SearcharxivSearch

arXiv subjects

A. J. Miller

Publications and source records attributed to A. J. Miller.

9 recordsLinked to original sources

Charge radii of $^{55,56}$Ni reveal a surprisingly similar behavior at $N=28$ in Ca and Ni isotopes

Nuclear charge radii of $^{55,56}$Ni were measured by collinear laser spectroscopy. The obtained information completes the behavior of the charge radii at the shell closure of the doubly magic nucleus $^{56}$Ni. The trend of charge radii across the shell closures in calcium and nickel is surprisingly similar despite the fact that the $^{56}$Ni core is supposed to be much softer than the $^{48}$Ca core. The very low magnetic moment $μ(^{55}\mathrm{Ni})=-1.108(20)\,μ_N$ indicates the impact of M1 excitations between spin-orbit partners across the $N,Z=28$ shell gaps. Our charge-radii results are compared to \textit{ab initio} and nuclear density functional theory calculations, showing good agreement within theoretical uncertainties.

nucl-ex

Ground State Electromagnetic Moments of $^{37}$Ca

The hyperfine coupling constants of neutron deficient $^{37}$Ca were deduced from the atomic hyperfine spectrum of the $4s~^2S_{1/2}$ $\leftrightarrow$ $4p~^2P_{3/2}$ transition in Ca II, measured using the collinear laser spectroscopy technique. The ground-state magnetic-dipole and spectroscopic electric-quadrupole moments were determined for the first time as $μ= +0.7453(72) μ_N$ and $Q = -15(11)$ $e^2$fm$^2$, respectively. The experimental values agree well with nuclear shell model calculations using the universal sd model-space Hamiltonians versions A and B (USDA/B) in the $sd$-model space with a 95\% probability of the canonical nucleon configuration. It is shown that the magnetic moment of $^{39}$Ca requires a larger non-$sd$-shell component than that of $^{37}$Ca for good agreement with the shell-model calculation, indicating a more robust closed sub-shell structure of $^{36}$Ca at the neutron number $N$ = 16 than $^{40}$Ca. The results are also compared to valence-space in-medium similarity renormalization group calculations based on chiral two- and three-nucleon interactions.

nucl-ex

The SeaQuest Spectrometer at Fermilab

The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell-Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets and four detector stations. The upstream magnet is a closed-aperture solid iron magnet which also serves as the beam dump, while the second magnet is an open aperture magnet. Each of the detector stations consists of scintillator hodoscopes and a high-resolution tracking device. The FPGA-based trigger compares the hodoscope signals to a set of pre-programmed roads to determine if the event contains oppositely-signed, high-mass muon pairs.

physics.ins-det

Phase-tuned entangled state generation between distant spin qubits

Quantum entanglement between distant qubits is an important feature of quantum networks. Distribution of entanglement over long distances can be enabled through coherently interfacing qubit pairs via photonic channels. Here, we report the realization of optically generated quantum entanglement between electron spin qubits confined in two distant semiconductor quantum dots. The protocol relies on spin-photon entanglement in the trionic $Λ$-system and quantum erasure of the Raman-photon path. The measurement of a single Raman photon is used to project the spin qubits into a joint quantum state with an interferometrically stabilized and tunable relative phase. We report an average Bell-state fidelity for $|ψ^{(+)}\rangle$ and $|ψ^{(-)}\rangle$ states of $61.6\pm2.3\%$ and a record-high entanglement generation rate of 7.3 kHz between distant qubits.

quant-ph

Influence of Ti doping on the incommensurate charge density wave in 1T-TaS2

We report temperature-dependent transport and x-ray diffraction measurements of the influence of Ti hole doping on the charge density wave (CDW) in 1T-Ta(1-x)Ti(x)S(2). Confirming past studies, we find that even trace impurities eliminate the low-temperature commensurate (C) phase in this system. Surprisingly, the magnitude of the in-plane component of the CDW wave vector in the nearly commensurate (NC) phase does not change significantly with Ti concentration, as might be expected from a changing Fermi surface volume. Instead, the angle of the CDW in the basal plane rotates, from 11.9 deg at x=0 to 16.4 deg at x=0.12. Ti substitution also leads to an extended region of coexistence between incommensurate (IC) and NC phases, indicating heterogeneous nucleation near the transition. Finally, we explain a resistive anomaly originally observed by DiSalvo [F. J. DiSalvo, et al., Phys. Rev. B {\bf 12}, 2220 (1975)] as arising from pinning of the CDW on the crystal lattice. Our study highlights the importance of commensuration effects in the NC phase, particularly at x ~ 0.08.

cond-mat.str-el

Long-distance quantum key distribution in optical fiber

Use of low-noise detectors can both increase the secret bit rate of long-distance quantum key distribution (QKD) and dramatically extend the length of a fibre optic link over which secure key can be distributed. Previous work has demonstrated use of ultra-low-noise transition-edge sensors (TESs) in a QKD system with transmission over 50 km. In this work, we demonstrate the potential of the TESs by successfully generating error-corrected, privacy-amplified key over 148.7 km of dark optical fibre at a mean photon number mu = 0.1, or 184.6 km of dark optical fibre at a mean photon number of 0.5. We have also exchanged secret key over 67.5 km that is secure against powerful photon-number-splitting attacks.

quant-ph

UV-IR Science Prospects with TES Imaging Arrays

We are developing photon-counting cameras employing cryogenic arrays of energy-resolving TES (Transition Edge Sensor) pixels. These are being tested in ground-based instruments, but will have their greatest impact when employed on space platforms, where they can cover the 10micrometer-100nm range with high time- and moderate energy- resolution. Here we summarize briefly existing device performance, current directions in array camera development and anticipated capabilities.

astro-ph

Phase-resolved Crab Studies with a Cryogenic TES Spectrophotometer

We are developing time- and energy-resolved near-IR/optical/UV photon detectors based on sharp superconducting-normal transition edges in thin films. We report observations of the Crab pulsar made during prototype testing at the McDonald 2.7m telescope with a fiber-coupled transition-edge sensor (TES) system. These data show substantial (d[alpha]~0.3), rapid variations in the spectral index through the pulse profile, with a strong phase-varying IR break across our energy band. These variations correlate with X-ray spectral variations, but no single synchrotron population can account for the full Spectral Energy Distribution (SED). We also describe test spectrophotopolarimetry observations probing the energy dependence of the polarization sweep; this may provide a new key to understanding the radiating particle population.

astro-ph

First Astronomical Application of a Cryogenic TES Spectrophotometer

We report on the first astronomical observations with a photon counting pixel detector that provides arrival time- (delta t = 100ns) and energy- (delta E_gamma < 0.15eV) resolved measurements from the near IR through the near UV. Our test observations were performed by coupling this Transition Edge Sensor (TES) device to a 0.6m telescope; we have obtained the first simultaneous optical near-IR phase-resolved spectra of the Crab pulsar. A varying infrared turnover gives evidence of self-absorption in the pulsar plasma. The potential of such detectors in imaging arrays from a space platform are briefly described.

astro-ph