SearcharxivSearch

arXiv subjects

A. Golossanov

Publications and source records attributed to A. Golossanov.

15 recordsLinked to original sources

The MuFusE Large-Volume Diamond Anvil Cell for Exploring Muon-Catalyzed Fusion at Higher Pressures and Temperatures

A new large-volume diamond anvil cell (DAC) has been developed for the Muon-catalyzed Fusion ($\mu$CF) Experiment (MuFusE), enabling the compression and heating of deuterium-tritium (d-t) mixtures to pressures and temperatures needed to advance $\mu$CF research. The MuFusE DAC achieves the large sample volumes necessary for high-precision fusion measurements while integrating cryogenic loading, all-metal sealing, and flexible bellows to maintain a secure environment during cell compression. Combined with remote pneumatic actuation and secondary containment, the DAC safely managed a 25 Ci tritium inventory while providing a clear optical path for in situ measurements of sample pressure and composition via laser spectroscopy. Utilizing 5 mm diameter diamond anvils oriented in the path of a high-intensity muon beam, the apparatus achieved a stable sample volume of 19.2 mm$^3$ at liquid density, pressures up to 933 MPa and temperatures up to 400 K - benchmarks that significantly exceed previously reported limits for static d-t targets.

physics.ins-det

The MUSE Target Chamber Post Veto

The Muon Scattering Experiment (MUSE) was developed to address the proton radius puzzle through simultaneous electron-proton and muon-proton scattering using the Paul Scherrer Institute's PiM1 secondary beamline. MUSE uses a large-solid-angle, non-magnetic spectrometer to detect beam particles scattering from a liquid hydrogen cell contained within a vacuum chamber. Due to the large scattering windows, the structural integrity of the chamber is supported by posts located at small scattering angles. While out of the acceptance, particles in the tails of the beam distribution can strike these posts, causing a significant trigger background. We describe the design and performance of the Target Chamber Post Veto (TCPV) detector installed inside the vacuum chamber to remove these background events at the trigger level.

physics.ins-det

The MUSE Beamline Calorimeter

The MUon Scattering Experiment (MUSE) was motivated by the proton radius puzzle arising from the discrepancy between muonic hydrogen spectroscopy and electron-proton measurements. The MUSE physics goals also include testing lepton universality, precisely measuring two-photon exchange contribution, and testing radiative corrections. MUSE addresses these physics goals through simultaneous measurement of high precision cross sections for electron-proton and muon-proton scattering using a mixed-species beam. The experiment will run at both positive and negative beam polarities. Measuring precise cross sections requires understanding both the incident beam energy and the radiative corrections. For this purpose, a lead-glass calorimeter was installed at the end of the beam line in the MUSE detector system. In this article we discuss the detector specifications, calibration and performance. We demonstrate that the detector performance is well reproduced by simulation, and meets experimental requirements.

physics.ins-det

Characterization of Muon and Electron Beams in the Paul Scherrer Institute PiM1 Channel for the MUSE Experiment

The MUon Scattering Experiment, MUSE, at the Paul Scherrer Institute, Switzerland, investigates the proton charge radius puzzle, lepton universality, and two-photon exchange, via simultaneous measurements of elastic muon-proton and electron-proton scattering. The experiment uses the PiM1 secondary beam channel, which was designed for high precision pion scattering measurements. We review the properties of the beam line established for pions. We discuss the production processes that generate the electron and muon beams, and the simulations of these processes. Simulations of the $π$/$μ$/$e$ beams through the channel using TURTLE and G4beamline are compared. The G4beamline simulation is then compared to several experimental measurements of the channel, including the momentum dispersion at the IFP and target, the shape of the beam spot at the target, and timing measurements that allow the beam momenta to be determined. We conclude that the PiM1 channel can be used for high precision $π$, $μ$, and $e$ scattering.

physics.ins-det

A Measurement of the Branching Ratio of $π^0$ Dalitz Decay using $K_L \rightarrow π^0π^0π^0$ Decays

