Searcharxiv⌕ Search

arXiv subjects

A. Grassellino

Publications and source records attributed to A. Grassellino.

At least 37 records · Page 2Linked to original sources

Higgs-Energy LEptoN (HELEN) Collider based on advanced superconducting radio frequency technology

This Snowmass 2021 contributed paper discusses a Higgs-Energy LEptoN (HELEN) $e^+e^-$ linear collider based on advances superconducting radio frequency technology. The proposed collider offers cost and AC power savings, smaller footprint (relative to the ILC), and could be built at Fermilab with an Interaction Region within the site boundaries. After the initial physics run at 250 GeV, the collider could be upgraded either to higher luminosity or to higher (up to 500 GeV) energies. If the ILC could not be realized in Japan in a timely fashion, the HELEN collider would be a viable option to build a Higgs factory in the U.S.

physics.acc-ph↗

Q-factor optimization for high-beta 650 MHz cavities for PIP-II

High Q-factors are of utmost importance to minimize losses of superconducting radio-frequency cavities deployed in continuous wave particle accelerators. This study elucidates the surface treatment that can maximize the Q-factors in high-beta 650 MHz elliptical niobium cavities. State-of-the-art surface treatments are applied in many single-cell cavities, and surface resistance studies are performed to understand the microwave dissipation at this unexplored frequency. The nitrogen doping treatment is confirmed to be necessary to maximize the Q-factors at medium RF fields. We applied this treatment in five-cell high-beta 650 MHz cavities and demonstrated that extremely high Q-factors were obtained at medium RF fields with this treatment. We also demonstrated that adding a cold electropolishing step after N-doping is crucial to push the quench field of multicell cavities to higher gradients.

physics.acc-ph↗

LCLS-II-HE verification cryomodule high gradient performance and quench behavior

An 8-cavity, 1.3 GHz, LCLS-II-HE cryomodule was assembled and tested at Fermilab to verify performance before the start of production. Its cavities were processed with a novel nitrogen doping treatment to improve gradient performance. The cryomodule was tested with a modified protocol to process sporadic quenches, which were observed in LCLS-II production cryomodules and are attributed to multipacting. Dedicated vertical test experiments support the attribution to multipacting. The verification cryomodule achieved an acceleration voltage of 200 MV in continuous wave mode, corresponding to an average accelerating gradient of 24.1 MV/m, significantly exceeding the specification of 173 MV. The average Q0 (3.0x10^10) also exceeded its specification (2.7x10^10). After processing, no field emission was observed up to the maximum gradient of each cavity. This paper reviews the cryomodule performance and discusses operational issues and mitigations implemented during the several month program.

physics.acc-ph↗

Three-dimensional superconducting resonators at $T < 20$ mK with the photon lifetime up to $τ=2$ seconds

Very high quality factor superconducting radio frequency cavities developed for accelerators can enable fundamental physics searches with orders of magnitude higher sensitivity, as well as offer a path to a 1000-fold increase in the achievable coherence times for cavity-stored quantum states in the 3D circuit QED architecture. Here we report the first measurements of multiple accelerator cavities of $f_0=$1.3, 2.6, 5 GHz resonant frequencies down to temperatures of about 10~mK and field levels down to a few photons, which reveal record high photon lifetimes up to 2 seconds, while also further exposing the role of the two level systems (TLS) in the niobium oxide. We also demonstrate how the TLS contribution can be greatly suppressed by the vacuum heat treatments at 340-450$^\circ$C.

quant-ph↗

Impact of high Q on ILC250 upgrade for record luminosities and path toward ILC380

In this paper, we address the possibility of upgrading the ILC250 luminosity to $8.1 \times 10^{34}$, so that with the polarization feature, the effective luminosity will be $2.0 \times 10^{35}$ to compete with the FCC-ee luminosity and two detectors. The additional cost of the higher luminosity option will be about 2.2 B ILCU. The total cost for the ILC high luminosity machine will therefore be about 7.7 B versus FCC-ee 10.5 B. The AC power (267 MW) to operate the ILC luminosity upgrade will also be less than the AC power for FCC-ee (300 MW). Even with a modest quality factor Q of $1 \times 10^{10}$ for SRF cavities, the total cost of the upgrade will be 2.5 B ILCU additional over ILC250 baseline. We expect that, if approved, ILC250 will first be built at the baseline luminosity, operated for many years at this luminosity, and later upgraded to the high luminosity option. A significant part (RF power and cryo-power) of the additional cost for the luminosity upgrade overlaps with the expected additional costs for anticipated energy upgrade paths. A second ILC upgrade discussed in this paper will be to the higher energy Top Factory at 380 GeV. We also estimate the additional cost of this upgrade (1.5 B ILCU).

