SearcharxivSearch

arXiv subjects

A. J. Biffl

Publications and source records attributed to A. J. Biffl.

7 recordsLinked to original sources

Calibration and Performance of Germanium High Voltage Detectors for SuperCDMS SNOLAB

As SuperCDMS SNOLAB is getting ready to search for low mass dark matter particles, using cryogenic Ge and Si detectors, a set of six of the new SuperCDMS High Voltage (HV) detectors (four Ge and two Si) were tested in the Cryogenic Underground TEst facility (CUTE) at SNOLAB. This provided the first opportunity to gain experience with this new detector type and assess their performance thoroughly under low background conditions. Here we describe the SuperCDMS HV detector concept and discuss some of the newly developed analysis methods and approaches. Focusing on the Ge detectors, we investigate the detector performance under voltage bias (up to 90 V), exercise the low energy (keV to sub-keV range) calibration based on the electron capture peaks generated by the decay of $^{71}$Ge, assess the detector resolution, and demonstrate the unexpected (and encouraging) ability of these detectors to also measure high energy interactions in the hundreds of keV range with good resolution (better than 3% at 356 keV).

physics.ins-det

Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV Detector

We present constraints on low-mass dark matter electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of $6.1\,\mathrm{g\cdot days}$ of exposure produces exclusion limits for dark matter-electron scattering cross sections for masses as low as $1\,\mathrm{MeV}/c^2$, as well as on the photon-dark photon mixing parameter and the coupling constant between axionlike particles and electrons for particles with masses $>1.2\,\mathrm{eV}/c^2$ probed via absorption processes.

hep-ex

Low-Energy Calibration of SuperCDMS HVeV Cryogenic Silicon Calorimeters Using Compton Steps

Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. We demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution (HVeV) detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.

physics.ins-det

Applying Geant4's Importance Biasing to improve the efficiency of SuperCDMS background simulations

Experiments searching for extremely rare events surround their sensitive detectors with several layers of different shielding materials to protect them from external radiation and to achieve their low-background requirements to be able to observe a potential signal. Standard Monte Carlo simulations that propagate particles through the thick shielding, usually do not penetrate the shield in sufficient numbers to properly model the external background, which is crucial for understanding the experiment's background composition. Geant4 is a widely used toolkit to simulate the passage of particles through matter and it offers various biasing techniques, among them being importance biasing, which has been intensively explored for application in background simulations for the SuperCDMS experiment. In this article, the basic working principle of importance biasing is explained. Furthermore, we provide guidance for developers for their own implementation of a biasing scheme. A new track property, the "biasing index", is introduced to allow different track topologies to be distinguished. Validation studies and optimal parameters for biasing gammas and neutrons are presented and caveats are discussed. In this work, simulations run with importance biasing achieved an efficiency boost of about $\mathcal{O}(10^4)$ for gammas and up to 500 for neutrons. By applying these techniques, we show that energy distributions simulated with and without importance biasing are consistent with each other within statistical uncertainty at a fraction of the consumed computing time.

hep-ex

Light Dark Matter Constraints from SuperCDMS HVeV Detectors Operated Underground with an Anticoincidence Event Selection

This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon kinetic mixing and axion-like particle axioelectric coupling for masses between 1.2 and 23.3 eV/$c^2$. Compared to an earlier HVeV search, sensitivity was improved as a result of an increased overburden of 225 meters of water equivalent, an anticoincidence event selection, and better pile-up rejection. In the case of dark-matter-electron scattering via a heavy mediator, an improvement by up to a factor of 25 in cross-section sensitivity was achieved.

hep-ex

Neutron capture-induced nuclear recoils as background for CE$ν$NS~measurements at reactors

Nuclear reactors represent a promising neutrino source for CE$ν$NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can create a spectrum that strongly overlaps the CE$ν$NS signal for recoils $\lesssim$\,100\,eV for nuclear reactor measurements in silicon or germanium detectors. This background can be particularly critical for low-power research reactors providing a moderate neutrino flux. In this work we quantify the impact of this background and show that, for a measurement 10\,m from a 1\,MW reactor, the effective thermal neutron flux should be kept below $\sim$~7$\times$~10$^{-4}$\,n/cm$^2$s so that the CE$ν$NS events can be measured at least at a 5$σ$ level with germanium detectors in 100~kg\,yr exposure time. This flux corresponds to 60\% of the sea-level flux but needs to be achieved in a nominally high-flux (reactor) environment. Improved detector resolution can help the measurements, but the thermal flux is the key parameter for the sensitivity of the experiment. For silicon detectors, the constraint is even stronger and thermal neutron fluxes must be near an order of magnitude lower. This constraint highlights the need of an effective thermal neutron mitigation strategy for future low threshold CE$ν$NS searches. In particular, the neutron capture-induced background can be efficiently reduced by active veto systems tagging the deexcitation gamma following the capture.

hep-ex

Neutron capture-induced silicon nuclear recoils for dark matter and CE$ν$NS

Following neutron capture in a material there will be prompt nuclear recoils in addition to the gamma cascade. The nuclear recoils that are left behind in materials are generally below 1\,keV and therefore in the range of interest for dark matter experiments and CE$ν$NS studies--both as backgrounds and calibration opportunities. Here we obtain the spectrum of prompt nuclear recoils following neutron capture for silicon.

hep-ex