two photons. The main objectives of this work include: (i) estimation of the sensitivity of the total-body PET scanners for the ortho-positronium mean lifetime imaging using $2γ$ annihilations, and (ii) estimation of the spatial and time resolution of the ortho-positronium image as a function of the coincidence resolving time (CRT) of the scanner. Simulations are conducted assuming that radiopharmaceutical is labelled with $^{44}Sc$ isotope emitting one positron and one prompt gamma. The image is reconstructed on the basis of triple coincidence events. The ortho-positronium lifetime spectrum is determined for each voxel of the image. Calculations were performed for cases of total-body detectors build of (i) LYSO scintillators as used in the EXPLORER PET, and (ii) plastic scintillators as anticipated for the cost-effective total-body J-PET scanner. To assess the spatial and time resolution the three cases were considered assuming that CRT is equal to 140ps, 50ps and 10ps. The estimated total-body PET sensitivity for the registration and selection of image forming triple coincidences is larger by a factor of 12.2 (for LYSO PET) and by factor of 4.7 (for plastic PET) with respect to the sensitivity for the standard $2γ$ imaging by LYSO PET scanners with AFOV=20cm.

physics.ins-det

Simulation studies of annihilation-photon's polarisation via Compton scattering with the J-PET tomograph

J-PET is the first positron-emission tomograph (PET) constructed from plastic scintillators. It was optimized for the detection of photons from electron-positron annihilation. Such photons, having an energy of 511 keV, interact with electrons in plastic scintillators predominantly via the Compton effect. Compton scattering is at most probable at an angle orthogonal to the electric field vector of the interacting photon. Thus registration of multiple photon scatterings with J-PET enables to determine the polarization of the annihilation photons. In this contribution we present estimates on the physical limitation in the accuracy of the polarization determination of $511$~keV photons with the J-PET detector.

physics.ins-det