physics.acc-ph↗

Ultra-Low Surface Resistance via Vacuum Heat Treatment of Superconducting Radiofrequency Cavities

We report on an effort to improve the performance of superconducting radiofrequency cavities by the use of heat treatment in a temperature range sufficient to dissociate the natural surface oxide. We find that the residual resistance is significantly decreased, and we find an unexpected reduction in the BCS resistance. Together these result in extremely high quality factor values at relatively large accelerating fields Eacc ~20 MV/m: Q0 of 3-4x10^11 at <1.5 K and Q0 ~5x10^10 at 2.0 K. In one cavity, measurements of surface resistance versus temperature showed an extremely small residual resistance of just 0.63+/-0.06 nOhms at 16 MV/m. SIMS measurements confirm that the oxide was significantly dissociated, but they also show the presence of nitrogen after heat treatment. We also present studies of surface oxidation via exposure to air and to water, as well as the effects of very light surface removal via HF rinse. The possibilities for applications and the planned future development are discussed.

physics.acc-ph↗

Low RF power plasma ignition and detection for in-situ cleaning of 1.3 GHz 9-cell cavities

Superconducting Radio Frequency (SRF) cavities performance preservation is crucial, from vertical test to accelerator operation. Field Emission (FE) is still one of the performance limiting factors to overcome and plasma cleaning has been proven successful by the Spallation Neutron Source (SNS), in cleaning field emitters and increasing the work function of Nb. A collaboration has been established between Fermi National Accelerator Laboratory (FNAL), SLAC National Accelerator Laboratory and Oak Ridge National Laboratory (ORNL) with the purpose of applying plasma processing to the Linac Coherent Light Source-II (LCLS-II) cavities, in order to minimize and overcome field emission without affecting the high Q of nitrogen-doped cavities. The cleaning for LCLS-II will follow the same plasma composition adopted at SNS, which allows in-situ processing of cavities installed in cryomodules from hydrocarbon contaminants. A novel method for plasma ignition has been developed at FNAL: a plasma glow discharge is ignited using high order modes to overcome limitations imposed by the fundamental power coupler, allowing in-situ cleaning for cavities in cryomodule. The plasma can be easily ignited and tuned in each of the cavity cells using low RF power. A method for plasma detection has been developed as well, which allows the detection of the plasma location in the cavity without the need of cameras at both cavity ends. The presented method can be applied to other multi-cell cavity designs, even for accelerators where the coupling for the fundamental modes at room temperature is very weak.

physics.acc-ph↗

Achievement of Ultra-High Quality Factor in Prototype Cryomodule for LCLS-II

Quality factor is a primary cost driver for high energy, continuous wave (CW) SRF linacs like the LCLS-II X-ray free electron laser currently under construction. Taking this into account, several innovations were introduced in the LCLS-II cryomodule design to push substantially beyond the previous state-of-the-art quality factor achieved in operation. This includes the first ever implementation of the nitrogen doping cavity treatment, the capability to provide high mass flow cooldown to improve expulsion of magnetic flux based on recent R&D, high performance magnetic shielding, and other critical subcomponents. To evaluate the implementation of these new cryomodule features, two prototype cryomodules were produced. In this paper, we present results from the prototype cryomodule assembled at Fermilab, which achieved unprecedented cavity quality factors of 3.0e10 at a nominal cryomodule voltage. We overview cavity performance, procedures to achieve ambient magnetic field < 5 mG at the cavity wall, and the successful demonstration of high mass flow cooldown in a cryomodule. The cavity performance under various cool down conditions are presented as well to show the impact of flux expulsion on Q0.

physics.acc-ph↗

The Role of Magnetic Flux Expulsion to Reach Q0>3x10^10 in SRF Cryomodules

When a superconducting radiofrequency cavity is cooled through its critical temperature, ambient magnetic flux can become "frozen in" to the superconductor, resulting in degradation of the quality factor. This is especially problematic in applications where quality factor is a cost driver, such as in the CW linac for LCLS-II. Previously, it had been unknown how to prevent flux from being trapped during cooldown in bulk niobium cavities, but recent R&D studies showed near-full flux expulsion can be achieved through high temperature heat treatment and cooling cavities through the superconducting transition with a spatial thermal gradient over the surface. In this paper, we describe the first accelerator implementation of these procedures, in cryomodules that are currently being produced for LCLS-II. We compare the performance of cavities under different conditions of heat treatment and thermal gradient during cooldown, showing a substantial improvement in performance when both are applied, enabling cryomodules to reach and, in many cases, exceed a Q0 of ~3x10^10.

