SearcharxivSearch

arXiv subjects

A. Halavanau

Publications and source records attributed to A. Halavanau.

14 recordsLinked to original sources

Confirming X-ray Parametric Down Conversion by Time-Energy Correlation

We present measurements of X-ray Parametric Down Conversion at the Advanced Photon Source synchrotron facility. Using an incoming pump beam at 22 keV, we observe the simultaneous, elastic emission of down-converted photon pairs generated in a diamond crystal. The pairs are detected using high count rate silicon drift detectors with low noise. Production by down-conversion is confirmed by measuring time-energy correlations in the detector signal, where photon pairs within an energy window ranging from 10 to 12 keV are only observed at short time differences. By systematically varying the crystal misalignment and detector positions, we obtain results that are consistent with the constant total of the down-converted signal. Our maximum rate of observed pairs was 130 /hour, corresponding to a conversion efficiency for the down-conversion process of $5.3 \pm 0.5 \times 10^{-13}$.

quant-ph

Single-shot Transverse Wakefield Mapping with a Hollow Electron Beam

Beam-driven wakefield accelerators are foreseen to enable compact accelerator-based light sources and play a critical role in future linear-collider concepts. This class of wakefield acceleration has been extensively studied over the last four decades with a focus on demonstrating its ability to support high-accelerating gradient and, most recently, enhanced transformer ratios. Yet, the associated detrimental transverse wakefields have not been examined in as many details due to the limited diagnostics available. In this paper, we introduce a beam-based single-shot transverse-wakefield measurement technique. The approach employs a witness ''hollow" electron beam to probe the wakefields generated by a drive bunch. We show how the transverse distortions of the hollow probe provide a direct measurement of the wakefield distribution within the area circumscribed by the probe. The ability to directly measure a full structure of the transverse wakefield could help to develop mitigation schemes and ultimately suppress the adverse beam-break-up instabilities. We discuss a practical implementation of the method and demonstrate its performance with the help of start-to-end simulations.

physics.acc-ph

An Ultra-Compact X-Ray Free-Electron Laser

In the field of beam physics, two frontier topics have taken center stage due to their potential to enable new approaches to discovery in a wide swath of science. These areas are: advanced, high gradient acceleration techniques, and x-ray free electron lasers (XFELs). Further, there is intense interest in the marriage of these two fields, with the goal of producing a very compact XFEL. In this context, recent advances in high gradient radio-frequency cryogenic copper structure research have opened the door to the use of surface electric fields between 250 and 500 MV/m. Such an approach is foreseen to enable a new generation of photoinjectors with six-dimensional beam brightness beyond the current state-of-the-art by well over an order of magnitude. This advance is an essential ingredient enabling an ultra-compact XFEL (UC-XFEL). In addition, one may accelerate these bright beams to GeV scale in less than 10 meters. Such an injector, when combined with inverse free electron laser-based bunching techniques can produce multi-kA beams with unprecedented beam quality, quantified by ~50 nm-rad normalized emittances. These beams, when injected into innovative, short-period (1-10 mm) undulators uniquely enable UC-XFELs having footprints consistent with university-scale laboratories. We describe the architecture and predicted performance of this novel light source, which promises photon production per pulse of a few percent of existing XFEL sources. We review implementation issues including collective beam effects, compact x-ray optics systems, and other relevant technical challenges. To illustrate the potential of such a light source to fundamentally change the current paradigm of XFELs with their limited access, we examine possible applications in biology, chemistry, materials, atomic physics, industry, and medicine which may profit from this new model of performing XFEL science.

