SearcharxivSearch

arXiv subjects

A. Komives

Publications and source records attributed to A. Komives.

15 recordsLinked to original sources

Measurement of the Free Neutron Lifetime in a Magneto-Gravitational Trap with In Situ Detection

Here we publish three years of data for the UCNtau experiment performed at the Los Alamos Ultra Cold Neutron Facility at the Los Alamos Neutron Science Center. These data are in addition to our previously published data. Our goals in this paper are to better understand and quantify systematic uncertainties and to improve the lifetime statistical precision. We report a measured value for these runs from 2020-2022 for the neutron lifetime of 877.94+/-0.37 s; when all the data from UCNtau are averaged we report an updated value for the lifetime of 877.82+/-0.22 (statistical)+0.20-0.17 (systematic) s. We utilized improved monitor detectors, reduced our correction due to UCN upscattering on ambient gas, and employed four different main UCN detector geometries both to reduce the correction required for rate dependence and explore potential contributions due to phase space evolution.

nucl-ex

An experimental search for an explanation of the difference between beam and bottle neutron lifetime measurements

The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Here we publish an analysis of the recently published UCN aimed a searching for an explanation of this difference using the model proposed by Koch and Hummel.

nucl-ex

Recoil-Order and Radiative Corrections to the aCORN Experiment

The aCORN experiment measures the electron-antineutrino $a$-coefficient in free neutron decay. We update the previous aCORN results to include radiative and recoil corrections to first order, and discuss a key issue in the comparison of results from different $a$-coefficient experimental methods when these effects are considered. The corrected combined result is $\overline{a} = -0.10779 \pm 0.00125\, ({\rm stat}) \pm 0.00133\, ({\rm sys})$, averaged over the full Fermi neutron beta spectrum. The corresponding corrected result for the ratio of weak coupling constants $λ= G_A/G_V$ is $λ= -1.2712 \pm 0.0061$. This improves agreement with previous $a$-coefficient experiments, in particular the 2020 aSPECT result

nucl-ex

Fundamental Neutron Physics: a White Paper on Progress and Prospects in the US

Fundamental neutron physics, combining precision measurements and theory, probes particle physics at short range with reach well beyond the highest energies probed by the LHC. Significant US efforts are underway that will probe BSM CP violation with orders of magnitude more sensitivity, provide new data on the Cabibbo anomaly, more precisely measure the neutron lifetime and decay, and explore hadronic parity violation. World-leading results from the US Fundamental Neutron Physics community since the last Long Range Plan, include the world's most precise measurement of the neutron lifetime from UCN$τ$, the final results on the beta-asymmetry from UCNA and new results on hadronic parity violation from the NPDGamma and n-${^3}$He runs at the FNPB (Fundamental Neutron Physics Beamline), precision measurement of the radiative neutron decay mode and n-${}^4$He at NIST. US leadership and discovery potential are ensured by the development of new high-impact experiments including BL3, Nab, LANL nEDM and nEDM@SNS. On the theory side, the last few years have seen results for the neutron EDM from the QCD $θ$ term, a factor of two reduction in the uncertainty for inner radiative corrections in beta-decay which impacts CKM unitarity, and progress on {\it ab initio} calculations of nuclear structure for medium-mass and heavy nuclei which can eventually improve the connection between nuclear and nucleon EDMs. In order to maintain this exciting program and capitalize on past investments while also pursuing new ideas and building US leadership in new areas, the Fundamental Neutron Physics community has identified a number of priorities and opportunities for our sub-field covering the time-frame of the last Long Range Plan (LRP) under development. This white paper elaborates on these priorities.

nucl-ex

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalyses of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. The new measurement gives a free neutron lifetime of . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

nucl-ex

Improved neutron lifetime measurement with UCN$τ$

We report an improved measurement of the free neutron lifetime $τ_{n}$ using the UCN$τ$ apparatus at the Los Alamos Neutron Science Center. We counted a total of approximately $38\times10^{6}$ surviving ultracold neutrons (UCN) after storing in UCN$τ$'s magneto-gravitational trap over two data acquisition campaigns in 2017 and 2018. We extract $τ_{n}$ from three blinded, independent analyses by both pairing long and short storage-time runs to find a set of replicate $τ_{n}$ measurements and by performing a global likelihood fit to all data while self-consistently incorporating the $β$-decay lifetime. Both techniques achieve consistent results and find a value $τ_{n}=877.75\pm0.28_{\text{ stat}}+0.22/-0.16_{\text{ syst}}$~s. With this sensitivity, neutron lifetime experiments now directly address the impact of recent refinements in our understanding of the standard model for neutron decay.

nucl-ex

Measurement of the neutron decay electron-antineutrino angular correlation by the aCORN experiment

The aCORN experiment measures the neutron decay electron-antineutrino correlation ($a$-coefficient) using a novel method based on an asymmetry in proton time-of-flight for events where the beta electron and recoil proton are detected in delayed coincidence. We report the data analysis and result from the second run at the NIST Center for Neutron Research, using the high-flux cold neutron beam on the new NG-C neutron guide end position: $a = -0.10758 \pm 0.00136 (\mbox{stat}) \pm 0.00148 (\mbox{sys})$. This is consistent within uncertainties with the result from the first aCORN run on the NG-6 cold neutron beam. Combining the two aCORN runs we obtain $a = -0.10782 \pm 0.00124 (\mbox{stat}) \pm 0.00133 (\mbox{sys})$, which has an overall relative standard uncertainty of 1.7 \%. The corresponding result for the ratio of weak coupling constants $λ= G_A/G_V$ is $λ= -1.2796\pm 0.0062$.