physics.acc-ph↗

Accelerating fields up to 49 MV/m in TESLA-shape superconducting RF niobium cavities via 75C vacuum bake

In this paper we present the discovery of a new surface treatment applied to superconducting radio frequency (SRF) niobium cavities, leading to unprecedented accelerating fields of 49 MV/m in TESLA-shaped cavities, in continuous wave (CW); the corresponding peak magnetic fields are the highest ever measured in CW, about 210 mT. For TESLA-shape cavities the maximum quench field ever achieved was ~45 MV/m - reached very rarely- with most typical values being below 40 MV/m. These values are reached for niobium surfaces treated with electropolishing followed by the so called mild bake, a 120C vacuum bake (for 48 hours for fine grain and 24 hours for large grain surfaces). We discover that the addition during the mild bake of a step at 75C for few hours, before the 120C, increases systematically the quench fields up to unprecedented values of 49 MV/m. The significance of the result lays not only in the relative improvement, but in the proof that niobium surfaces can sustain and exceed CW radio frequency magnetic fields much larger than Hc1, pointing to an extrinsic nature of the current field limitations, and therefore to the potential to reach accelerating fields well beyond the current state of the art.

physics.acc-ph↗

Insight into bulk niobium superconducting RF cavities performances by tunneling spectroscopy

Point contact tunneling (PCT) spectroscopy measurements are reported over wide areas of cm-sized cut outs from niobium superconducting RF cavities. A comparison is made between a high-quality, conventionally processed (CP) cavity with a high field Q drop for acceleration field E $>$ 20 MV/m and a nitrogen doped (N-doped) cavity that exhibits an increasing Q up to fields approaching 15 MV/m. The CP cavity displays hot spot regions at high RF fields where Q-drop occurs as well as unaffected regions (cold spots). PCT data on cold spots reveals a near ideal BCS density of states (DOS) with gap parameters, $Δ$ as high as 1.62 meV, that are among the highest values ever reported for Nb. Hot spot regions exhibit a wide distribution of gap values down to $Δ\sim$ 1.0 meV and DOS broadening characterized by a relatively large value of pair-breaking rate, $Γ$, indicating surface regions of significantly reduced superconductivity. In addition, hot spots commonly exhibit Kondo tunneling peaks indicative of surface magnetic moments attributed to a defective oxide. N-doped cavities reveal a more homoegeneous gap distribution centered at $Δ\sim$ 1.5 meV and relatively small values of $Γ/Δ$. The absence of regions of significantly reduced superconductivity indicates that the N interstitials are playing an important role in preventing the formation of hydride phases and other macroscopic defects which might otherwise severely affect the local, surface superconductivity that lead to hot spot formation. The N-doped cavities also display a significantly improved surface oxide, i.e., increased thickness and tunnel barrier height, compared to CP cavities. These results help explain the improved performance of N-doped cavities and give insights into the origin of the initial increasing Q with RF amplitude.

cond-mat.supr-con↗

Commissioning And First Results From The Fermilab Cryomodule Test Stand

A new test stand dedicated to Superconducting Radiofrequency (SRF) cryomodule testing, CMTS1, has been commissioned and is now in operation at Fermilab. The first device to be cooled down and powered in this facility is the prototype 1.3 GHz cryomodule assembled at Fermilab for LCLS-II. We describe the demonstrated capabilities of CMTS1, report on steps taken during commissioning, provide an overview of first test results, and survey future plans.

physics.acc-ph↗

The Effect of Mechanical Cold Work on the Magnetic Flux Expulsion of Niobium

Expulsion of ambient flux has been shown to be crucial to obtain high quality factors in bulk niobium SRF cavities. However, there remain many questions as to what properties of the niobium material determine its flux expulsion behavior. In this paper, we present first results from a new study of two cavities that were specially fabricated to study flux expulsion. Both cavities were made from large grain ingot niobium slices, one of which had its slices rolled prior to fabrication, and none these slices were annealed prior to measurement. Expulsion measurements indicate that a dense network of grain boundaries is not necessary for a cavity to have near-complete flux trapping behavior up to large thermal gradients. The results also contribute to a body of evidence that cold work is a strong determinant of flux expulsion behavior in SRF-grade niobium.

physics.acc-ph↗

Advancement in the understanding of the field and frequency dependent microwave surface resistance of niobium

