SearcharxivSearch

arXiv subjects

A. Jastram

Publications and source records attributed to A. Jastram.

At least 19 recordsLinked to original sources

Exploring Low Energy Excess in MINER with sapphire detectors using Convolutional Variational Autoencoder (CVAE)

As cryogenic detectors push toward ever-lower energy thresholds, their sensitivity is increasingly constrained by a persistent low-energy background known as the low-energy excess (LEE). We report observation of LEE in the MINER experiment using a sapphire ($\mathrm{Al_2O_3}$) detector at energies around 200 eV, with the excess reproducibly reappearing after each non-operational warm-up period. To address this limiting background, we implement an unsupervised convolutional variational autoencoder (CVAE) framework that identifies anomalous events through a reconstruction-based anomaly score. For the first time in a pulse-shape driven analysis, we uncover a significant deviation in the rise-time of LEE events relative to Monte Carlo simulated ideal signals. Using this feature, we develop a discrimination pipeline based on rise-time selection. This method achieves up to 53\% rejection of LEE events, corresponding to an expected sensitivity improvement of nearly 10\% for MINER at HFIR. These findings are consistent with a scenario in which a substantial fraction of the LEE originates from bulk-related defects or microfractures within the detector crystal, while leaving room for additional detector-related contributions. Our result provides a powerful, data-driven pathway for mitigating LEE and enhancing the discovery potential of next-generation cryogenic experiments.

physics.ins-det

CE$\nu$NS Search with Cryogenic Sapphire Detectors at MINER: Results from the TRIGA reactor data and Future Sensitivity at HFIR

We report on a search for coherent elastic neutrino--nucleus scattering (CE$\nu$NS) using cryogenic sapphire (Al$_2$O$_3$) detectors deployed at the Mitchell Institute Neutrino Experiment at Reactor (MINER), located near the 1~MW$_\text{th}$ TRIGA research reactor at Texas A\&M University. The experiment operated with a primary detector mass of 72~g and achieved a baseline energy resolution of $\sim 40$~eV. Using exposures of 158~g-days (reactor-on) and 381~g-days (reactor-off), we performed a statistical background subtraction in the energy region of 0.25--3~keV. A GEANT4 simulation has been performed to understand the reactor-correlated background present in the data and it agrees with our observations. The resulting best-fit ratio of the observed CE$\nu$NS rate to the Standard Model prediction after rejecting the reactor induced background from the data with the help of simulation, is $\rho = 0.26\pm 1534.74~\mathrm{(stat)} \pm 0.05~\mathrm{(sys)}$ with a significance of $0.007 \pm 0.022~\mathrm{(stat)} \pm 0.001~\mathrm{(sys)}$. This low significance indicates a high background rate at low energies. To have enhanced sensitivity, the MINER collaboration plans to relocate the experiment to the 85~MW$_\text{th}$ High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). With improved shielding, increased detector mass, and higher antineutrino flux, the upgraded setup is projected to achieve a 3$\sigma$ CE$\nu$NS detection within 30~kg$\cdot$days of exposure.

nucl-ex

MINER Reactor Based Search for Axion-Like Particles Using Sapphire (Al2O3) Detectors

The absence of definitive results for WIMP dark matter has sparked growing interest in alternative dark matter candidates, such as axions and Axion-Like Particles (ALPs), which also provide insight into the strong CP problem. The Mitchell Institute Neutrino Experiment at Reactor (MINER), conducted at the Nuclear Science Center of Texas A&M University, investigated ALPs near a 1 MW TRIGA nuclear reactor core, positioned approximately 4 meters away. This experiment employed cryogenic sapphire detectors with a low detection threshold (approximately 100 eV), equipped with a Transition Edge Sensor capable of detecting athermal phonons. Due to the low-background environment, we were able to exclude ALPs with axion-photon coupling and axion-electron coupling as small as \(g_{a\gamma\gamma} = 10^{-5}\) and \(g_{aee} = 10^{-7}\), respectively. Energy depositions below 3 keV were not considered and remain blinded for our Coherent Elastic Neutrino Nucleus Scattering (CEvNS) analysis. This is the first result demonstrating the MINER experiment's potential to probe low-mass ALPs, enabled by its low-threshold detector and proximity to a reactor.

