Searcharxiv⌕ Search

arXiv subjects

A. Konopelko

Publications and source records attributed to A. Konopelko.

54 records · Page 3Linked to original sources

Altitude Effect in Cherenkov Light Flashes of Low Energy Gamma-ray-induced Atmospheric Showers

At present the ground-based Very High Energy (VHE) gamma-ray astronomy is racing to complete construction of a number of modern gamma-ray detectors, i.e. CANGAROO III, MAGIC, H.E.S.S., and VERITAS. They should be fully operational in a year's time. After much debate, the further development of this gamma-ray astronomy in the foreseeable future must be widely anticipated to proceed with the designing and building of a new instrumentation, which is primarily intended for the further drastic reduction of the energy threshold in gamma-ray observations down to about 10 GeV. On the ground one can hardly reach such low energy thresholds without considerably larger, up to 30 m diameter, optical telescopes, which might be able to collect sufficient amount of Cherenkov light from the atmospheric gamma-ray showers of that low energy. If not taken off the ground entirely (like GLAST), then it seems to be profitable to mount future low energy Cherenkov telescopes at higher altitudes in the atmosphere in order that they will be able to detect substantially more unabsorbed Cherenkov light from a shower. There are a few sites up on the high mountains of roughly 5 km height worldwide, which can be used for such a venture. However, one has to remember that actual time profile, and in particular a two-dimensional distribution (image) of Cherenkov light flash from atmospheric gamma-ray showers, undergo a rapid change after an increase in the observational level. This paper briefly describes the results of a topological analysis of Cherenkov light images calculated at both conventional and desirable altitudes of 2.2 and 5 km above the sea, respectively. A discussion on major upgrades of image topology at high altitude is also given.

astro-ph↗

Observations of the Crab Nebula with the HEGRA system of IACTs in convergent mode using a topological trigger

Routine observations of the Crab Nebula for a total of about 250 hrs, performed with the HEGRA stereoscopic system of 5 imaging atmospheric Cerenkov telescopes in the standard operational mode, have proven the energy threshold of the system to be 500 GeV for small zenith angles (< 20 deg). A topological trigger applied along with the convergent observational mode allows to reduce noticeably the energy threshold of the system down to 350 GeV. Here we present the relevant Monte Carlo simulations as well as the analysis results of 15 hrs Crab Nebula data taken in such an observational mode. From the Crab Nebula data, the final energy threshold was found to be 350 GeV. The estimated gamma ray flux from the Crab Nebula above 350 GeV is (8.1 +- 0.1(stat) +- 0.2(syst)) 10^(-11) ph cm^(-2) s^(-1), which is consistent with recent measurements reported by the STACEE, CELESTE, CAT, and Whipple groups.

astro-ph↗

Monte Carlo studies on the sensitivity of the HEGRA imaging atmospheric Cerenkov telescope system in observations of extended gamma-ray sources

In this paper, we present the results of Monte Carlo simulations of atmospheric showers induced by diffuse gamma rays as detected by the high-energy gamma ray astronomy (HEGRA) system of five imaging atmospheric Cerenkov telescopes (IACTs). We have investigated the sensitivity of observations on extended gamma ray emission over the entire field of view of the instrument. We discuss a technique to search for extended gamma ray sources within the field of view of the instrument. We give estimates for HEGRA sensitivity of observations on extended TeV gamma ray sources.

astro-ph↗

Future Pulsar Observations with H.E.S.S

Since their discovery at radio wavelengths pulsars have been persistent targets for widespread multi-wave observations throughout optics, radio, X-rays, and high-energy gamma-rays. Observations with the EGRET gamma-ray telescope, on board Compton GRO satellite, confirmed the expectation of a pulsed high-energy emission up to a few GeV. Presently, at least seven objects are known as well established high-energy gamma-ray pulsars. A few of those emit gamma-rays well above 1 GeV. Forthcoming ground-based Cherenkov telescopes will enable observations of gamma-rays well below 100 GeV, finally reaching the yet unexplored energy gap at tens of GeV. H.E.S.S. (High Energy Stereoscopic System) is one of such instruments which is planned to be operational in 2004. Here I summarize the basic scientific motivations, the H.E.S.S. sensitivity, and the first targets for future pulsar observations at high energies from the ground.