We present a measurement of $B(π^0 \rightarrow e^+e^- γ)/B(π^0 \rightarrow γγ)$, the Dalitz branching ratio, using data taken in 1999 by the E832 KTeV experiment at Fermi National Accelerator Laboratory. We use neutral pions from fully reconstructed $K_L$ decays in flight; the measurement is based on about 60 thousand $K_L \rightarrow π^0π^0π^0 \rightarrow γγ~γγ~e^+e^-γ$ decays. We normalize to $K_L \rightarrow π^0π^0π^0 \rightarrow 6γ$ decays. We find $B(π^0 \rightarrow e^+e^- γ)/B(π^0 \rightarrow γγ)$ $(m_{e^+e^-}$ > 15 MeV/$c^2)$ = $[3.920 \pm 0.016(stat) \pm 0.036 (syst)] \times 10^{-3}$. Using the Mikaelian and Smith prediction for the $e^+e^-$ mass spectrum, we correct the result to the full $e^+e^-$ mass range. The corrected result is $B(π^0 \rightarrow e^+e^- γ)/B(π^0 \rightarrow γγ) = [1.1559 \pm 0.0047(stat) \pm 0.0106 (syst)]$%. This result is consistent with previous measurements and the uncertainty is a factor of three smaller than any previous measurement.

hep-ex

A Liquid Hydrogen Target for the MUSE Experiment at PSI

A 280 ml liquid hydrogen target has been constructed and tested for the MUSE experiment at PSI to investigate the proton charge radius via simultaneous measurement of elastic muon-proton and elastic electron-proton scattering. To control systematic uncertainties at a sub-percent level, strong constraints were put on the amount of material surrounding the target and on its temperature stability. The target cell wall is made of $120\,μ$m-thick Kapton, while the beam entrance and exit windows are made of $125\,μ$m-thick aluminized Kapton. The side exit windows are made of Mylar laminated on aramid fabric with an areal density of $368\,$g/m$^2$. The target system was successfully operated during a commissioning run at PSI at the end of 2018. The target temperature was stable at the 0.01 K level. This suggests a density stability at the $0.02\,$% level, which is about a factor of ten better than required.

physics.ins-det

Technical Design Report for the Paul Scherrer Institute Experiment R-12-01.1: Studying the Proton "Radius" Puzzle with μp Elastic Scattering

The difference in proton radii measured with $μp$ atoms and with $ep$ atoms and scattering remains an unexplained puzzle. The PSI MUSE proposal is to measure $μp$ and $e p$ scattering in the same experiment at the same time. The experiment will determine cross sections, two-photon effects, form factors, and radii independently for the two reactions, and will allow $μp$ and $ep$ results to be compared with reduced systematic uncertainties. These data should provide the best test of lepton universality in a scattering experiment to date, about an order of magnitude improvement over previous tests. Measuring scattering with both particle polarities will allow a test of two-photon exchange at the sub-percent level, about a factor of four improvement on uncertainties and over an order of magnitude more data points than previous low momentum transfer determinations, and similar to the current generation of higher momentum transfer electron experiments. The experiment has the potential to demonstrate whether the $μp$ and $ep$ interactions are consistent or different, and whether any difference results from novel physics or two-photon exchange. The uncertainties are such that if the discrepancy is real it should be confirmed with $\approx$5$σ$ significance, similar to that already established between the regular and muonic hydrogen Lamb shift.

physics.ins-det

Search for the Rare Decays KL->pi0pi0mu+mu- and KL->pi0pi0X0->pi0pi0mu+mu-

The KTeV E799 experiment has conducted a search for the rare decays KL->pi0pi0mu+mu- and KL->pi0pi0X0->pi0pi0mu+mu-, where the X0 is a possible new neutral boson that was reported by the HyperCP experiment with a mass of (214.3 pm 0.5) MeV/c^{2}. We find no evidence for either decay. We obtain upper limits of Br(KL->pi0pi0X0->pi0pi0mu+mu-) < 1.0 x 10^{-10} and Br(KL->pi0pi0mu+mu-) < 9.2 x 10^{-11} at the 90% confidence level. This result rules out the pseudoscalar X0 as an explanation of the HyperCP result under the scenario that the \bar{d}sX0 coupling is completely real.

hep-ex

Precise Measurements of Direct CP Violation, CPT Symmetry, and Other Parameters in the Neutral Kaon System

We present precise tests of CP and CPT symmetry based on the full dataset of K to pipi decays collected by the KTeV experiment at Fermi National Accelerator Laboratory during 1996, 1997, and 1999. This dataset contains 16 million K to 2pi0 and 69 million K to pi+pi- decays. We measure the direct CP violation parameter Re(epsilon'/epsilon) = (19.2 pm 2.1)x10-4. We find the KL-KS mass difference Deltam = (5270 pm 12)x10^6 hbar/s and the KS lifetime tauS = (89.62 pm 0.05)x10-12 s. We also measure several parameters that test CPT invariance. We find the difference between the phase of the indirect CP violation parameter, epsilon, and the superweak phase, phi_epsilon - phi_SW = (0.40 pm 0.56) degrees. We measure the difference of the relative phases between the CP violating and CP conserving decay amplitudes for K to pi+pi- (phi+-) and for K to 2pi0 (phi00), Delta phi = (0.30 pm 0.35) degrees. From these phase measurements, we place a limit on the mass difference between K0 and K0bar, DeltaM < 4.8 x 10-19 GeV/c^2 at 95% C.L. These results are consistent with those of other experiments, our own earlier measurements, and CPT symmetry.

