SearcharxivSearch

arXiv subjects

A. K. Saha

Publications and source records attributed to A. K. Saha.

8 recordsLinked to original sources

First (calibration) experiment using proton beam from FRENA at SINP

This work presents the first calibration experiment of a 3 MV Tandetron accelerator, FRENA, performed in May 2022. The $^7$Li(p,n) reaction threshold was measured to calibrate the terminal voltage measuring device. A LiF target of thickness 175 $μ$g/cm$^2$ was used in the experiment. The measured threshold was 1872$\pm$2.7 keV, indicating 6$-$10 keV energy shift.

physics.ins-det

Study of $^{113}$In($α,α$) elastic scattering to determine $α$-optical potential relevant for astrophysical $γ$-process

The $α$-optical potential is one of the key input parameters used to measure the reaction rate of the ($γ,α$)-process using the Hauser-Feshbach(HF) statistical model and the principle of detailed balance. $α$-elastic scattering experiment on $^{113}$In $p$-nucleus was carried out in the energy range E$_{lab}$=26$-$32 MeV. The vacuum evaporation technique was used to prepare the $^{113}$In target~($\sim$86 $μ$g/cm$^2$). An energy-dependent local optical potential parameters set was obtained by analysing the experimental elastic scattering angular distribution data. The local potential parameters are extrapolated for lower energies and are used to measure the $^{113}$In($α,γ$) reaction cross-section.

nucl-ex

Detailed investigation on the possibility of using EJ-299-33A plastic scintillator for fast neutron spectroscopy in large scale experiments

Detailed characterization of the newly available plastic scintillator (EJ-299-33A) having the pulse shape discrimination (PSD) property has been carried out in case of a large-sized detector (5 in.$\times$5 in.). The pulse height response of the scintillator for nearly mono-energetic neutrons has been reported in case of neutron energies E$_n$ =3, 6 and 9 MeV. Important properties (figure-of-merit (FOM), time resolution, detection efficiency) of the detector has been compared with a commonly used liquid organic scintillator based detector of the same size coupled to the same PMT for uniformity in comparison. The results show that the plastic scintillator detector has about 12$\%$ better time resolution. However, the FOM and detection efficiency were found to be lower than that of the liquid scintillator detector by 40 - 50$\%$ and $\sim $25$\%$, respectively. The possibility of using the new plastic scintillator in large-scale nuclear physics experiments has been pointed out.

physics.ins-det

The determination of α-spectroscopic factors and ANC of 16O states using 12C(20Ne,16O)16O reaction at Elab=150 MeV incident energy

The 12C(20Ne,16O)16O α-transfer reaction at Elab=150 MeV is first time used to determine the ANC of the 6.92 MeV and 7.12 MeV states of 16O. The 20Ne+ 12C potential parameters are also obtained from elastic scattering. The direct reaction code FRESCO is used to determine the α-spectroscopy factor (Sα ) of the three states of 16O (6.92 MeV, 7.12 MeV and 11.52 MeV) and ANC of the two states (6.92 MeV and 7.12 MeV) of 16O. The extracted ANC and Sα are compareable to previous measurements.

nucl-ex

ChAKRA : The high resolution charged particle detector array at VECC

A large 4$π$ array of charged particle detectors has been developed at Variable Energy Cyclotron Centre to facilitate high resolution charged particle reaction and spectroscopy studies by detecting event-by-event the charged reaction products emitted in heavy ion reactions at energy $\sim$ 10-60 MeV/A. The forward part ($θ\sim \pm $ $7^{0}$ - $\pm 45^{0}$) of the array consists of 24 highly granular, high resolution charged particle telescopes, each of which is made by three layers [single sided silicon strip($Δ$E) + double sided silicon strip (E/$Δ$E) + CsI(Tl)(E)]of detectors. The backward part of the array consists of 112 CsI(Tl) detectors which are capable of detecting primarily the light charged particles (Z $\le$ 2) emitted in the angular range of $θ\sim \pm $ $45^{0}$ - $\pm 175^{0}$. The extreme forward part of the array ($θ\sim \pm $ $3^{0}$ - $\pm 7^{0}$) is made up of 32 slow-fast plastic phoswich detectors that are capable of detecting light (Z $\le$2) and heavy charged particles (3 $\le$ Z $\lesssim$ 20) as well as handling high count rates. The design, construction and characterization of the array has been described.

physics.ins-det

Study of $^{26}$Mg through 1p pick up reaction $^{27}$Al(d,$^{3}$He)

The even-even nucleus $^{26}$Mg has been studied through the reaction $^{27}$Al(d,$^{3}$He) at 25 MeV beam energy. The spectroscopic factors have been extracted upto 7.50 MeV excitation energy using local, zero range distorted wave Born approximation. The comparison of the spectroscopic factors have been done with previously reported values using the same reaction probe. The extracted spectroscopic factors for different excited states were found to be in good agreement with the previously reported values for the same. The present results were also compared with the predictions from shell model as well as rotational model. The analog states of $^{26}$Al and $^{26}$Mg were found to be in good agreement.

nucl-ex

No influence of a N=126 Neutron Shell Closure in Fission Fragment Mass Distributions

Mass distributions of the fragments in the fission of $^{206}$Po and the N=126 neutron shell closed nucleus $^{210}$Po have been measured. No significant deviation of mass distributions has been found between $^{206}$Po and $^{210}$Po, indicating the absence of shell correction at the saddle point in both the nuclei, contrary to the reported angular anisotropy and pre-scission neutron multiplicity results. This new result provides benchmark data to test the new fission dynamical models to study the effect of shell correction on the potential energy surface at saddle point.

nucl-ex

Interaction of magnetic-dipolar modes with microwave-cavity electromagnetic fields

We discuss the problem of magnetic-dipolar oscillations combined with microwave resonators. The energy density of magnetic-dipolar or magnetostatic (MS) oscillations in ferrite resonators is not the electromagnetic-wave density of the energy and not the exchange energy density as well. This fact reveals very special behaviors of the geometrical effects. Compared to other geometries, thin-film ferrite disk resonators exhibit very unique interactions of MS oscillations with the cavity electromagnetic fields. MS modes in a flat ferrite disk are characterized by a complete discrete spectrum of energy levels. The staircase demagnetization energy in thin-film ferrite disks may appear as noticeable resonant absorption of electromagnetic radiation. Our experiments show how the environment may cause decoherence for magnetic oscillations. Another noticeable fact is experimental evidence for eigen-electric-moment oscillations in a ferrite disk resonator.

cond-mat.mes-hall