astro-ph↗

Limits on Pulsar Parameters for Pulsed detections with H.E.S.S

The non-detection of pulsed sub-TeV gamma-rays from EGRET pulsars proves that the EGRET pulsed spectra of all gamma-ray pulsars should terminate at energies below a few hundred GeV. The spectrum of a typical integrated pulse profile predicted by the polar cap model resemble typically a hard component, followed by a super exponential cutoff between 1 MeV (PSR B1509-58) and tens of GeV (e.g. Crab, PSR B1951+32 etc). Using a topological trigger for the H.E.S.S. Telescope System in the non-imaging mode, we show that H.E.S.S. should be able to detect pulsed emission from PSR B1706-44 within a few hours if the cutoff energy is above 30 GeV as suggested by EGRET observations. The recently detected radio pulsar PSR J1837-0604 (pulsar period: 96 ms) associated with the unidentified EGRET source GeV J1837-06010 should also be detectable within a few hours if the source is pulsed and if its cutoff is similar to that of PSR B1706-44. H.E.S.S. should even be able to image middle-aged, low-multiplicity pulsars for which the mean photon energy is expected to be well above 10 GeV. Such observations should provide important constraints on the final evolutionary status of gamma-ray pulsars and millisecond pulsars in general.

astro-ph↗

Search for point sources and diffuse emission from the Galactic plane with the HEGRA-IACT-system

The HEGRA-IACT-system with a FoV of ~1.5 deg radius has been used for surveying one quater of the Galactic disc in respect to point sources, moderately extended sources and for diffuse emission in the energy range above 1 TeV. In total 140 h of good observation time were accumulated. No new source has been discoverd. Limits on the level of 20% or lower of the Crab flux on about 87 potential sources like SNR, Pulsars and EGRET sources are derived. A limit on the diffuse emission is given on the level of dPhi/dE(E=1 TeV) = 6.1 10^-15 ph cm-2 s-1 sr-1 Mev-1 resulting in a lower limit of 2.5 on the spectral index for the extrapolation of the meassured EGRET flux for the diffuse emission.

astro-ph↗

Prospects of observing pulsed radiation from gamma-ray pulsars with H.E.S.S

Observations and theoretical studies have demonstrated that the pulsed spectra of all gamma-ray pulsars terminate at energies below a few hundred GeV. In most cases we expect this cutoff energy E_o to be around 10 GeV. Only with next generation ground-based gamma-ray telescopes, which are expected to have non-zero trigger probabilities near 10 GeV, can we expect to detect pulsations. The large gamma-ray fluxes below E_o, together with the associated sharp pulse profiles, compensate for the lack of imaging capability near threshold. For H.E.S.S. we find that the pulsed component of PSR B1706-44 should be detectable near threshold, whereas the unidentified GeV EGRET sources should be detectable if the superexponential cutoff energy is larger that approximately 30 GeV for relatively hard pulsar photon spectra (~E^-1.5).

astro-ph↗

ALTAI: Computational code for the simulations of TeV air showers as observed with the ground-based imaging atmospheric Cherenkov telescopes

Ground-based atmospheric Cherenkov telescopes are proven to be effective instruments for observations of very high energy (VHE) gamma-radiation from celestial objects. For effective use of such technique one needs detailed Monte Carlo simulations of gamma-ray- and proton/nuclei-induced air showers in Earth atmosphere. Here we discuss in detail the algorithms used in the numerical code ALTAI developed particularly for the simulations of Cherenkov light emission from air showers of energy below 50 TeV. The specific scheme of sampling the charged particle transport in the atmosphere allows the performance of very fast and accurate simulations used for interpretation of the VHE gamma-ray observations.

astro-ph↗

On the optimum spacing of stereoscopic imaging atmospheric Cherenkov telescopes

For stereoscopic systems of imaging atmospheric Cherenkov telescopes (IACTs), a key parameter to optimize the sensitivity for VHE gamma-ray point sources is the intertelescope spacing. Using pairs of telescopes of the HEGRA IACT system, the sensitivity of two-telescope stereo IACT systems is studied as a function of the telescope spacing, ranging from 70 m to 140 m. Data taken during the 1997 outburst of Mrk 501 are used to evaluate both the detection rates before cuts, and the sensitivity for weak signals after cuts to optimize the significance of signals. Detection rates decrease by about 1/3 between the minimum and maximum spacing. The significance of signals is essentially independent of distance, in the range investigated.

