SearcharxivSearch

arXiv subjects

A. K. Yi

Publications and source records attributed to A. K. Yi.

8 recordsLinked to original sources

DMRadio-Core: A new approach for GUT-scale axion searches

Searches for QCD axions with masses in the neV/$c^2$ mass range are strongly motivated by new physics at the GUT scale and by well-motivated pre-inflationary axion symmetry breaking scales. This parameter space is challenging to probe due to the small axion-photon couplings, which typically require large, high-field magnets with substantial stored energy. In this paper, we propose a new experimental geometry based on a narrow-bore, segmented solenoid that optimizes the collection of the axion-induced signal using LC resonators outside the high-field region of the magnet bore. This alternative optimization significantly reduces the required stored magnetic energy while preserving sensitivity, enabling a near-term experiment in the 30-200 MHz (120-830 neV/$c^2$) range, with a cost-effective, staged scaling to a GUT-scale experiment in the 100 kHz-30 MHz (0.4-120 neV/$c^2$) range.

hep-ex

The Cryogenic System of DMRadio-50L

The DMRadio-50L experiment is designed to search for axion dark matter in the 5 kHz - 5 MHz frequency range using a lumped-element LC resonator and a toroidal magnet and to serve as a testbed for quantum sensors. This paper describes the custom cryogenic system developed to meet the stringent requirements of the experiment within a standard laboratory environment. The system is designed to cool a 200 kg detector assembly to temperatures as low as 50 mK while providing sufficient cooling power at multiple temperature stages. We present the conceptual design, technical implementation, and measured performance of the hybrid cryogenic system, which combines a horizontal dilution refrigerator with a large vertical payload cryostat.

physics.ins-det

Electromagnetic modeling and science reach of DMRadio-m$^3$

DMRadio-m$^3$ is an experiment that is designed to be sensitive to KSVZ and DFSZ QCD axion models in the 10--200\,MHz (41 neV$/c^2$ -- 0.83 $μ$eV/$c^2$) range. The experiment uses a solenoidal dc magnetic field to convert an axion dark-matter signal to an ac electromagnetic response in a coaxial copper pickup. The current induced by this axion signal is measured by dc SQUIDs. In this work, we present the electromagnetic modeling of the response of the experiment to an axion signal over the full frequency range of DMRadio-m$^3$, which extends from the low-frequency, lumped-element limit to a regime where the axion Compton wavelength is only a factor of two larger than the detector size. With these results, we determine the live time and sensitivity of the experiment. The primary science goal of sensitivity to DFSZ axions across 30--200 MHz can be achieved with a $3σ$ live scan time of 2.9 years.

hep-ex

Noise limits for dc SQUID readout of high-$Q$ resonators below 300 MHz

We present the limits on noise for the readout of cryogenic high-$Q$ resonators using dc Superconducting Quantum Interference Devices (SQUIDs) below 300 MHz. This analysis uses realized first-stage SQUIDs (previously published), whose performance is well described by Tesche-Clarke (TC) theory, coupled directly to the resonators. We also present data from a prototype second-stage dc SQUID array designed to couple to this first-stage SQUID as a follow-on amplifier with high system bandwidth. This analysis is the first full consideration of dc SQUID noise performance referred to a high-$Q$ resonator over this frequency range, and is presented relative to the standard quantum limit. We include imprecision, backaction, and backaction-imprecision noise correlations from TC theory, the noise contributed by the second-stage SQUIDs, wiring, and preamplifiers, and optimizations for both on-resonance measurements and off-resonance scan sensitivity. This architecture has modern relevance due to the increased interest in axion searches and the requirements of the DMRadio-m$^3$ axion search, which will use dc SQUIDs in this frequency range.