physics.acc-ph

Design and Characteristics of a Population Inversion X-ray Laser Oscillator

Oscillators are at the heart of optical lasers, providing stable transform limited pulses. In contrast, X-ray free electron lasers use self-amplified spontaneous emission (SASE), resulting in large stochastic intensity and spectral fluctuations. Amplified spontaneous emission (ASE) of the $K\alpha_1$ line has been recently observed for Ne gas, Cu compounds and Mn solutions at the LCLS and SACLA X-ray free electron lasers (XFELs), using an X-ray SASE pulse as a pump to create population inversion. Here we describe the physics and realization of an X-ray laser oscillator (XLO) based on periodically pumping a Cu compound gain medium in a tunable Bragg cavity with a SASE pulse train, generating intense ($\sim$ 5 x 10$^{10}$ ph/pulse), fully coherent, transform limited 8 keV pulses with 48 meV spectral resolution. We also discuss extending these results to other elements to operate XLO from about 5 to 12 keV, improving X-ray-based research beyond current capabilities.

physics.acc-ph

Tailoring of an Electron-Bunch Current Distribution via Space-to-Time Mapping of a Transversely-Shaped Photoemission-Laser Pulse

Temporally-shaped electron bunches at ultrafast time scales are foreseen to support an array of applications including the development of small-footprint accelerator-based coherent light sources or as probes for, e.g., ultrafast electron-diffraction. We demonstrate a method where a transversely-segmented electron bunch produced via photoemission from a transversely-patterned laser distribution is transformed into an electron bunch with modulated temporal distribution. In essence, the presented transformation enables the mapping of the transverse laser distribution on a photocathode surface to the temporal coordinate and provides a proof-of-principle experiment of the method proposed in W. S. Graves, et al. as a path toward the realization of compact coherent X-ray sources, albeit at a larger timescale. The presented experiment is validated against numerical simulations and the versatility of the concept, e.g. to tune the current-distribution parameters, is showcased. Although our work focuses on the generation of electron bunches arranged as a temporal comb it is applicable to other temporal shapes.

physics.acc-ph

Linear Lattice and Trajectory Reconstruction and Correction at FAST Linear Accelerator

The low energy part of the FAST linear accelerator based on 1.3 GHz superconducting RF cavities was successfully commissioned. During commissioning, beam based model dependent methods were used to correct linear lattice and trajectory. Lattice correction algorithm is based on analysis of beam shape from profile monitors and trajectory responses to dipole correctors. Trajectory responses to field gradient variations in quadrupoles and phase variations in superconducting RF cavities were used to correct bunch offsets in quadrupoles and accelerating cavities relative to their magnetic axes. Details of used methods and experimental results are presented.

physics.acc-ph

Spatial Control of Photoemitted Electron Beams using a Micro-Lens-Array Transverse-Shaping Technique

A common issue encountered in photoemission electron sources used in electron accelerators is the transverse inhomogeneity of the laser distribution resulting from the laser-amplification process and often use of frequency up conversion in nonlinear crystals. A inhomogeneous laser distribution on the photocathode produces charged beams with lower beam quality. In this paper, we explore the possible use of microlens arrays (fly-eye light condensers) to dramatically improve the transverse uniformity of the drive laser pulse on UV photocathodes. We also demonstrate the use of such microlens arrays to generate transversely-modulated electron beams and present a possible application to diagnose the properties of a magnetized beam.

physics.acc-ph

Analysis and Measurement of the Transfer Matrix of a 9-cell 1.3-GHz Superconducting Cavity

Superconducting linacs are capable of producing intense, stable, high-quality electron beams that have found widespread applications in science and industry. The 9-cell 1.3-GHz superconducting standing-wave accelerating RF cavity originally developed for $e^+/e^-$ linear-collider applications [B. Aunes, {\em et al.} Phys. Rev. ST Accel. Beams {\bf 3}, 092001 (2000)] has been broadly employed in various superconducting-linac designs. In this paper we discuss the transfer matrix of such a cavity and present its measurement performed at the Fermilab Accelerator Science and Technology (FAST) facility. The experimental results are found to be in agreement with analytical calculations and numerical simulations.