astro-ph↗

Improved energy resolution for VHE gamma-ray astronomy with systems of Cherenkov telescopes

We present analysis techniques to improve the energy resolution of stereoscopic systems of imaging atmospheric Cherenkov telescopes, using the HEGRA telescope system as an example. The techniques include (i) the determination of the height of the shower maximum, which is then taken into account in the energy determination, and (ii) the determination of the location of the shower core with the additional constraint that the direction of the gamma rays is known a priori. This constraint can be applied for gamma-ray point sources, and results in a significant improvement in the localization of the shower core, which translates into better energy resolution. Combining both techniques, the HEGRA telescopes reach an energy resolution between 9% and 12%, over the entire energy range from 1 TeV to almost 100 TeV. Options for further improvements of the energy resolution are discussed.

astro-ph↗

Effectiveness of TeV Gamma-Ray Observations at Large Zenith Angles with a Stereoscopic System of Imaging Atmospheric Cherenkov Telescopes

The sensitivity of imaging atmospheric Cherenkov telescopes (IACTs) in TeV gamma-ray observations reachs its maximum at small zenith angles (< 30 degree) which provide the minimum attainable energy threshold of an instrument. However, for a specific telescope site a number of gamma-ray sources, or source candidates, can only be observed at much larger zenith angles (< 60 degree). Moreover the observations at large zenith angles allow to extend the observation time window for any object seen at small zenith angles, as well as to enlarge the dynamic energy range of an instrument towards the highest observable energies of gamma-rays. Based on Monte Carlo simulations we present here the results on the sensitivity of a stereoscopic system of 5 IACTs in observations at large zenith angles. We point out some important parameters of the telescope design which could substantially improve the efficiency of such observations with forthcoming IACT arrays like CANGAROO III, HESS and VERITAS.

astro-ph↗

Comparison of techniques to reconstruct VHE gamma-ray showers from multiple stereoscopic Cherenkov images

For air showers observed simultaneously by more than two imaging atmospheric Cherenkov telescopes, the shower geometry is overconstrained by the images and image information should be combined taking into account the quality of the images. Different algorithms are discussed and tested experimentally using data obtained from observations of Mkn 501 with the HEGRA IACT system. Most of these algorithms provide an estimate of the accuracy of the reconstruction of shower geometry on an event-by-event basis, allowing, e.g., to select higher-quality subsamples for precision measurements.

astro-ph↗

Performance of the Stereoscopic System of the HEGRA Imaging Air Cherenkov Telescopes: Monte Carlo Simulations & Observations

Based on the Monte Carlo simulations we have studied the performance of the HEGRA system of imaging air Cherenkov telescopes (IACTs) in its present configuration of 4 IACTs as well as in its future final configuration of 5 IACTs. Here we present the results on the basic characteristics of the IACT system which are used in the standard data analysis procedure, i.e., the collection areas, the detection rates, the angular resolution, the energy resolution, and the gamma/hadron-separation efficiency. By comparing several key Monte Carlo predictions with experimental results it is possible to check the accuracy of the simulations. The Monte Carlo results concerning hadron-nuclear showers are tested with the recorded cosmic ray events and the results concerning photon-induced showers are tested with a large data sample of gamma-rays observed from BL Lac object Mkn 501 during its high flaring activity in 1997. Summarizing the simulations and current observations we give the basic recommendations of using the instrument and the major values of its sensitivity.

astro-ph↗

Energy Spectrum of TeV Gamma-Rays from Crab Nebula

The Crab Nebula has been observed by the HEGRA stereoscopic system of 4 imaging air Cherenkov telescopes (IACTs) for about 100 hours from 1997 September to 1998 March. The recent detailed studies on the system performance give an energy threshold and an energy resolution for gamma-rays of 500 GeV and \~20 %, respectively. The Crab spectrum was measured with the IACTs system in a very broad energy range from 500 GeV to 25 TeV, using the observations at zenith angles up to 50 degree. The pure power-law spectrum in TeV gamma-rays constrains the physics parameters of the nebula environment as well as the models of photon emission.

astro-ph↗

The TeV spectrum of Mkn 501 as measured during the high state in 1997 by the HEGRA stereoscopic system of imaging air Cherenkov telescopes