hep-ex

A Strategy for Low-Mass Dark Matter Searches with Cryogenic Detectors in the SuperCDMS SNOLAB Facility

The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-based scenarios are forecasted to probe many square decades of unexplored dark matter parameter space below 5 GeV/c$^2$, covering over 6 decades in mass: 1-100 eV/c$^2$ for dark photons and axion-like particles, 1-100 MeV/c$^2$ for dark-photon-coupled light dark matter, and 0.05-5 GeV/c$^2$ for nucleon-coupled dark matter. They will reach the neutrino fog in the 0.5-5 GeV/c$^2$ mass range and test a variety of benchmark models and sharp targets. The novel directions involve greater departures from current SuperCDMS technology but promise even greater reach in the long run, and their development must begin now for them to be available in a timely fashion. The experienced-based upgrade scenarios rely mainly on dramatic improvements in detector performance based on demonstrated scaling laws and reasonable extrapolations of current performance. Importantly, these improvements in detector performance obviate significant reductions in background levels beyond current expectations for the SuperCDMS SNOLAB experiment. Given that the dominant limiting backgrounds for SuperCDMS SNOLAB are cosmogenically created radioisotopes in the detectors, likely amenable only to isotopic purification and an underground detector life-cycle from before crystal growth to detector testing, the potential cost and time savings are enormous and the necessary improvements much easier to prototype.

physics.ins-det

Investigating the sources of low-energy events in a SuperCDMS-HVeV detector

Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS-HVeV detector at three voltages across the crystal (0 V, 60 V and 100 V). The 0 V data show an excess of events in the tens of eV region. Despite this event excess, we demonstrate the ability to set a competitive exclusion limit on the spin-independent dark matter--nucleon elastic scattering cross section for dark matter masses of $\mathcal{O}(100)$ MeV/$c^2$, enabled by operation of the detector at 0 V potential and achievement of a very low $\mathcal{O}(10)$ eV threshold for nuclear recoils. Comparing the data acquired at 0 V, 60 V and 100 V potentials across the crystal, we investigated possible sources of the unexpected events observed at low energy. The data indicate that the dominant contribution to the excess is consistent with a hypothesized luminescence from the printed circuit boards used in the detector holder.

hep-ex

Ionization yield measurement in a germanium CDMSlite detector using photo-neutron sources

Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for nuclear recoil energies between 1 keV and 7 keV at a temperature of $\sim$ 50 mK. We use a Geant4 simulation to model the neutron spectrum assuming a charge yield model that is a generalization of the standard Lindhard model and consists of two energy dependent parameters. We perform a likelihood analysis using the simulated neutron spectrum, modeled background, and experimental data to obtain the best fit values of the yield model. The ionization yield between recoil energies of 1 keV and 7 keV is shown to be significantly lower than predicted by the standard Lindhard model for germanium. There is a general lack of agreement among different experiments using a variety of techniques studying the low-energy range of the nuclear recoil yield, which is most critical for interpretation of direct dark matter searches. This suggests complexity in the physical process that many direct detection experiments use to model their primary signal detection mechanism and highlights the need for further studies to clarify underlying systematic effects that have not been well understood up to this point.