nucl-ex

Neutron Polarimetry Using a Polarized 3He Cell for the aCORN Experiment

The neutron polarization of the NG-C beamline at the NIST Center for Neutron Research was measured as part of the aCORN neutron beta decay experiment. Neutron transmission through a polarized 3He spin filter cell was recorded while adiabatic fast passage (AFP) nuclear magnetic resonance (NMR) reversed the polarization direction of the 3He in an eight-step sequence to account for drifts. The dependence of the neutron transmission on the spin filter direction was used to calculate the neutron polarization. The time dependent transmission was fit to a model which included the neutron spectrum, and 3He polarization losses from spin relaxation and AFP-NMR. The polarization of the NG-C beamline was found to be ${\mid}P_\mathrm{n}{\mid} \leq 4\times 10^{-4}$ with 90 % confidence.

physics.ins-det

Monte Carlo Simulations of Trapped Ultracold Neutrons in the UCNτ Experiment

In the UCNτ experiment, ultracold neutrons (UCN) are confined by magnetic fields and the Earth's gravitational field. Field-trapping mitigates the problem of UCN loss on material surfaces, which caused the largest correction in prior neutron experiments using material bottles. However, the neutron dynamics in field traps differ qualitatively from those in material bottles. In the latter case, neutrons bounce off material surfaces with significant diffusivity and the population quickly reaches a static spatial distribution with a density gradient induced by the gravitational potential. In contrast, the field-confined UCN -- whose dynamics can be described by Hamiltonian mechanics -- do not exhibit the stochastic behaviors typical of an ideal gas model as observed in material bottles. In this report, we will describe our efforts to simulate UCN trapping in the UCNτ magneto-gravitational trap. We compare the simulation output to the experimental results to determine the parameters of the neutron detector and the input neutron distribution. The tuned model is then used to understand the phase space evolution of neutrons observed in the UCNτ experiment. We will discuss the implications of chaotic dynamics on controlling the systematic effects, such as spectral cleaning and microphonic heating, for a successful UCN lifetime experiment to reach a 0.01% level of precision.

physics.ins-det

Measurement of the electron-antineutrino correlation in neutron beta decay: aCORN experiment

The aCORN experiment uses a novel asymmetry method to measure the electron-antineutrino correlation (a-coefficient) in free neutron decay that does not require precision proton spectroscopy. aCORN completed two physics runs at the NIST Center for Neutron Research. The first run on the NG-6 beam line in 2013--2014 obtained the result a = 0.1090 +/- 0.0030 (stat) +/- 0.0028 (sys), a total uncertainty of 3.8%. The second run on the new NG-C high flux beam line promises an improvement in precision to <2%.

nucl-ex

Measurement of the neutron lifetime using an asymmetric magneto- gravitational trap and in situ detection

The precise value of the mean neutron lifetime, $τ_n$, plays an important role in nuclear and particle physics and cosmology. It is a key input for predicting the ratio of protons to helium atoms in the primordial universe and is used to search for new physics beyond the Standard Model of particle physics. There is a 3.9 standard deviation discrepancy between $τ_n$ measured by counting the decay rate of free neutrons in a beam (887.7 $\pm$ 2.2 s) and by counting surviving ultracold neutrons stored for different storage times in a material trap (878.5$\pm$0.8 s). The experiment described here eliminates loss mechanisms present in previous trap experiments by levitating polarized ultracold neutrons above the surface of an asymmetric storage trap using a repulsive magnetic field gradient so that the stored neutrons do not interact with material trap walls and neutrons in quasi-stable orbits rapidly exit the trap. As a result of this approach and the use of a new in situ neutron detector, the lifetime reported here (877.7 $\pm$ 0.7 (stat) +0.4/-0.2 (sys) s) is the first modern measurement of $τ_n$ that does not require corrections larger than the quoted uncertainties.

nucl-ex

aCORN: an experiment to measure the electron-antineutrino correlation coefficient in free neutron decay

We describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. The apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. Details of the method, apparatus, detectors, data acquisition, and data reduction scheme are presented, along with a discussion of the important systematic effects.

physics.ins-det

The aCORN Backscatter-Suppressed Beta Spectrometer

Backscatter of electrons from a beta spectrometer, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electron-antineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter veto detectors surrounds a plastic scintillator beta energy detector. The spectrometer contains an axial magnetic field gradient, so electrons are efficiently admitted but have a low probability for escaping back through the entrance after backscattering. The design, construction, calibration, and performance of the spectrometer are discussed.

physics.ins-det

A new method for measuring the neutron lifetime using an in situ neutron detector

The neutron lifetime is important in understanding the production of light nuclei in the first minutes after the big bang and it provides basic information on the charged weak current of the standard model of particle physics. Two different methods have been used to measure the neutron lifetime: disappearance measurements using bottled ultracold neutrons and decay rate measurements using neutron beams. The best measurements using these two techniques give results that differ by nearly 4 standard deviations. In this paper we describe a new method for measuring surviving neutrons in neutron lifetime measurements using bottled ultracold neutrons that provides better characterization of systematic uncertainties and enables higher precision than previous measurement techniques. We present results obtained using our method.

nucl-ex

A Backscatter-Suppressed Beta Spectrometer for Neutron Decay Studies

We describe a beta electron spectrometer for use in an upcoming experiment that will measure the beta-antineutrino correlation coefficient (a-coefficient) in neutron beta decay. Electron energy is measured by a thick plastic scintillator detector. A conical array of plastic scintillator veto detectors is used to suppress events where the electron backscattered. A Monte Carlo simulation of this device in the configuration of the a-coefficient experiment is presented. The design, construction, and testing of a full-scale prototype device is described. We discuss the performance of this spectrometer with respect to its suitability for the experiment.

nucl-ex