hep-ex

Search for the Rare Decay K_{L}\toπ^{0}π^{0}γ

The KTeV E799 experiment has conducted a search for the rare decay $K_{L}\toπ^{0}π^{0}γ$ via the topology $K_{L}\toπ^{0}π^{0}_Dγ$ (where $π^0_D\toγe^+e^-$). Due to Bose statistics of the $π^0$ pair and the real nature of the photon, the $K_{L}\toπ^{0}π^{0}γ$ decay is restricted to proceed at lowest order by the CP conserving direct emission (DE) of an E2 electric quadrupole photon. The rate of this decay is interesting theoretically since chiral perturbation theory predicts that this process vanishes at level $O(p^4)$. Therefore, this mode probes chiral perturbation theory at $O(p^6)$. In this paper we report a determination of an upper limit of $2.43\times 10^{-7}$ (90% CL) for $K_{L}\toπ^{0}π^{0}γ$. This is approximately a factor of 20 lower than previous results.

hep-ex

Observation of the Decay Xi^0 --> Sigma^+ mu^- nu(bar)

The Xi^0 muon semi-leptonic decay has been observed for the first time with nine identified events using the KTeV beam line and detector at Fermilab. The decay is normalized to the Xi^0 beta decay mode and yields a value for the ratio of decay rates of $(1.8^{+0.7}_{-0.5}(stat.)\pm0.2(syst.))\times 10^{-2}$. This is in agreement with the SU(3) flavor symmetric quark model.

hep-ex

Final Results from the KTeV Experiment on the Decay KL -> pi0 gamma gamma

We report on a new measurement of the branching ratio B(KL->pi0 gamma gamma)using the KTeV detector. We reconstruct 1982 events with an estimated background of 608, that results in B(KL -> pi0 gamma gamma) = (1.29 +/- 0.03(stat) +/- 0.05(syst)) x 10**-6. We also measure the parameter, aV, which characterizes the strength of vector meson exchange terms in this decay. We find aV = -0.31 +/- 0.05(stat) +/- 0.07(syst). These results utilize the full KTeV data set collected from 1997 to 2000 and supersede earlier KTeV measurements of the branching ratio and aV.

hep-ex

Determination of the Parity of the Neutral Pion via the Four-Electron Decay

We present a new determination of the parity of the neutral pion via the double Dalitz decay pi^0 -> e+ e- e+ e-. Our sample, which consists of 30511 candidate decays, was collected from K_L -> pi0 pi0 pi0 decays in flight at the KTeV-E799 experiment at Fermi National Accelerator Laboratory. We confirm the negative pi^0 parity, and place a limit on scalar contributions to the pi^0 -> e+ e- e+ e- decay amplitude of less than 3.3% assuming CPT conservation. The pi^0 gamma* gamma* form factor is well described by a momentum-dependent model with a slope parameter fit to the final state phase space distribution. Additionally, we have measured the branching ratio of this mode to be B(pi^0 -> e+ e- e+ e-) = (3.26 +- 0.18) x 10^(-5).

hep-ex

Measurement of the Decay KL -> pi0 e+ e- gamma

We report on a new measurement of the branching ratio B(KL -> pi0 e+ e- gamma) using the KTeV detector. This analysis uses the full KTeV data set collected from 1997 to 2000. We reconstruct 139 events over a background of 14, which results in B(KL -> pi0 e+ e- gamma) = (1.62 +/- 0.14 (stat) +/- 0.09 (syst)) x 10^{-8}. This result supersedes the earlier KTeV measurement of this branching ratio.

hep-ex

Measurements of the Branching Fractions and Decay Distributions for KL->πμνγand KL->πeνγ

We present measurements of R_Kl3rad = Gamma(KL->π\ellνγ; Egcm > 10 MeV)/Gamma(KL->π\ellν), where ell = mu or e, and Egcm is the photon energy in the kaon rest frame. These measurements are based on KL decays collected in 1997 by the KTeV (E832) experiment at Fermilab. With samples of 1385 KL->πμνγand 14221 KL->π\eνγcandidates, we find R_Km3rad = (0.530 +- 0.019)% and R_Ke3rad = (4.942 +- 0.062)%. We also examine distributions of photon energy and lepton-photon angle.

hep-ex