physics.ins-det

Effective Field Theory Analysis of CDMSlite Run 2 Data

CDMSlite Run 2 was a search for weakly interacting massive particles (WIMPs) with a cryogenic 600 g Ge detector operated in a high-voltage mode to optimize sensitivity to WIMPs of relatively low mass from 2 - 20 GeV/$c^2$. In this article, we present an effective field theory (EFT) analysis of the CDMSlite Run 2 data using an extended energy range and a comprehensive treatment of the expected background. A binned likelihood Bayesian analysis was performed on the recoil energy data, taking into account the parameters of the EFT interactions and optimizing the data selection with respect to the dominant background components. Energy regions within 5$σ$ of known activation peaks were removed from the analysis. The Bayesian evidences resulting from the different operator hypotheses show that the CDMSlite Run 2 data are consistent with the background-only models and do not allow for a signal interpretation assuming any additional EFT interaction. Consequently, upper limits on the WIMP mass and coupling-coefficient amplitudes and phases are presented for each EFT operator. These limits improve previous CDMSlite Run 2 bounds for WIMP masses above 5 GeV/$c^2$.

astro-ph.CO

Large-mass, low-threshold sapphire detector for rare event searches

Low mass nuclear recoil dark matter and coherent-elastic-neutrino-nucleus-scattering (CENNS) searches confront similar challenges in choosing ultra-low threshold and large-mass detectors. We report experimental results from the first-of-its-kind 100 g single-crystal sapphire detector design with a diameter of 76 mm and thickness of 4 mm. The detector is designed to be sensitive for low-energy rare interactions with an intention to investigate the low mass region of dark matter phase-space and search for CENNS at the reactor site. Sapphire is a crystal of aluminum oxide (Al2O3) and has been found to be a good candidate for light mass spin-dependent dark matter search experiments due to its lower atomic mass compared to other detector materials such as germanium and silicon. Using the data collected from the test facility at Texas A&M University, we were able to resolve low energy lines from calibration sources and estimated that our newly developed sapphire detector has a baseline recoil energy resolution of 18 eV. These detectors are operated at 0 V with the phonon-assisted detection providing a quenching-free low-threshold operation.

physics.ins-det

A novel active veto prototype detector with an inner target for improved rare event searches

We report the fabrication and performance of an annular, cryogenic, phonon-mediated veto detector that can host an inner target detector, allowing substantial reduction in radiogenic backgrounds for rare event search experiments. A germanium veto detector of mass $\sim$500 g with an outer diameter of 76 mm and an inner diameter of 28 mm was produced. A 25 mm diameter germanium inner target detector of mass $\sim$10 g was mounted inside the veto detector. The detector was designed using inputs from a GEANT4 based simulation, where it was modeled to be sandwiched between two germanium detectors. The simulation showed that the background rates (dominantly gamma interactions) could be reduced by $>$ 90$\%$, and that such an arrangement is sufficient for aggressive background reduction needed for neutrino and dark matter search experiments. During testing at the experimental site the veto detector prototype achieved a baseline resolution of 1.24 $\pm$ 0.02 keV while hosting a functional inner target detector. The baseline resolution of the inner target detector was 147 $\pm$ 2 eV. The detectors were operated at mK temperatures. The experimental results of an identical detector arrangement are in excellent agreement with the simulation.

physics.ins-det

Constraints on Lightly Ionizing Particles from CDMSlite

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than $e/(3\times10^5$), as well as the strongest limits for charge $\leq e/160$, with a minimum vertical intensity of $1.36\times10^{-7}$\,cm$^{-2}$s$^{-1}$sr$^{-1}$ at charge $e/160$. These results apply over a wide range of LIP masses (5\,MeV/$c^2$ to 100\,TeV/$c^2$) and cover a wide range of $βγ$ values (0.1 -- $10^6$), thus excluding non-relativistic LIPs with $βγ$ as small as 0.1 for the first time.

hep-ex

Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground

We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σ_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matter particle masses from $93$ to $140$ $\mathrm{MeV}/c^2$, with a raw exposure of $9.9$ $\mathrm{g}\cdot\mathrm{d}$ acquired at an above-ground facility. This work illustrates the scientific potential of detectors with athermal phonon sensors with eV-scale energy resolution for future dark matter searches.

