SearcharxivSearch

arXiv subjects

A. J. Blue

Publications and source records attributed to A. J. Blue.

2 recordsLinked to original sources

Cracking under pressure --- investigating mitigation approaches for silicon fractures on ATLAS strip tracker petals at cold temperatures

For the High-Luminosity upgrade of the Large Hadron Collider, the ATLAS experiment will replace its current Inner Detector with an all-silicon Inner Tracker (ITk), consisting of pixel and strip detectors. The strip detector will consist of a central region or "barrel" assembled with staves and forward regions or "end-caps" assembled with petals. The ITk will nominally operate with liquid $\textrm{CO}^2$ cooling at $-35\,^\circ\textrm{C}$; however, in the event of cooling system failures, it is possible that sensors will experience temperatures below $-35\,^\circ\textrm{C}$. At these low temperatures, it has been observed that the silicon sensors within modules --- the fundamental readout units of the detector --- can physically crack, rendering the modules inoperable. Understanding and resolving the issue of sensor cracking was one of the most important and urgent issues for the ITk project. This paper presents part of the mitigation strategies developed for petals. These mitigation strategies are based on modifications to the choice of adhesive and its deposition pattern for module assembly and petal loading. The most promising mitigation strategy presented here prevents cracking to temperatures as low as $-45\,^\circ\textrm{C}$, which can be expected in case of cooling system problems, with a small percentage of cracks observed after being cycled to $-55\,^\circ\textrm{C}$, which can be expected in case of catastrophic cooling system failures.

physics.ins-det

Mapping the in-plane electric field inside irradiated diodes

A significant aspect of the Phase-II Upgrade of the ATLAS detector is the replacement of the current Inner Detector with the ATLAS Inner Tracker (ITk). The ATLAS ITk is an all-silicon detector consisting of a pixel tracker and a strip tracker. Sensors for the ITk strip tracker have been developed to withstand the high radiation environment in the ATLAS detector after the High Luminosity Upgrade of the Large Hadron Collider at CERN, which will significantly increase the rate of particle collisions and resulting particle tracks. During their operation in the ATLAS detector, sensors for the ITk strip tracker are expected to accumulate fluences up to 1.6 x 10^15 n_eq/cm^2 (including a safety factor of 1.5), which will significantly affect their performance. One characteristic of interest for highly irradiated sensors is the shape and homogeneity of the electric field inside its active area. For the results presented here, diodes with edge structures similar to full size ATLAS sensors were irradiated up to fluences comparable to those in the ATLAS ITk strip tracker and their electric fields mapped using a micro-focused X-ray beam (beam diameter 2x3 μm^2). This study shows the extension and shape of the electric field inside highly irradiated diodes over a range of applied bias voltages. Additionally, measurements of the outline of the depleted sensor areas allow a comparison of the measured leakage current for different fluences with expectations for the corresponding active areas.

physics.ins-det