The BL Lac object Mkn 501 has shown very high emission in TeV gamma-rays from March to October, 1997. During this period the source was continuously monitored with the HEGRA stereoscopic system of 4 imaging air Cherenkov telescopes for a total exposure time of 110 hours. The unprecedented statistics of about 38,000 TeV photons, combined with the good energy resolution of ~20 % over the entire energy range and with detailed simulations of the detector response, allowed a determination of the average energy spectrum from 500 GeV to 24 TeV. Although the gamma-ray flux varied strongly with time, the daily energy spectra remained rather constant in their shape. Therefore it is justified to derive a time averaged spectrum and thus to extend, for the first time, the spectral measurement well beyond 10 TeV. This TeV spectrum of Mkn 501 shows a gradual steepening which could be caused by a number of physical processes, such as a limited energy range of the radiating particles, intrinsic gamma-ray absorption inside the source, the Klein-Nishina effect (in the case of an inverse Compton origin of the radiation) and finally, an absorption of the TeV gamma-rays propagating in the intergalactic medium.

astro-ph↗

AGN sudies above 1.5 TeV with the HEGRA 5 m^2 Cherenkov Telescope (Sources observed: Mkn 421, Mkn 501, MS 0116+319, PKS 2209+236, NGC 315 and W Comae)

The HEGRA 5 m^2 air Cherenkov telescope (CT1) was used to search for gamma-ray emission above 1.5 TeV from a series of low redshift AGN (Mkn 421, Mkn 501, MS 0116+319, PKS 2209+236, NGC 315 and W Comae). Here we present results from a total of 383 hours of ON-source observations at zenith angles up to 35$^\circ$ made between February 1996 and April 1997 showing positive detections of Mkn 421 and Mkn 501 and upper limits on the other objects' emission. More recent results from observations of Mkn 421 und Mkn 501 will be added at the conference.

astro-ph↗

Detection of Gamma-Rays above 1.5 TeV from Mkn 501

A detection of TeV $γ$-rays from Mkn 501 is reported, based on observations made between March and August 1996 with the first HEGRA Cherenkov telescope (CT1). From the image analysis, 351 excess candidate $γ$-ray events are obtained from the 147 h dataset. The statistical significance of the excess is 5.2 $σ$. The average excess rate is $2.4 \pm 0.5$ h$^{-1}$ above the $\approx$ 1.5 TeV threshold of CT1. Under the assumption that the spectrum of Mkn 501 follows a power law we find a differential spectral index of 2.6$\pm0.5$ and obtain a time-averaged integral flux above 1.5 TeV of $2.3 (\pm0.4)_{Stat} (+1.5-0.6)_{Syst} \times 10^{-12}$ cm$^{-2}$s$^{-1}$. Comparison with our near contemporary observations of the Crab Nebula, used as a standard candle to test CT1 after upgrading to a 127 pixel camera, indicates that Mkn 501 has a spectrum similar to that of the Crab Nebula above 1.5 TeV. The integral flux above 1.5 TeV from Mkn 501 is found to have been between 2.2 and 3.6 times smaller than that from the Crab Nebula. HEGRA is the second experiment to have detected Mkn 501 in the TeV range.

astro-ph↗

Detection of VHE Gamma-rays from Mkn 421 with the HEGRA Cherenkov Telescopes

A detection of Gamma-rays from Mkn 421 at energies above 1 TeV is reported, based on observations made in December 1994 - May 1995 with the first two HEGRA Cherenkov telescopes. >From the image analysis, 111 excess gamma candidates are obtained from the 26 h Telescope #1 (CT1) dataset (significance 4.0 sigma) and 218 from the 41 h Telescope #2 (CT2) dataset (significance 4.2 sigma) at zenith angles theta < 25 degrees. The combined significance is approx. 5.8 sigma. This is the second detection of Mkn 421 at TeV energies. The average excess rate is 4.3 +- 1.0 h^-1 for CT1 and 5.4 +- 1.3 h^-1 for CT2. Comparison with our contemporary observations of the Crab Nebula indicates that Mkn 421 has a steeper spectrum than the Crab Nebula above 1 TeV. Under the assumption that the spectrum of Mkn 421 follows a power law, we obtain a differential spectral index of 3.6 +- 1.0 and an integral flux above 1 TeV of 8 (+-2)_(Stat) (+6-3)_(Syst) x 10^-12 cm^-2 s^-1 from a comparison with Monte Carlo data. This flux is smaller than the Crab Nebula flux by a factor of 2.0 +- 0.8.

astro-ph↗