hep-ex

Large-mass single-electron-resolution detector for dark matter and neutrino elastic interaction searches

Large mass single-electron-resolution solid state detectors are desirable to search for low mass dark matter candidates and to measure coherent elastic neutrino nucleus scattering (CE$ν$NS). Here, we present results from a novel 100 g phonon-mediated Si detector with a new interface architecture. This detector gives a baseline resolution of $\sim 1 e^{-}/h^{+}$ pair and a leakage current on the order of $10^{-16}$ A. This was achieved by removing the direct electrical contact between the Si crystal and the metallic electrode, and by increasing the phonon absorption efficiency of the sensors. The phonon signal amplification in the detector shows a linear increase while the signal to noise ratio improves with bias voltage, up to 240 V. This feature enables the detector to operate at a low energy threshold which is beneficial for dark matter and CE$ν$NS like searches.

physics.ins-det

Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector

This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 gram-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section $\barσ_{e}$ is constrained for dark matter masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50 eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90% confidence-level upper limits within the above mentioned mass ranges are $\barσ_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$, $\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.

hep-ex

Constraints on dark photons and axion-like particles from SuperCDMS Soudan

We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 500 eV/$c^2$ for both candidates, excluding previously untested parameter space for masses below ~1 keV/$c^2$. For the kinetic mixing of dark photons, values below $10^{-15}$ are reached for particle masses around 100 eV/$c^2$; for the axioelectric coupling of axion-like particles, values below $10^{-12}$ are reached for particles with masses in the range of a few-hundred eV/$c^2$.

hep-ex

Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than was used for the two previous CDMSlite data sets. This analysis includes a data "salting" method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$ cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous CDMSlite result.

astro-ph.CO

Phonon-mediated High-voltage Detector with Background Rejection for Low-mass Dark Matter and Reactor Coherent Neutrino Scattering Experiments

We report the first demonstration of a phonon-mediated silicon detector technology that provides a primary phonon measurement in a low-voltage region, and a simultaneous indirect measurement of the ionization signal through Neganov-Trofimov-Luke amplification in a high voltage region, both in a monolithic crystal. We present characterization of charge and phonon transport between the two stages of the detector and the resulting background discrimination capability at low energies. This new detector technology has the potential to significantly enhance the sensitivity of dark matter and coherent neutrino scattering experiments beyond the capabilities of current technologies that have limited discrimination at low energies.

physics.ins-det

Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in Germanium with CDMSlite

Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected production rates, and analyze data from the second run of the CDMS low ionization threshold experiment (CDMSlite) to estimate the rates for several isotopes. We model the measured CDMSlite spectrum and fit for contributions from tritium and other isotopes. Using the knowledge of the detector history, these results are converted to cosmogenic production rates at sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H, 1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.

physics.ins-det

Performance of the First 150 mm Diameter Cryogenic Silicon Ionization Detectors with Contact-Free Electrodes

Cryogenic semiconductor detectors operated at temperatures below 100 mK are commonly used in particle physics experiments searching for dark matter. The largest such germanium and silicon detectors, with diameters of 100 mm and thickness of 33 mm, are planned for use by the Super Cryogenic Dark Matter Search (SuperCDMS) experiment at SNOLAB, Canada. In order to scale up the sensitive mass of future experiments, larger individual detectors are being investigated. We present here the first results of testing two prototype 150 mm diameter silicon ionization detectors. The detectors are 25 mm and 33 mm thick with masses 1.7 and 2.2 times larger than those currently planned for SuperCDMS. These devices were operated with contact-free bias electrodes to minimize leakage currents which currently limit operation at high bias voltages. One detector was instrumented to read out ionization signals using a single contact-free readout electrode and the other with an array of electrodes patterned on the crystal surface. The results show promise for the use of both large volume silicon detectors and contact-free electrode arrangements for scaling up solid state cryogenic detector mass and bias voltage.

physics.ins-det