physics.acc-ph

Commissioning and First Results From Channeling Radiation At FAST

X-rays have widespread applications in science and industry, but developing a simple, compact, and high-quality X-ray source remains a challenge. Our collaboration has explored the possible use of channeling radiation driven by a 50 MeV low-emittance electron beam to produce narrowband hard X-rays with photon energy of 40 to 140 keV. Here we present the simulated X-ray spectra including the background bremsstrahlung contribution, and a description of the required optimization of the relevant electron-beam parameters necessary to maximize brilliance of the resulting X-ray beam. Results are presented from our test of this, carried out at the Fermilab Accelerator Science & Technology (FAST) facility's 50-MeV low-energy electron injector. As a result of the beam parameters, made possible by the photo-injector based SRF linac, the average brilliance at FAST was expected to be about one order of magnitude higher than that in previous experiments.

physics.acc-ph

Microlens Array Laser Transverse Shaping Technique for Photoemission Electron Source

A common issue encountered in photoemission electron sources used in electron accelerators is distortion of the laser spot due to non ideal conditions at all stages of the amplification. Such a laser spot at the cathode may produce asymmetric charged beams that will result in degradation of the beam quality due to space charge at early stages of acceleration and fail to optimally utilize the cathode surface. In this note we study the possibility of using microlens arrays to dramatically improve the transverse uniformity of the drive laser pulse on UV photocathodes at both Fermilab Accelerator Science \& Technology (FAST) facility and Argonne Wakefield Accelerator (AWA). In particular, we discuss the experimental characterization of the homogeneity and periodic patterned formation at the photocathode. Finally, we compare the experimental results with the paraxial analysis, ray tracing and wavefront propagation software.

physics.acc-ph

Simulation of a cascaded longitudinal space charge amplifier for broadband radiation production using a superconducting linac

Longitudinal space charge (LSC) effects are generally considered harmful in free-electron lasers as they can seed unfavorable energy modulations that can result in density modulations with associated emittance dilution. It was pointed out, however, that such "micro-bunching instabilities" could be potentially useful to support the generation of broadband coherent radiation. Therefore there has been an increasing interest in devising accelerator beam lines capable of controlling LSC induced density modulations. In the present paper we augment these previous investigations by combining a grid-less space charge algorithm with the popular particle-tracking program Elegant. This high-fidelity model of the space charge is used to benchmark conventional LSC models. We finally employ the developed model to optimize the performance of a cascaded longitudinal space charge amplifier using beam parameters comparable to the ones achievable at Fermilab Accelerator Science & Technology (FAST) facility currently under commissioning at Fermilab.

physics.acc-ph

Isorotating Baby Skyrmions

We discuss how internal rotation with fixed angular frequency can affect the solitons in the baby Skyrme model in which the global O(3) symmetry is broken to the SO(2). Two particular choices of the potential term are considered, the "old" potential and the "new" double vacuum potential, We do not impose any assumptions about the symmetry on the fields. Our results confirm existence of two types of instabilities determined by the relation between the mass parameter of the potential and the angular frequency.

hep-th

Resonance structures in coupled two-component $ϕ^4$ model

We present a numerical study of the process of the kink-antikink collisions in the coupled one-dimensional two-component $ϕ^4$ model. Our results reveal two different soliton solutions which represent double kink configuration and kink-non-topological soliton (lump) bound state. Collision of these solitons leads to very reach resonance structure which is related to reversible energy exchange between the kinks, non-topological solitons and the internal vibrational modes. Various channels of the collisions are discussed, it is shown there is a new type of self-similar fractal structure which appears in the collisions of the relativistic kinks, there the width of the resonance windows increases with the increase of the impact velocity. An analytical approximation scheme is discussed in the limit of the perturbative coupling between the sectors. Considering the spectrum of linear fluctuations around the solitons we found that the double kink configuration is unstable if the coupling constant between the sectors is negative.

hep-th

Hopfion canonical quantization

We study the effect of the canonical quantization of the rotational mode of the charge Q=1 and Q=2 spinning Hopfions. The axially-symmetric solutions are constructed numerically, it is shown the quantum corrections to the mass of the configurations are relatively large.

hep-th