quant-ph

Improved Receiver Noise Calibration for ADMX Axion Search: 4.54 to 5.41 $μ$eV

Axions are a well-motivated candidate for dark matter. The preeminent method to search for axion dark matter is known as the axion haloscope, which makes use of the conversion of axions to photons in a large magnetic field. Due to the weak coupling of axions to photons however, the expected signal strength is exceptionally small. To increase signal strength, many haloscopes make use of resonant enhancement and high gain amplifiers, while also taking measures to keep receiver noise as low as possible such as the use of dilution refrigerators and ultra low-noise electronics. In this paper we derive the theoretical noise model based on the sources of noise found within a typical axion haloscope receiver chain, using the Axion Dark Matter eXperiment (ADMX) as a case study. We present examples of different noise calibration measurements at 1280~MHz taken during ADMX's most recent data-taking run. These new results shed light on a previously unidentified interaction between the cavity and JPA, as well as provide a better understanding of the systematic uncertainty on the system noise temperature used in the axion search analysis for this data-taking run. Finally, the consistency between the measurements and the detailed model provide suggestions for future improvements within ADMX and other axion haloscopes to reach a lower noise temperature.

hep-ex

Enhanced tunable cavity development for axion dark matter searches using a piezoelectric motor in combination with gears

Most search experiments sensitive to quantum chromodynamics (QCD) axion dark matter benefit from microwave cavities, as electromagnetic resonators, that enhance the detectable axion signal power and thus the experimental sensitivity drastically. As the possible axion mass spans multiple orders of magnitude, microwave cavities must be tunable and it is desirable for the cavity to have a tunable frequency range that is as wide as possible. Since the tunable frequency range generally increases as the dimension of the conductor tuning rod increases for a given cylindrical conductor cavity system, we developed a cavity system with a large dimensional tuning rod in order to increase this. We, for the first time, employed not only a piezoelectric motor, but also gears to drive a large and accordingly heavy tuning rod, where such a combination to increase driving power can be adopted for extreme environments as is the case for axion dark matter experiments: cryogenic, high-magnetic-field, and high vacuum. Thanks to such higher power derived from the piezoelectric motor and gear combination, we realized a wideband tunable cavity whose frequency range is about 42\% of the central resonant frequency of the cavity, without sacrificing the experimental sensitivity too much.

hep-ph

Analytical estimation of the signal to noise ratio efficiency in axion dark matter searches using a Savitzky-Golay filter

The signal to noise ratio efficiency $ε_{\rm SNR}$ in axion dark matter searches has been estimated using large-statistic simulation data reflecting the background information and the expected axion signal power obtained from a real experiment. This usually requires a lot of computing time even with the assistance of powerful computing resources. Employing a Savitzky-Golay filter for background subtraction, in this work, we estimated a fully analytical $ε_{\rm SNR}$ without relying on large-statistic simulation data, but only with an arbitrary axion mass and the relevant signal shape information. Hence, our work can provide $ε_{\rm SNR}$ using minimal computing time and resources prior to the acquisition of experimental data, without the detailed information that has to be obtained from real experiments. Axion haloscope searches have been observing the coincidence that the frequency independent scale factor $ξ$ is approximately consistent with the $ε_{\rm SNR}$. This was confirmed analytically in this work, when the window length of the Savitzky-Golay filter is reasonably wide enough, i.e., at least 5 times the signal window.

astro-ph.IM

Fast DAQ system with image rejection for axion dark matter searches

A fast data acquisition (DAQ) system for axion dark matter searches utilizing a microwave resonant cavity, also known as axion haloscope searches, has been developed with a two-channel digitizer that can sample 16-bit amplitudes at rates up to 180 MSamples/s. First, we realized a practical DAQ efficiency of greater than 99% for a single DAQ channel, where the DAQ process includes the online fast Fourier transforms (FFTs). Using an IQ mixer and two parallel DAQ channels, we then also implemented a software-based image rejection without losing the DAQ efficiency. This work extends our continuing effort to improve the figure of merit in axion haloscope searches, the scanning rate.

physics.ins-det