The radio-frequency surface resistance of niobium resonators is incredibly reduced when nitrogen impurities are dissolved as interstitial in the material, conferring ultra-high Q-factors at medium values of accelerating field. This effect has been observed in both high and low temperature nitrogen treatments. As a matter of fact, the peculiar anti Q-slope observed in nitrogen doped cavities, i.e. the decreasing of the Q-factor with the increasing of the radio-frequency field, come from the decreasing of the BCS surface resistance component as a function of the field. Such peculiar behavior has been considered consequence of the interstitial nitrogen present in the niobium lattice after the doping treatment. The study here presented show the field dependence of the BCS surface resistance of cavities with different resonant frequencies, such as: 650 MHz, 1.3 GHz, 2.6 GHz and 3.9 GHz, and processed with different state-of-the-art surface treatments. These findings show for the first time that the anti Q-slope might be seen at high frequency even for clean Niobium cavities, revealing useful suggestion on the physics underneath the anti Q-slope effect.

physics.acc-ph↗

Unprecedented Quality Factors at Accelerating Gradients up to 45 MV/m in Niobium Superconducting Resonators via Low Temperature Nitrogen Infusion

We report the finding of new surface treatments that permit to manipulate the niobium resonator nitrogen content in the first few nanometers in a controlled way, and the resonator fundamental Mattis-Bardeen surface resistance and residual resistance accordingly. In particular, we find surface infusion conditions that systematically a) increase the quality factor of these 1.3 GHz superconducting radio frequency (SRF) bulk niobium resonators, up to very high gradients; b) increase the achievable accelerating gradient of the cavity compared to its own baseline with state-of-the-art surface processing. Cavities subject to the new surface process have larger than two times the state of the art Q at 2K for accelerating fields > 35 MV/m. Moreover, very high accelerating gradients ~ 45 MV/m are repeatedly reached, which correspond to peak magnetic surface fields of 190 mT, among the highest measured for bulk niobium cavities. These findings open the opportunity to tailor the surface impurity content distribution to maximize performance in Q and gradients, and have therefore very important implications on future performance and cost of SRF based accelerators. They also help deepen the understanding of the physics of the RF niobium cavity surface.

physics.acc-ph↗

Effect of interstitial impurities on the field dependent microwave surface resistance of niobium

Previous work has demonstrated that the radio frequency surface resistance of niobium resonators is dramatically reduced when nitrogen impurities are dissolved as interstitial in the material. The origin of this effect is attributed to the lowering of the Mattis and Bardeen surface resistance contribution with increasing accelerating field. Meanwhile, an enhancement of the sensitivity to trapped magnetic field is typically observed for such cavities. In this paper we conduct the first systematic study on these different components contributing to the total surface resistance as a function of different levels of dissolved nitrogen, in comparison with standard surface treatments for niobium resonators. Adding these results together we are able to show for the first time which is the optimum surface treatment that maximizes the Q-factor of superconducting niobium resonators as a function of expected trapped magnetic field in the cavity walls. These results also provide new insights on the physics behind the change in the field dependence of the Mattis and Bardeen surface resistance, and of the trapped magnetic vortex induced losses in superconducting niobium resonators.

physics.acc-ph↗

Quench-Induced Degradation of the Quality Factor in Superconducting Resonators

Quench of superconducting radio-frequency cavities frequently leads to the lowered quality factor Q0, which had been attributed to the additional trapped magnetic flux. Here we demonstrate that the origin of this magnetic flux is purely extrinsic to the cavity by showing no extra dissipation (unchanged Q0) after quenching in zero magnetic field, which allows us to rule out intrinsic mechanisms of flux trapping such as generation of thermal currents or trapping of the rf field. We also show the clear relation of dissipation introduced by quenching to the orientation of the applied magnetic field and the possibility to fully recover the quality factor by requenching in the compensated field. We discover that for larger values of the ambient field, the Q-factor degradation may become irreversible by this technique, likely due to the outward flux migration beyond the normal zone opening during quench. Our findings are of special practical importance for accelerators based on low- and medium-beta accelerating structures residing close to focusing magnets, as well as for all high-Q cavity-based accelerators.

physics.acc-ph↗

Efficient expulsion of magnetic flux in superconducting RF cavities for high $Q_0$ applications

Even when cooled through its transition temperature in the presence of an external magnetic field, a superconductor can expel nearly all external magnetic flux. This Letter presents an experimental study to identify the parameters that most strongly influence flux trapping in high purity niobium during cooldown. This is critical to the operation of superconducting radiofrequency cavities, in which trapped flux degrades the quality factor and therefore cryogenic efficiency. Flux expulsion was measured on a large survey of 1.3 GHz cavities prepared in various ways. It is shown that both spatial thermal gradient and high temperature treatment are critical to expelling external magnetic fields, while surface treatment has minimal effect. For the first time, it is shown that a cavity can be converted from poor expulsion behavior to strong expulsion behavior after furnace treatment, resulting in a substantial improvement in quality factor. Future plans are described to build on this result in order to optimize treatment for future cavities.

physics.acc-ph↗